Search NASA⌕ Search

Engineering topics

Kilcrease, David P.

Publications and source records attributed to Kilcrease, David P..

Density-matrix correlations in the relaxation theory of electron broadening

Spectral lines of radiating atoms are broadened by perturbations due to the surrounding plasma environment. In line-broadening calculations, the statistical average of the perturbation is weighted by the density matrix, which, in thermal equilibrium, contains correlations between the radiator and plasma. These correlations, however, have been neglected by all line-broadening theories except for the kinetic theory. The relaxation theory of line broadening is a mathematically exact derivation containing only one physical approximation: neglect of density- matrix correlations. We revisit this derivation and improve it by including the correlations. The line-broadening operator derived with the updated relaxation theory differs from that derived from the kinetic theory, though both derivations are considered to be exact. The kinetic theory derivation predicts that density-matrix correlations result a strong static shift of spectral lines. Our derivation, on the other hand, predicts that the correlations are a frequency-dependent effect that affects the line wings, and there is no shift of the line due to correlations. In addition, we predict that changes in the line shape due to correlations are only noticeable at extremely high densities. To distinguish the more appropriate model, we compare the shifts calculated with the relaxation and kinetic theory with data. The comparison shows support for the relaxation theory and casts into doubt the accuracy of the derivation of the kinetic theory of line broadening.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analysis of geological materials containing uranium using laser-induced breakdown spectroscopy

Laser induced breakdown spectroscopy (LIBS) is a rapid atomic emission spectroscopy technique that can be configured for a variety of applications including space, forensics, and industry. LIBS can also be configured for stand-off distances or in-situ, under vacuum, high pressure, atmospheric or different gas environments, and with different resolving-power spectrometers. In this paper, the detection of uranium in a complex geological matrix under different measurement schemes is explored. Although many investigations have been completed in an attempt to detect and quantify uranium in different matrices at in-situ and standoff distances, this work detects and quantifies uranium in a complex matrix under Martian and ambient air conditions. Investigation of uranium detection using a low resolving-power LIBS system at stand-off distances (1.6 m) is also reported. The results are compared to an in-situ LIBS system with medium resolving power and under ambient air conditions. Uranium has many thousands of emission lines in the 200–800 nm spectral region. In the presence of other matrix elements and at lower concentrations, the limit of detection of uranium is significantly reduced. The two measurement methods (low and high resolving-power spectrometers) are compared for limit of detection (LOD). Of the twenty-one potential diagnostic uranium emission lines, seven (409, 424, 434, 435, 436, 591, and 682 nm) have been used to determine the LOD for pitchblende in a dunite matrix using the ChemCam test bed LIBS system. The LOD values determined for uranium transitions in air are 409.013 nm (24,700 ppm), 424.167 nm (23,780 ppm), 434.169 nm (24,390 ppm), 435.574 nm (35,880 ppm), 436.205 nm (19,340 ppm), 591.539 nm (47,310 ppm), and 682.692 nm (18,580 ppm). The corresponding LOD values determined for uranium transitions in 7 Torr CO2 are 424.167 nm (25,760 ppm), 434.169 nm (40,800 ppm), 436.205 nm (32,050 ppm), 591.539 nm (15,340 ppm), and 682.692 nm (29,080 ppm). The LOD values determine for uranium emission lines using the medium resolving power (10,000 λ/Δλ) LIBS system for the dunite matrix in air are 409.013 nm (6120 ppm), 424.167 nm (5356 ppm), 434.169 nm (5693 ppm), 435.574 nm (6329 ppm), 436.205 nm (2142 ppm), and 682.692 nm (10,741 ppm). The corresponding LOD values determined for uranium transitions in a SiO2 matrix are 409.013 nm (272 ppm), 424.167 nm (268 ppm), 434.169 nm (402 ppm), 435.574 nm (1067 ppm), 436.205 nm (482 ppm), and 682.692 nm (720 ppm). The impact of spectral resolution, atmospheric conditions, matrix elements, and measurement distances on LOD is discussed. The measurements will assist one in selecting the proper system components based upon the application and the required analytical performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗