Search NASA⌕ Search

Engineering topics

Kent, Edward

Publications and source records attributed to Kent, Edward.

Report on Initial Sodium Testing on the Thermal Hydraulic Experimental Test Article (THETA) (Fiscal Year 2024 Final Report)

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that is used to develop sodium components and instrumentation as well as to acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility simulates nominal thermal hydraulic conditions as well as protected/unprotected loss of flow accidents in a sodium-cooled fast reactor (SFR). High fidelity distributed temperature profiles of the developed flow field may be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility was designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. THETA is comprised of a traditional primary coolant and secondary coolant system. The primary system is submerged in the pool of sodium and consists of a pump, electrically heated core, intermediate heat exchanger, and connected piping and thermal barriers (redan). The secondary system, located outside of the sodium pool, consists of a pump, sodium to air heat exchanger, and connected piping and valves. In fiscal year 2023, thermal stratification tests were completed with the primary system online, while the secondary system was being constructed [1]. These tests had shown that the core barrel and intermediate heat exchanger (IHX) outlet required increased thermal insulation. The THETA primary system was removed from METL, cleaned, thermal insulators installed, and then inserted into METL Test Vessel 4. At the time of this writing the THETA primary and secondary system are operational. During this fiscal year 100+ hours of testing was completed to characterize thermal hydraulic phenomena associated with steady state and transient conditions in a pool type liquid metal cooled reactor. A majority of the testing campaign was completed to satisfy the experimental data acquisition requirements for the GAIN Voucher with Oklo, CRADA 2021-21121. THETA is still operational at the time of this publication and future testing is planned for fiscal year 2025. Work is underway to publish existing and future data to an online database to facilitate collaboration with SFR engineers looking to validate their systems code or computational fluid dynamics models.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Design Optimization and Measurement Uncertainty of an Electromagnetic Level Sensor for Liquid Metal Reactors

Here, this article describes the design and operation of a prototype mutual inductance level sensor (MILS) and the development and validation of a finite-element analysis (FEA) model describing its behavior. The MILS was designed for use in liquid sodium up to temperatures of 650 °C in the Mechanisms Engineering Test Loop (METL) at Argonne National Laboratory (ANL). Preliminary testing was performed in a room temperature test stand with aluminum acting as an analog for the sodium to better understand sensor performance and provide accurate code validation data. This experimental data, along with material properties found in literature, were used to validate an FEA model in ANSYS Maxwell. The validated ANSYS Maxwell model was used to examine the performance of the MILS in various environments and under various operating conditions. Simulations suggest the following: The MILS will perform adequately in liquid sodium and liquid lead at temperatures up to 650 °C . The temperature dependence of electrical conductivity imposes a temperature dependence on the sensor that requires proper compensation. The MILS signal sensitivity is maximized when mutual inductance between sensor coils is maximized, and sensor geometry should be selected to account for this factor. The operating frequency of the MILS can be optimized and is dependent on process fluid material, operating temperature, and materials/geometry of sensor system. Finally, the use of a stainless-steel isolating thimble does not adversely affect the sensor signal. The primary sources of error for this MILS system are the accuracy of the calibration standard against which the sensor is calibrated, and the temperature dependence of the sensor. This work contains all the necessary details to recreate the FEA model and results. This model can be used to optimize the performance of a MILS in any operating environment to read any electrically conductive working fluid.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Thermal Hydraulic Experimental Test Article - Fiscal Year 2023 (Final Report)

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that is used to develop sodium components and instrumentation as well as acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility simulates nominal conditions as well as protected/unprotected loss of flow accidents in a sodium-cooled fast reactor (SFR). High fidelity distributed temperature profiles of the developed flow field may be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility was designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. THETA is comprised of a traditional primary coolant and secondary coolant system. The primary system is submerged in the pool of sodium and consists of a pump, electrically heated core, intermediate heat exchanger, and connected piping and thermal barriers (redan). The secondary system, located outside of the sodium pool, consists of a pump, sodium to air heat exchanger, and connected piping and valves. To date a test matrix has been completed utilizing the primary system of THETA. These tests, along with computational fluid dynamics and systems code models, determined the heat transfer across the core barrel and intermediate heat exchanger outlet was too great to effectively represent scaled thermal hydraulic phenomena of a liquid metal cooled reactor. Therefore, a significant effort was made to remove the primary system from the METL 28” test vessel #4 and clean the residual sodium from the primary system to facilitate upgrades. Thermal insulation was then incorporated in the core barrel and intermediate heat exchanger outlets. The primary system was then replaced, and a series of tests were performed to assess the performance of the thermal insulation. With primary system testing and upgrades complete, the secondary system could then be brought online. The tube side of the shell-and-tube intermediate heat exchanger was installed onto the primary system flange to begin installing the secondary system. The support structure for the secondary system was then erected on the METL mezzanine alongside the THETA primary system to facilitate installation of the secondary system components (sodium-to-air heat exchanger, flowmeter and pump). The piping and expansion tank were welded into the secondary system. Non-destructive examination of the secondary system welds was completed in order to satisfy ASME B31.3 pipe code for class M process fluids. The heating system and insulation were then added to prepare the system to be filled with sodium. The ancillary electrical equipment was installed which included the pump control box, blower VFD, pipe heater control system, etc. The secondary system will be filled, and a test matrix will be completed in early FY2024.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Mechanisms Engineering Test Loop (METL) Operations and Testing Report (FY2022)

This report documents the operations, testing, maintenance, and improvements that were performed at the Mechanisms Engineering Test Loop (METL) during FY2022. The METL facility had a very successful fourth year of operations and went through some new experiences such as taking the facility from its frozen state in October 2021 and thawing the facility and also recovering from an oxide plug in one of the cold trap lines. After the facility was fully thawed, the METL staff maintained the facility in a continuous molten state – either flowing sodium or a static flow condition. METL facility continued supporting the Gear Test Assembly (GTA) testing and hosted its first 28” test vessel experiment, called the Thermal Hydraulic Experimental Test Article (THETA) which was inserted into Test Vessel 4. Work to accommodate two additional experiments, a gripper test article (GrTA) and a flow sensor test article (F-STAr) continued as they are expected to make their debut in FY2023. In addition, the steam piping for the B308 scrubber unit was replaced with stainless steel piping and controls and new parts for the scrubber were purchased – such as a new pump, new storage tank, and new blower and motor. These components will ultimately replace the existing scrubber components when those 1970’s era require replacement.

42 ENGINEERING↗