Search NASA⌕ Search

Engineering topics

Kertesz, Vilmos [ORNL] (ORCID:0000000301865797)

Publications and source records attributed to Kertesz, Vilmos [ORNL] (ORCID:0000000301865797).

Rapid Generation of Tandem Mass Spectrometry Reference Libraries Using Immediate Drop-on-Demand Liquid Handling Coupled to an Open Port Sampling Interface

In metabolomics, tandem MS (MS2) fragmentation libraries are important for the identification of unknown features, but generating these libraries takes many valuable hours of instrument and operator time. Here, an immediate droplet-on-demand/open port sampling interface was used to rapidly acquire tandem MS of standards arrayed in a 96-well plate format. A workflow was developed for automated, high-throughput control of MS2 library generation. Pure standard mass spectral libraries were collected on Orbitrap and Q-TOF mass spectrometers for 192 compounds using 6 different collision energies with a throughput of 4 and 7.8 s/spectrum, respectively. Libraries were acquired using different solvent additives, precursor adducts, and ion polarities.

Cahill, John [ORNL] (ORCID:0000000298664010)↗

Comparing Liquid Vortex Capture & the Rapid Droplet Sampling Interface for Single Cell Mass Spectrometry

High-throughput single-cell mass spectrometry is a rapidly evolving field that requires innovative sampling and ionization techniques to balance speed, sensitivity, and reliability for metabolomic and lipidomic analyses. This study provides a comparative analysis of two cutting-edge ionization platforms for single-cell analysis: Liquid Vortex Capture (LVC) and Rapid Droplet Sampling Interface (RDSI). The performance was benchmarked by testing pharmaceuticals, EquiSPLASH, and single-cell experiments. RDSI demonstrated up to 100-fold improvements in sensitivity for drugs and lipids such as propranolol, amiodarone, atorvastatin, and phosphocholines in water and phosphate-buffered solutions. This was attributed to its low-flow rate operation (3 μL/min) and reduced dilution. Conversely, LVC excelled in handling higher liquid volumes with greater reproducibility due to its higher solvent flow rate (200 μL/min), enabling increased dilution, solubility, and cleaning. Single-cell uptake of atorvastatin incubated for 10 min, or amiodarone incubated for 24 h in HepG2 cells, similarly revealed up to 85-fold enhancement in sensitivity by RDSI for drugs and lipids. These findings highlight the potential of RDSI for enhancing sensitivity in single-cell drug monitoring and lipidomics.

Cahill, John [ORNL] (ORCID:0000000298664010)↗

Upcycling of polyethylene terephthalate to high-value chemicals by carbonate-interchange deconstruction

Condensation thermoplastics have become ubiquitous. The emergence of chemical upcycling could transform them into valuable feedstocks for chemical manufacturing at their end-of-life. However, current solvolysis processes suffer equilibrium limitations due to the liberation of reactive byproducts. We report a carbonate interchange deconstruction (CID) methodology for poly(ethylene terephthalate) (PET), where carbonates act as both latent nucleophiles and byproduct sequestering agents. High product selectivity (>95%) is achieved regardless of the targeted terephthalate product, originating from removal of ethylene glycol from the reaction equilibrium via its conversion into various oligoethers. CID is robust to the impurities present in post-consumer waste plastics and significantly reduces solvent demand, with just 10 mL of dimethyl carbonate successfully converting ca. 5 g of mixed PET waste into highly pure dimethyl terephthalate in excellent isolated yield (92%). CID opens a new upcycling paradigm wherein CO2, embedded in carbonates, is leveraged to choreograph the selectivity of an otherwise equilibrium-controlled polymer upcycling process.

Galan, Nick [ORNL]↗