Comparison of the F2 Structure Function in Iron as Measured by cahrged Lepton and Neutrino Probes
Explore the source record for details and available documents.
Engineering topics
Publications and source records attributed to Keppel, Cynthia.
Explore the source record for details and available documents.
The interpretation of results from current and future neutrino oscillation experiments will necessitate precision descriptions of neutrino-nucleus interactions. The achievement of this goal requires a multidisciplinary effort, with nuclear physics providing input to properly constrain leading systematics. Collaboration between the electron and neutrino scattering communities has been developing to address this need. Beyond oscillation experiments, differences between electron and neutrino experiments can provide insight into nucleon and nuclear structure. This talk will highlight some recent and anticipated results from electron scattering experiments of direct relevance to neutrino data, as well as discuss some synergistic studies of interest to both communities.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
We present the first official release of the nCTEQ nuclear parton distribution functions with errors. The main addition to the previous nCTEQ PDFs is the introduction of PDF uncertainties based on the Hessian method. Another important addition is the inclusion of pion production data from RHIC that give us a handle on constraining the gluon PDF. This contribution summarizes our results from arXiv:1509.00792 and concentrates on the comparison with other groups providing nuclear parton distributions.
We present preliminary results of a new global QCD analysis of PDFs from the CTEQ-Jefferson Lab Collaboration (dubbed "CJ15"), which includes several new data sets and recent theoretical developments. In particular, we study the constraints from new D0 data on *W* boson asymmetries on the *d/u* PDF ratio at large *x*, and, indirectly, on the models of nuclear corrections in the deuteron. The analysis also considers for the first time the impact of Jefferson Lab data on the free neutron/deuteron structure function ratio at large *x*, and reanalyzes the light antiquark asymmetry in the proton from Drell-Yan data using more flexible parametrizations and nuclear corrections to deuterium cross sections. The results provide a new set of baseline PDFs which can be used to more reliably calibrate the effect of future data from the LHC.
Explore the source record for details and available documents.
The electromagnetic calorimeters of the various magnetic spectrometers in Hall C at Jefferson Lab are presented. For the existing HMS and SOS spectrometers design considerations, relevant construction information, and comparisons of simulated and experimental results are included. The energy resolution of the HMS and SOS calorimeters is better than $\sigma/E \sim 6%/\sqrt E $, and pion/electron ($\pi/e$) separation of about 100:1 has been achieved in energy range 1 -- 5 GeV. Good agreement has been observed between the experimental and simulated energy resolutions, but simulations systematically exceed experimentally determined $\pi^-$ suppression factors by close to a factor of two. For the SHMS spectrometer presently under construction details on the design and accompanying GEANT4 simulation efforts are given. The anticipated performance of the new calorimeter is predicted over the full momentum range of the SHMS. Good electron/hadron separation is anticipated by combining the energy deposited in an initial (preshower) calorimeter layer with the total energy deposited in the calorimeter.
An experiment with a newly developed high-resolution kaon spectrometer and a scattered electron spectrometer with a novel configuration was performed in Hall C at Jefferson Lab. The ground state of a neutron-rich hypernucleus, He Λ ⁷, was observed for the first time with the (e, e'K⁺) reaction with an energy resolution of ~0.6 MeV. This resolution is the best reported to date for hypernuclear reaction spectroscopy. The He Λ ⁷ binding energy supplies the last missing information of the A=7, T=1 hypernuclear isotriplet, providing a new input for the charge symmetry breaking effect of the ΛN potential.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
In 1946, physicist Robert Wilson first suggested that protons could be used as a form of radiation therapy in the treatment of cancer because of the sharp drop-off that occurs on the distal edge of the radiation dose. Research soon confirmed that high-energy protons were particularly suitable for treating tumors near critical structures, such as the heart and spinal column. The precision with which protons can be delivered means that more radiation can be deposited into the tumor while the surrounding healthy tissue receives substantially less or, in some cases, no radiation. Since these times, particle accelerators have continuously been used in cancer therapy and today new facilities specifically designed for proton therapy are being built in many countries. Proton therapy has been hailed as a revolutionary cancer treatment, with higher cure rates and fewer side effects than traditional X-ray photon radiation therapy. Proton therapy is the modality of choice for treating certain small tumors of the eye, head or neck. Because it exposes less of the tissue surrounding a tumor to the dosage, proton therapy lowers the risk of secondary cancers later in life - especially important for young children. To date, over 80,000 patients worldwide have been treated with protons. Currently, there are nine proton radiation therapy facilities operating in the United States, one at the Hampton University Proton Therapy Institute. An overview of the treatment technology and this new center will be presented.
We critically examine uncertainties in parton distribution functions (PDFs) at large x arising from nuclear effects in deuterium F2 structure function data. Within a global PDF analysis, we assess the impact on the PDFs from uncertainties in the deuteron wave function at short distances and nucleon off-shell effects, the use of relativistic kinematics, as well as the use of less a restrictive parametrization of the d/u ratio. We find that in particular the d-quark and gluon PDFs vary significantly with the choice of nuclear model. We highlight the impact of these uncertainties on the determination of the neutron structure function, and on W boson production and parton luminosity at the Tevatron and the LHC. Finally, we discuss prospects for new measurements sensitive to the d-quark and gluon distributions but insensitive to nuclear corrections.
While an impressive amount of high quality nucleon structure function data exists from hydrogen, deuterium, and other targets, the lack of a neutron target has made direct comparisons between proton and neutron structure functions nearly impossible at large x where nuclear effects become large. The behavior of the d quark as x approaches 1 is particularly sensitive to the deuterium corrections, and the impact on the parton distribution functions (PDFs) from uncertainties in the deuteron wave function at short distances, nucleon off-shell effects, the use of relativistic kinematics, as well as the use of less a restrictive parametrization of the d/u ratio have been evaluated within a global PDF analysis. These results will be discussed, as well as compared to those from the Barely Off-Shell Nucleon Structure (BONUS) Experiment. The BONUS experiment employed a novel radial time projection chamber to detect spectator protons resulting from electron-deuteron interactions in coincidence with electrons in the CEBAF Large Acceptance Spectrometer in Hall B at Jefferson Lab - thereby ensuring an inclusive electron-neutron scattering event. BONUS measured with beam energies from 1.1 to 5.3 GeV, focusing on the resonance and large x regimes. Final neutron structure function results from BONUS will be presented.
Purpose: To verify calculated water equivalent thickness (WET) and water equivalent spreadness (WES) in various tissue equivalent media for proton therapy Methods: Water equivalent thicknesses (WET) of tissue equivalent materials have been calculated using the Bragg-Kleeman rule. Lateral spreadness and fluence reduction of proton beams both in those media were calculated using proton loss model (PLM) algorithm. In addition, we calculated lateral spreadness ratios with respect to that in water at the same WET depth and so the WES was defined. The WETs of those media for different proton beam energies were measured using MLIC (Multi-Layered Ionization Chamber). Also, fluence and field sizes in those materials of various thicknesses were measured with ionization chambers and films Results: Calculated WETs are in agreement with measured WETs within 0.5%. We found that water equivalent spreadness (WES) is constant and the fluence and field size measurements verify that fluence can be estimated using the concept of WES. Conclusions: Calculation of WET based on the Bragg-Kleeman rule as well as the constant WES of proton beams for tissue equivalent phantoms can be used to predict fluence and field sizes at the depths of interest both in tissue equivalent media accurately for clinically available protonenergies.
Measurements of the proton and deuteron F 2 structure functions are presented. The data, taken at Jefferson Lab Hall C, span the four-momentum transfer range 0.06 2 <2.8GeV 2 and Bjorken x values from 0.009 to 0.45, thus extending the knowledge of F 2 to low values of Q 2 at low x. Next-to-next-to-leading-order calculations using recent parton distribution functions start to deviate from the data for Q 2 <2 GeV 2 at the low and high x values. Down to the lowest value of Q 2 , the structure function is in good agreement with a parametrization of F 2 based on data that have been taken at much higher values of Q 2 or much lower values of x, and which are constrained by data at the photon point. The ratio of the deuteron and proton structure functions at low x remains well described by a logarithmic dependence on Q 2 at low Q 2 .
Purpose: The validation of a novel approach for reducing skindoses to an acceptable level during Accelerated Partial Breast Irradiation (APBI) when the balloon-to-skin distance is inadequate (less than 7 mm) is reported. The study uses a real time dose verification method for a metallic shielded balloon applicator using scintillation fiber technology. Method and Materials: Partial shielding of the radiationdose to the skin using iron or other ferrous powder could enable the extension of APBI to some patients. With small external and pre-determined magnetic fields (<few Gauss), the metallic elements deposition can be controlled on the inner surface of a balloon. Geant4 simulations were used to generate an attenuation dose curve for various radiation lengths after cross-calibration with dedicated data acquired at Jefferson Lab. Some powder was then injected into various inflated MammoSite and rectal balloons within realistic breast and torso phantoms of differing sizes. The dose on the external surface of the skin was measured from a 6.1 Ci {sup 192}Ir of a GammaMed 12i afterloader unit, with a MOSFET,ion chamber and scintillating fiber array detectors. Results: Realistic Monte Carlo simulation studies for the amount and distribution of the required shielding material were compared to dedicated phantom data. A decrease of the skindose was measured to an acceptable level (~350-450 cGy) during standard breast Brachytherapy treatments with relatively weak magnetic fields. Additional measurements provided negligible corrections (< few %) on the saline water density from the suspended ironpowder.Conclusion: This project opens the possibility to increasing the survival expectancy and minimizing negative side effects during brachytherapy treatments, as well as improving cosmetic outcome for all APBI patients. The proposed method may also be used in other procedures for brain, heart, rectal, or vaginal cancers.