A White Paper on Design and Fabrication of SRF Deflecting Cavities for Elletra-2
Synchrotron Trieste (ST) operates an X-ray light source Elettra and plans to upgrade it to a low-emittance high-brightness X-ray source Elettra-2.0 based on a multi-bend achromat lattice. There is also a significant interest among Elettra users to pursue time-resolved studies of matter choosing the appropriate X-ray pulse duration in the range from 20 picoseconds to a few picoseconds FWHM. Recently, X. Huang (SLAC) and A. Zholents (ANL) performed a study sponsored by ST and proposed modifications to the Elettra-2.0 design that will allow production of picosecond x-ray pulses on many beamlines. They showed that two radio frequency deflecting cavities with slightly different frequencies can be installed in the ring’s sector 8 and produce time-dependent orbit deflection to a few dedicated electron bunches without affecting other regular bunches. These special bunches produce X-ray pulses in which transverse position or angle, or both, are correlated with time. The short X-ray pulse is then obtained by using a narrow slit positioned downstream in the beamline. Many technical details of the proposed modification to Elettra-2.0 are discussed in the supplemental report. We present here the design of a multicell superconducting deflecting cavity for the purpose of the ST Short Pulse X-ray (SPX) project.