Search NASA⌕ Search

Engineering topics

Kesterson, M

Publications and source records attributed to Kesterson, M.

COMSOL MULTIPHYSICS MODEL FOR DWPF CANISTER FILLING, REVISION 1

This revision is an extension of the COMSOL Multiphysics model previously developed and documented to simulate the temperatures of the glass during pouring a Defense Waste Processing Facility (DWPF) canister. In that report the COMSOL Multiphysics model used a lumped heat loss term derived from experimental thermocouple data based on a nominal pour rate of 228 lbs./hr. As such, the model developed using the lumped heat loss term had limited application without additional experimental data. Therefore, the COMSOL Multiphysics model was modified to simulate glass pouring and subsequent heat input which, replaced the heat loss term in the initial model. This new model allowed for changes in flow geometry based on pour rate as well as the ability to increase and decrease flow and stop and restart flow to simulate varying process conditions. A revised COMSOL Multiphysics model was developed to predict temperatures of the glass within DWPF canisters during filling and cooldown. The model simulations and experimental data were in good agreement. The largest temperature deviations were {approx} 40 C for the 87 inch thermocouple location at 3000 minutes and during the initial cool down at the 51 inch location occurring at approximately 600 minutes. Additionally, the model described in this report predicts the general temperature trends during filling and cooling as observed experimentally. The revised model incorporates a heat flow region corresponding to the glass pouring down the centerline of the canister. The geometry of this region is dependent on the flow rate of the glass and can therefore be used to see temperature variations for various pour rates. The equations used for this model were developed by comparing simulation output to experimental data from a single pour rate. Use of the model will predict temperature profiles for other pour rates but the accuracy of the simulations is unknown due to only a single flow rate comparison.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

COMSOL MULTIPHYSICS MODEL FOR DWPF CANISTER FILLING

The purpose of this work was to develop a model that can be used to predict temperatures of the glass in the Defense Waste Processing Facility (DWPF) canisters during filling and cooldown. Past attempts to model these processes resulted in large (>200K) differences in predicted temperatures compared to experimentally measured temperatures. This work was therefore intended to also generate a model capable of reproducing the experimentally measured trends of the glass/canister temperature during filling and subsequent cooldown of DWPF canisters. To accomplish this, a simplified model was created using the finite element modeling software COMSOL Multiphysics which accepts user defined constants or expressions to describe material properties. The model results were compared to existing experimental data for validation. A COMSOL Multiphysics model was developed to predict temperatures of the glass within DWPF canisters during filling and cooldown. The model simulations and experimental data were in good agreement. The largest temperature deviations were {approx}40 C for the 87inch thermocouple location at 3000 minutes and during the initial cooldown at the 51 inch location occurring at approximately 600 minutes. Additionally, the model described in this report predicts the general trends in temperatures during filling and cooling observed experimentally. However, the model was developed using parameters designed to fit a single set of experimental data. Therefore, Q-loss is not currently a function of pour rate and pour temperature. Future work utilizing the existing model should include modifying the Q-loss term to be variable based on flow rate and pour temperature. Further enhancements could include eliminating the Q-loss term for a user defined convection where Navier-Stokes does not need to be solved in order to have convection heat transfer.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗