Lightning Flash Detection System (LFDS) is a viable solution for detecting cloud-to-ground lightning.
The LMA can pick up the smallest static discharge ongoing inside developing thunderstorms that could be the precursor to a future cloud-to-cloud or cloud-to-ground lightning strike. Research done at Pantex in 2020 of 20 different storms from February through November showed an average lead time of around 20 minutes from when “source densities” were detected inside developing thunderstorms over the Texas Panhandle to when the first cloud-to-cloud or cloud-to-ground lightning strike occurred.
Research done at Pantex in 2020 of 20 different storms from February through November showed an average lead time of around 20 minutes from when “source densities” were detected inside developing thunderstorms over the Texas Panhandle to when the first cloud-to-cloud or cloud-to-ground lightning strike occurred.
Using previous studies that showed that when a developing storm has a 35dbz radar echo at a height inside the cloud where the temperature drops to -10 degrees C, yields an estimated 85% chance of future lightning occurring, we put this storm that developed on 7/2/20 to the same parameters. The Pantex LMA (Lightning Mapping Array) detected “charge densities” at 13:56. These can be precursors to future lightning. The Pantex LMA picked these charge densities up 10 minutes after the 35 dbz core reached 25,000 feet.
These lightning strikes can be more dangerous than “normal” lightning associated with a regular thunderstorm in that the “bolts from the blue” often occur well away from where the precipitation is occurring at the surface. “Bolts from the blue” occurred at a measured distance of 33 miles and an estimated 35 to 50 miles away from where the precipitation was occurring with this storm.
Pantex’s LMA detects “flash pulses” at 15:47, or 16 minutes later. We had 64 minutes lead time between 35-40 dbz threshold being reached and the first CG lightning strike in this storm.
The storm appears to have reached a 35-40 dbz threshold around 17:55. Pantex’s LMA detects “flash densities” at 18:05, or 10 minutes later.
The storm appears to have reached a 35-40 dbz threshold around 22:04. Pantex’s LMA detects “flash densities” at 22:11, or 7 minutes later. The first intra-cloud (CC) and cloud-to-ground strikes occurred simultaneously at 22:17.
The storm developed along an outflow boundary. Daytime heating helped break two capping inversions noted on the morning weather balloon launch from KAMA. The storm appears to have reached a 35-40 dbz threshold quickly around 15:20. Pantex’s LMA detects “source densities” at 15:20. The first intra-cloud (CC) strikes occur simultaneously at 15:26 just west of 34th & Soncy. The first cloud-to-ground (CG) lightning strike occurred 7 minutes later at15:33 just west of Jason’s Deli (34th and Coulter Shopping Center).
A study on tropical showers that triggered “lightning warnings” at Pantex Plant