Kevin A Twedt

Publications and source records attributed to Kevin A Twedt.

Terra and Aqua MODIS Collection 7 Level 1B Algorithm

MODIS continues to be an important instrument for NASA’s Earth Observing System (EOS). Terra and Aqua MODIS have produced more than 22 and 20 years of global datasets that have significantly helped scientists better understand the Earth’s systems respectively. The MODIS Level-1B (L1B) algorithms use the uncalibrated, geolocated Earth scene observations as input and convert the instrument response into calibrated reflectance and radiance, which are used to generate the downstream science products. The sustained calibration and characterization activities undertaken by the MODIS Characterization Support Team have resulted in several upgrades to the L1B algorithms in order to maintain accurate calibration in the data products. In this paper, we present an overview of the L1B algorithm designated as Collection 7. Various algorithm enhancements both in the reflective bands and thermal bands characterization, are currently under science testing and evaluation. Once applied in data processing (projected in early 2023), they are expected to manifest in improved science products, both in terms of radiometric accuracy and long-term stability.

MODIS↗

Terra MODIS Sees Solar Eclipses: Analysis of Reflective Solar Band Response at Multiple Radiance Levels

The MODIS imaging spectroradiometer instruments on-board NASA's Terra and Aqua satellites have 20 reflective solar bands (RSB) covering a wavelength range from 400 to 2200 nm. Radiance is calculated from processing raw signals with background, temperature, and electronic contamination corrected. Measured gain is calibrated with a fully Sunlit solar diffuser (SD) at a stable radiance level, considering a slowly changing SD reflectance degradation. These measurements provide time-dependent gain adjustment factors, and the calibration assumes a linear response for each band and detector. Hence, an analysis of the dependence on different radiance levels is warranted. The MODIS design has no mechanism for varying radiance levels, except for an attenuator screen. However, it has been in static configuration for Terra since mid-2003. An external source of radiance attenuation can be utilized during solar eclipse events, while maintaining high stability and accuracy of solar calibration standards. Due to its long mission lifetime, Terra has seen several Sun-Moon near-conjunction events when it coincides with the orbit path where the SD is directly illuminated. As of August 2020, we have identified 7 viable partial solar eclipses in the Terra mission data. We will discuss several results of our study, including comparison of measured SD signal to predicted radiance reduction based on a solar disk radiance model; nominal and outlier behavior as a function of bands, detectors, and mirror-sides; and comparison with other data sets. Our main conclusion from this study is that there is no notable correlation of detector-dependent trend with radiance level for most RSB bands.

Terra↗

Nonlinear Detector Response of Aqua MODIS Land Imaging Bands

The detectors in Aqua MODIS reflective solar bands (RSB) are calibrated assuming a linear relationship between the observed top-of-atmosphere radiance and the instrument output response. Any non-linear behavior in the system response can contribute to errors in NASA’s Level 1B MODIS reflectance and radiance products, which are used in a wide variety of Earth science applications. While most RSB detectors continue to have very linear behavior even after more than 18 years of operation, we present evidence that the detectors in Aqua MODIS bands 1 (645 nm) and 2 (858 nm) have deviations from gain linearity that change over the mission by up to 3%. We show a clear divergence between gain measurements made with the on-board solar diffuser (SD) at two different radiance levels, achieved by collecting data both with and without an attenuation screen. Radiance trends from lunar calibrations and typical desert and ocean scenes are also compared. We present a simple method to characterize the response non-linearity using a quadratic function by combining the results of the two sets of SD calibrations. Applying this quadratic calibration algorithm to the desert and lunar data results in improved agreement in their long-term radiance trends. A clear understanding of the magnitude of the gain non-linearity could be useful to help improve the quality of numerous MODIS science products, including the land imaging applications that rely heavily on these bands.

MODIS↗

SNPP VIIRS RSB on-orbit radiometric calibration algorithms Version 2.0 and the performances. Part I: The algorithms

The first VIIRS instrument is aboard the Suomi National Polar-orbiting Partnership satellite. The instrument has 14 reflective solar bands (RSBs) to passively collect photons reflected from the Earth surface in the design wavelengths from 412 to 2250 nm. The instrument uses a solar diffuser (SD) to radiometrically calibrate its RSBs. When lit by the Sun through an attenuation screen (the SD screen), the SD diffusely reflects off the incident sunlight to act as a radiance source for the calibration. An onboard solar diffuser stability monitor (SDSM) yields the on-orbit change of the SD bidirectional reflectance distribution function (BRDF) by comparing the signal strength from the SD with that from the Sun attenuated by another attenuation screen (the SDSM screen). Complications arise due to the discovery that the on-orbit change of the BRDF is angle dependent. Additionally, the SDSM does not cover the wavelengths for the short-wave infrared bands in the RSBs. Furthermore, satellite yaw maneuvers were performed in the early mission to yield data for refining the prelaunch SDSM screen relative effective transmittance and the relative product of the SD screen transmittance and the BRDF at the mission start. But the yaw maneuver data are coarse in the solar azimuth angles and thus are unable to yield accurate values between the measurement angles. Over the years of performing on-orbit radiometric calibration through the SD for the VIIRSRSBs, we have developed several highly effective calibration algorithms to address the issues mentioned above. This paper reviews these algorithms.

on-orbit cailbration↗

SNPP VIIRS RSB on-orbit radiometric calibration algorithms Version 2.0 and the performances. Part II: The performances

In Part I (Lei et. al, submitted to J. of Appl. Rem. Sens.),we gave detailed reviews of the algorithms Version 2.0 used for the on-orbit radiometric calibration of the reflective solar bands (RSBs) of the first Visible Infrared Imaging Radiometer Suite instrument. These algorithms improve the accuracy of the measured on-orbit change factor of the solar diffuser bidirectional reflectance distribution function, the H-factor, and reveal that the H-factor is angle dependent. With the help of lunar observations and the improved H-factor, the algorithms give more accurate values for the RSB detector on-orbit F-factor changes (F-factor is a correction factor to the initially retrieved scene spectral radiance). In this paper we review the RSB radiometric calibration performances. We show the H-factor temporal trend, the estimated uncertainty of the retrieved H-factor, and the F-factor temporal trend. Additionally we show the detector signal-to-noise ratio (SNR), the estimated uncertainty of the top-of-the-atmosphere solar spectral reflectance, the reflectance temporal trend for the Libya 4 desert, and the differences in the reflectances among the SNPP and the NOAA-20 VIIRS, and the Aqua MODIS. Our results show that although the SNRs trend downwards, they exceed the requirements by large margins. The reflectances from the Libya 4 desert show that the SNPP VIIRS’ reflectance is higher than those of the Aqua MODIS and the NOAA-20 VIIRS.

on-orbit calibration↗

SNPP VIIRS RSB on-orbit radiometric calibration algorithms Version 2.0 and the performances. Part II: The performances

In Part I (Lei et. al, submitted to J. of Appl. Rem. Sens.),we gave detailed reviews of the algorithms Version 2.0 used for the on-orbit radiometric calibration of the reflective solar bands (RSBs) of the first Visible Infrared Imaging Radiometer Suite instrument. These algorithms improve the accuracy of the measured on-orbit change factor of the solar diffuser bidirectional reflectance distribution function, the H-factor, and reveal that the H-factor is angle dependent. With the help of lunar observations and the improved H-factor, the algorithms give more accurate values for the RSB detector on-orbit F-factor changes (F-factor is a correction factor to the initially retrieved scene spectral radiance). In this paper we review the RSB radiometric calibration performances. We show the H-factor temporal trend, the estimated uncertainty of the retrieved H-factor, and the F-factor temporal trend. Additionally we show the detector signal-to-noise ratio (SNR), the estimated uncertainty of the top-of-the-atmosphere solar spectral reflectance, the reflectance temporal trend for the Libya 4 desert, and the differences in the reflectances among the SNPP and the NOAA-20 VIIRS, and the Aqua MODIS. Our results show that although the SNRs trend downwards, they exceed the requirements by large margins. The reflectances from the Libya 4 desert show that the SNPP VIIRS’ reflectance is higher than those of the Aqua MODIS and the NOAA-20 VIIRS

Ning Lei↗

The MODIS RSB calibration and look-up-table delivery process for Collection 6 and 6.1

The Moderate Resolution Imaging Spectroradiometer (MODIS) instruments on-board the Aqua and Terra space-craft have provided valuable science data for the last 18 and 20 years, respectively. Each instrument is equipped with 36 spectral bands, 20 of which are reflective solar bands (RSBs). These bands cover a wavelength range of 0.4 – 2.2μm and are calibrated on-orbit using several on-board calibrators (OBCs), such as a solar diffuser (SD)and a solar diffuser stability monitor (SDSM), along with regularly-scheduled lunar observations through the space view (SV) port. The gain (1/m1) and response-verses-scan angle (RVS) are updated on a near-monthly basis and act as the primary look-up-tables (LUTs) for the RSB calibration. A set of separate uncertainty LUTs for each of the RSBs are also delivered regularly and incorporated into the Level 1B (L1B) product to generate a pixel-level Uncertainty Index (UI). In addition to the gain, RVS and uncertainty, there are several other LUTs associated with the reflective bands that are either updated less frequently or remain static. The accuracy of both the forward-predicted and historical RSB LUTs, which are derived by the MODIS Characterization Sup-port Team (MCST), is important in maintaining the quality and accuracy of the L1B and science products.To ensure a timely and accurate LUT update, MCST has established a comprehensive set of procedures. This paper provides an overview of the calibration process, along with the current LUT delivery process for the RSB sin Collection 6 (C6) and Collection 6.1 (C6.1). Improvements to be implemented in future collections are also discussed.

MODIS↗

Effects of Out-of-Band and Time-Varying Relative Spectral Response on the Calibration of MODIS Reflective Solar Bands

Calibration of the on-orbit gain changes of the narrow bandwidth reflective solar bands (RSB) of Terra and Aqua MODIS is usually based on the band center wavelength. The relative spectral response (RSR) of each band is assumed to be constant on orbit and the time dependence of an overall gain factor is calculated. Any on-orbit changes to the RSR of the MODIS bands will introduce some error into the calibration and may also have an impact on the Earth scene radiance retrieval. We consider two different ways to track how the RSR of the MODIS RSB may be changing on orbit, and the effects that these changes will have on the calibration. First, we study the broadband degradation of the MODIS scan mirror and how it may be changing the effective out-of-band response of the RSB. Second, we examine in-band RSR measurements from the spectro-radiometric calibration assembly (SRCA) carried on-board both MODIS instruments. We find that RSR changes have a relatively small effect on the radiance calibrated using the on-board solar diffuser, generally less than 0.5% for all RSB at any time in the missions, though the effect may be slightly larger for some scan angles. The impact of RSR changes on the Earth scene radiance retrieval is highly dependent on the spectral properties of the scene and could be significantly larger. The bands showing the largest impacts are Terra bands 1, 4, 8, 9, 17, and 19 and Aqua bands 8 and 9.

MODIS↗

On-Orbit Tracking of Sub-Sample Gain Differences in SNPP and NOAA-20 VIIRS Imagery Bands

The VIIRS instruments on board the SNPP and NOAA-20 (N20) satellites have 14 reflective solar bands covering a spectral range from 412 nm to 2250 nm. Three of these are imaging bands (I bands) with a nadir spatial resolution of 375 m and 11 are moderate resolution bands (M bands) with a resolution of 750 m. The higher resolution in the I bands is achieved by a combination of more detectors, with the I bands having twice as many detectors of half the size for every M band detector, and a higher data rate, with the I bands having two sub-samples for every sample of M band data. To ensure calibration accuracy, any systematic difference in the response of the two sub-samples needs to be monitored and corrected in the calibrated products. In this paper, we use the solar diffuser calibrations to monitor the gain differences between the two sub-samples of the I bands both as a function of time and signal level. We find gain differences of about 0.1% for I1, 0.3% for I2, and <0.1% for I3 that are mostly constant over the range of signal values available in the SD calibration. These values are mostly consistent throughout the mission for both instruments. The results are remarkably similar for the two VIIRS instruments, including a slightly out-of-family behavior seen in a few detectors. We discuss possible causes for the difference and the impact on the aggregated Earth view images.

On-orbit↗

MODIS Reflective Solar Bands On-Orbit Calibration and Performance

The design of the MODIS instrument was driven by the scientific community's desire to have near-daily global coverage at moderate resolution (1 km) with a comprehensive spectral coverage from visible to long-wave infrared wavelengths. Since their launches in 1999 and 2002, respectively, the Terra and Aqua MODIS instruments have made continuous global observations and generated numerous data products to help users worldwide with their studies of the Earth's system and its short- and long-term changes. The 20 reflective solar bands (RSB) with wavelengths from 0.41 to 2.2 m collect data at three nadir spatial resolutions: 250 m, 500 m, and 1 km. The solar diffuser (SD) coupled with the solar diffuser stability monitor (SDSM) provide a reflectance-based calibration on-orbit. In addition, lunar observations and response trends from pseudo-invariant desert sites are used to characterize the response versus scan- angle changes on-orbit. This paper provides a brief overview of MODIS RSB calibration algorithms, as implemented in the latest Level 1B version 6.1, operational activities, on-orbit performance, remaining challenges and potential improvements. Results from the SD and SDSM measurements show a wavelength and mirror side dependent degradation in RSB responses, with the largest degradation at the shortest wavelengths, particularly for Terra MODIS. Aqua MODIS has experienced far less degradation of its optics and on-board calibrators compared to Terra MODIS, resulting in an overall better performance. With the exception of Aqua band 6, there have been no new noisy or inoperable detectors in the RSB of either instrument during post-launch operations. As the instruments age and continue to endure the space environment, the detectors and optical systems degrade. The challenges associated with incorporating these on-orbit changes to ensure a production of high-quality calibrated L1B data products are also discussed in this paper.

solar diffuser stability monitor↗

Twenty Years of Terra MODIS Spatial Performance Using the Spectro-Radiometric Calibration Assembly

The Moderate Resolution Imaging Spectroradiometer (MODIS) instrument on-board the NASA’s Earth Observing System Terra satellite has continued successful Earth-sensing operations for over 20 years. To aid in its mission in providing calibrated science data to the worldwide user community, the MODIS instrument is equipped with several on-board calibrators designed to measure changes in the instrument response over time. One such calibrator is the Spectro-Radiometric Calibration Assembly (SRCA), which can provide a source signal for radiometric, spectral, or spatial characterization. When commanded into its spatial calibration mode, the SRCA is able to produce light across the MODIS band spectral range (0.412μm to 14.2μm) at a variety of signal levels thanks to several internal halogen lamps, an IR glow bar, and a neutral density filter. This signal, used in combination with commanded sub-sample measurements of the MODIS detectors, provides a basis for determining changes in the spatial performance of the MODIS spectral bands. This work summarizes the spatial calibration process using the SRCA and presents 20 years of Terra MODIS spatial performance characterized through co-registration between MODIS bands, detectors, and focal plane assemblies. Results from pre-launch testing using the Integration and Alignment Collimator and the SRCA are incorporated in the history of the Terra MODIS mission-long spatial performance. We also note modifications to the spatial characterization methodology brought on by changes to the SRCA’s operational configuration and changes to the MODIS spectral band performance, particularly after the recovery from the safe-mode event in February 2016. Results are compared against the MODIS design specifications.

MODIS↗