Search NASA⌕ Search

Engineering topics

Keyser, Matthew

Publications and source records attributed to Keyser, Matthew.

28 records · Page 2

Enabling fast charging – Introduction and overview

Argonne National Laboratory (Argonne), Idaho National Laboratory (INL), and the National Renewable Energy Laboratory (NREL), with guidance from VTO, initiated this study to understand the technical, cost, infrastructure, and implementation barriers associated with high rate charging up to 350 kW.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Enabling Fast Charging: A Technology Gap Assessment

The transportation sector accounts for the largest percentage of energy use in the United States. Decreasing energy consumption across this sector, especially in commercial light duty transportation, is essential for the U.S. to gain energy independence. Recently, powertrain electrification with plug-in electric vehicles (PEVs) have gained traction as an alternative due to their inherent efficiency advantages compared to the traditional internal combustion engine vehicle (ICEV). Accounting for 500,000 vehicle on the road today, these PEVs will reduce oil imported into the U.S. by five billion gallons and save two billion dollars in fuel costs to consumers over their useful life. Though there are many different classes of PEV, the intent of this study is to focus on non-hybrid powertrains, or battery electric vehicles (BEVs). Despite rapid drops in cost within the BEV powertrain of over 4x in the last 10 years, the PEV market still only accounts for approximately 1% of new light duty vehicle sales annually. Though BEV powertrain costs are not quite at parity with the ICEV, another gap to wider adoption of BEVs that have been identified is the ability to refuel quickly, or to fast charge. Though the majority of recharging BEVs is done at home, having access to fast charge stations has a big impact on BEV utility from a consumer perspective. To address the fast charge barrier, charging at 350 kW, or extreme fast charging (XFC), has been proposed and will serve as the basis for discussion in this report. Studies have shown that in areas where drivers have access to 50 kW or 120 kW fast charge stations, annual electric vehicle miles traveled (eVMT) increased by over 25%, even in cases where fast charging was used for 1-5% of total charging events [1, 2]. Having access to these fast charge stations can help alleviate the “range anxiety” that is cited as a common reason for consumers to hesitate to buy a BEV. Though, to be truly competitive to the ICEV refueling experience, even higher power stations are necessary. These extreme fast charge stations (XFC) should be able to recharge a BEV in less than 10 minutes and provide approximately 175 additional miles of driving. However, this introduces a host of new challenges that need to be addressed. As a result, it is expected that packs designed to meet XFC will be significantly more expensive initially than BEVs optimized for range that can reach 140kW with current technology. From the battery cell to the power grid to which these 350 kW chargers are connected, this study will discuss the issues that need to be addressed at each level in order to implement a 350 kW charging network. Although this report is U.S.-focused, the findings should be applicable to other countries with mature automotive infrastructures.

25 ENERGY STORAGE↗

On Demand Internal Short Circuit Device Enables Verification of Safer, Higher Performing Battery Designs

The Internal Short Circuit (ISC) device enables critical battery safety verification. With the aluminum interstitial heat sink between the cells, normal trigger cells cannot be driven into thermal runaway without excessive temperature bias of adjacent cells. With an implantable, on-demand ISC device, thermal runaway tests show that the conductive heat sinks protected adjacent cells from propagation. High heat dissipation and structural support of Al heat sinks show high promise for safer, higher performing batteries.

25 ENERGY STORAGE↗

Characterising thermal runaway within lithium-ion cells by inducing and monitoring internal short circuits

Lithium-ion batteries are being used in increasingly demanding applications where safety and reliability are of utmost importance. Thermal runaway presents the greatest safety hazard, and needs to be fully understood in order to progress towards safer cell and battery designs. Here, we demonstrate the application of an internal short circuiting device for controlled, on-demand, initiation of thermal runaway. Through its use, the location and timing of thermal runaway initiation is pre-determined, allowing analysis of the nucleation and propagation of failure within 18 650 cells through the use of high-speed X-ray imaging at 2000 frames per second. Furthermore, the cause of unfavourable occurrences such as sidewall rupture, cell bursting, and cell-to-cell propagation within modules is elucidated, and steps towards improved safety of 18 650 cells and batteries are discussed.

30 DIRECT ENERGY CONVERSION↗

Research Tool to Evaluate the Safety Response of Lithium Batteries to an Internal Short Circuit

Li-ion cells provide the highest specific energy and energy density rechargeable battery with the longest life. Many safety incidents that take place in the field originate due to an internal short that was not detectable or predictable at the point of manufacture. NREL's internal short circuit (ISC) device is capable of simulating shorts and produces consistent and reproducible results. The cell behaves normally until the ISC device is activated wherein a latent defect (i.e., built into the cell during manufacturing) gradually moves into position to create an internal short while the battery is in use, providing relevant data to verify abuse models. The ISC device is an effective tool for studying the safety features of parts of Li-ion batteries.

25 ENERGY STORAGE↗

Battery Thermal Characterization

This poster shows the progress in battery thermal characterization over the previous year. NREL collaborated with U.S. DRIVE and USABC battery developers to obtain thermal properties of their batteries, obtained heat capacity and heat generation of cells under various power profiles, obtained thermal images of the cells under various drive cycles, and used the measured results to validate thermal models. Thermal properties are used for the thermal analysis and design of improved battery thermal management systems to support achieve life and performance targets.

25 ENERGY STORAGE↗

NREL/NASA Internal Short-Circuit Instigator in Lithium Ion Cells

Lithium-ion cells provide the highest specific energy (>280 Wh/kg) and energy density (>600 Wh/L) rechargeable battery building block to date with the longest life. Electrode/electrolyte thermal instability and flammability of the electrolyte of Li-ion cells make them prone to catastrophic thermal runaway under some rare internal short circuit conditions. Despite extensive QC/QA, standardized industry safety testing, and over 18 years of manufacturing experience, major recalls have taken place and incidents still occur. Many safety incidents that take place in the field originate due to an internal short that was not detectable or predictable at the point of manufacture. The Internal Short-Circuit Instigator can be used to study types of separators, non-flammable electrolytes, electrolyte additives, fusible tabs, propagation studies, and gas generation within a cell.

30 DIRECT ENERGY CONVERSION↗

Passive safety device and internal short tested method for energy storage cells and systems

A passive safety device for an energy storage cell for positioning between two electrically conductive layers of the energy storage cell. The safety device also comprising a separator and a non-conductive layer. A first electrically conductive material is provided on the non-conductive layer. A first opening is formed through the separator between the first electrically conductive material and one of the electrically conductive layers of the energy storage device. A second electrically conductive material is provided adjacent the first electrically conductive material on the non-conductive layer, wherein a space is formed on the non-conductive layer between the first and second electrically conductive materials. A second opening is formed through the non-conductive layer between the second electrically conductive material and another of the electrically conductive layers of the energy storage device. The first and second electrically conductive materials combine and exit at least partially through the first and second openings to connect the two electrically conductive layers of the energy storage device at a predetermined temperature.

25 ENERGY STORAGE↗

On-Demand Cell Internal Short Circuit Device

A device implantable in Li-ion cells that can generate a hard internal short circuit on-demand by exposing the cell to 60C has been demonstrated to be valuable for expanding our understanding of cell responses. The device provides a negligible impact to cell performance and enables the instigation of the 4 general categories of cell internal shorts to determine relative severity and cell design susceptibility. Tests with a 18650 cell design indicates that the anode active material short to the aluminum cathode current collector tends to be more catastrophic than the 3 other types of internal shorts. Advanced safety features (such as shutdown separators) to prevent or mitigate the severity of cell internal shorts can be verified with this device. The hard short success rate achieved to date in 18650 cells is about 80%, which is sufficient for using these cells in battery assemblies for field-failure-relevant, cell-cell thermal runaway propagation verification tests

Darcy, Eric↗