Measurement of branching fraction and search for C P violation in B → ϕ ϕ K
Not Available
Engineering topics
Publications and source records attributed to Kim, C.
Not Available
To avoid access to PFS, dedicated BB allocation is preferred despite of severe BB underutilization. Recently, new all-flash HPC storage systems with integrated BB and PFS are proposed, which speed up access to PFS. For this reason, we adopt BB over-subscription allocation method by allowing HPC applications to use BB only for I/O phase for improving BB utilization. Unfortunately, BB over-subscription aggravates I/O interference and demotion overhead from BB to PFS, resulting in degraded performance. To minimize the performance degradation, we develop an I/O scheduler to prevent I/O congestion and a new transparent data management system based on checkpoint/restart characteristics of HPC applications. With the proposed approach, not only the BB utilization can be improved, but also high performance of applications is achieved. In our experiments, we find that BB utilization is improved at least 2.2x, and more stable and higher checkpoint performance is guaranteed compared to other approaches. Besides, we achieve up to 96.4% hit ratio of restart requests on BB and up to 3.1x higher restart performance than others.
Explore the source record for details and available documents.
Purpose: To reduce radiation dose to the patients, tube current modulation (TCM) method has been actively used in diagnostic CT systems. However, TCM method has not yet been applied to a kV-CBCT system on a LINAC machine. The purpose of this study is to investigate whether the use of TCM method is desirable in kV-CBCT system for IGRT. We have developed an attenuation-based tube current modulation (a-TCM) method using the prior knowledge of treatment CT image of a patient. Methods: Patients go through a diagnostic CT scan for RT planning; therefore, using this prior information of CT images, one can estimate the total attenuation of an x-ray through the patient body in a CBCT setting for radiation therapy. We performed a numerical study incorporating major factors into account such as polychromatic x-ray, scatter, noise, and bow-tie filter to demonstrate that a-TCM method can produce equivalent quality of images at reduced imaging radiation doses. Using the CT projector program, 680 projection images of the pediatric XCAT phantom were obtained both in conventional scanning condition, i.e., without modulating the tube current, and in the proposed a-TCM scanning condition. FDK reconstruction algorithm was used for image reconstruction, and the organ dose due to imaging radiation has been calculated in both cases and compared using GATE/Geant4 simulation toolkit. Results: Reconstructed CT images in the a-TCM method showed similar SSIM values and noise properties to the reference images acquired by the conventional CBCT. In addition, reduction of organ doses ranged from 12% to 27%. Conclusion: We have successfully demonstrated the feasibility and dosimetric merit of the a-TCM method for kV-CBCT, and envision that it can be a useful option of CBCT scanning that provides patient dose reduction without degrading image quality.
Purpose: Focal radiosurgery is a common treatment modality for trigeminal neuralgia (TN), a neuropathic facial pain condition. Assessment of treatment effectiveness is primarily clinical, given the paucity of investigational tools to assess trigeminal nerve changes. The efficiency of radiosurgery is related to its highly precise targeting. We assessed clinically the targeting accuracy of radiosurgery with Gamma knife. We hypothesized that trigeminal tractography provides more information than 2D-MR imaging, allowing detection of unique, focal changes in the target area after radiosurgery. Methods: Sixteen TN patients (2 females, 4 males, average age 65.3 years) treated with Gamma Knife radiosurgery, 40 Gy/50% isodose line underwent 1.5Tesla MR trigeminal nerve. Target accuracy was assessed from deviation of the coordinates of the target compared with the center of enhancement on post MRI. Radiation dose delivered at the borders of contrast enhancement was evaluated. Results: The median deviation of the coordinates between the intended target and the center of contrast enhancement was within 1mm. The radiation doses fitting within the borders of the contrast enhancement the target ranged from 37.5 to 40 Gy. Trigeminal tractography accurately detected the radiosurgical target. Radiosurgery resulted in 47% drop in FA values at the target with no significant change in FA outside the target, suggesting that radiosurgery primarily affects myelin. Tractography was more sensitive, since FA changes were detected regardless of trigeminal nerve enhancement. Conclusion: The median deviation found in clinical assessment of gamma knife treatment for TN Is low and compatible with its high rate of efficiency. DTI parameters accurately detect the effects of focal radiosurgery on the trigeminal nerve, serving as an in vivo imaging tool to study TN. This study is a proof of principle for further assessment of DTI parameters to understand the pathophysiology of TN and treatment effects.
Purpose: A prototype actives scanning beam delivery system was designed, manufactured and installed as a part of the Korea Heavy Ion Medical Accelerator Project. The prototype system includes the most components for steering, modulating, detecting incident beam to patient. The system was installed in MC-50 cyclotron beam line and tested to extract the normal operation conditions. Methods: The commissioning process was completed by using 45 MeV of proton beam. To measure the beam position accuracy along the scanning magnet power supply current, 25 different spots were scanning and measured. The scanning results on GaF film were compared with the irradiation plan. Also, the beam size variation and the intensity reduction using range shifter were measured and analyzed. The results will be used for creating a conversion factors for asymmetric behavior of scanning magnets and a dose compensation factor for longitudinal direction. Results: The results show asymmetry operations on both scanning × and y magnet. In case of scanning magnet × operation, the current to position conversion factors were measured 1.69 mm/A for positive direction and 1.74 mm/A for negative direction. The scanning magnet y operation shows 1.38mm/A and 1.48 mm/A for both directions. The size of incoming beam which was 18 mm as sigma becomes larger up to 55 mm as sigma while using 10 mm of the range shifter plate. As the beam size becomes large, the maximum intensity of the was decreased. In case of using 10 mm of range shifter, the maximum intensity was only 52% compared with no range shifter insertion. Conclusion: For the appropriate operation of the prototype active scanning system, the commissioning process were performed to measure the beam characteristics variation. The obtained results would be applied on the irradiation planning software for more precise dose delivery using the active scanning system.
Purpose: Focal radiosurgery is a common treatment modality for trigeminal neuralgia (TN), a neuropathic facial pain condition. Assessment of treatment effectiveness is primarily clinical, given the paucity of investigational tools to assess trigeminal nerve changes. The efficiency of radiosurgery is related to its highly precise targeting. We assessed clinically the targeting accuracy of radiosurgery with Gamma knife. We hypothesized that trigeminal tractography provides more information than 2D-MR imaging, allowing detection of unique, focal changes in the target area after radiosurgery. Methods: Sixteen TN patients (2 females, 4 male, average age 65.3 years) treated with Gamma Knife radiosurgery, 40 Gy/50% isodose line underwent 1.5Tesla MR trigeminal nerve . Target accuracy was assessed from deviation of the coordinates of the target compared with the center of enhancement on post MRI. Radiation dose delivered at the borders of contrast enhancement was evaluated Results: The median deviation of the coordinates between the intended target and the center of contrast enhancement was within 1mm. The radiation doses fitting within the borders of the contrast enhancement the target ranged from 37.5 to 40 Gy. Trigeminal tractography accurately detected the radiosurgical target. Radiosurgery resulted in 47% drop in FA values at the target with no significant change in FA outside the target, suggesting that radiosurgery primarily affects myelin. Tractography was more sensitive, since FA changes were detected regardless of trigeminal nerve enhancement Conclusion: The median deviation found in clinical assessment of gamma knife treatment for TN Is low and compatible with its high rate of efficiency. DTI parameters accurately detect the effects of focal radiosurgery on the trigeminal nerve, serving as an in vivo imaging tool to study TN. This study is a proof of principle for further assessment of DTI parameters to understand the pathophysiology of TN and treatment effects.
Purpose: To verify the design criteria on heavy ion beam irradiation, developing a proto type active scanning system was purposed. The active scanning system consists of scanning magnet, power supplies, beam monitors, energy modulation system, and irradiation control system. Methods: Each components of the active scanning system was designed for carbon beam first. For the fast ramping a laminated yoke was purposed. To measure incoming dose and profile, a plate and strip type of ion chambers were designed. Also, ridge filter and range shifter was manufactured. And, the scanning system was modified to adopt 45 MeV of proton beam because of the absence of carbon ion beam in Korea. The system was installed in a beam line at MC-50, KIRAMS. Also, the irradiation control system and planning software was provided. Results: The scanning experiment was performed by drawing KHIMA logo on GaF film. The logo was scanned by 237 scanning points through time normalized intensity modulation. Also, a grid points scanning was performed to measure the scanning resolution and intensity resolution. Conclusion: A prototype active scanning system was successfully designed and manufactured. Also, an initial experiment to print out a drawing on GaF film through the scanning system was completed. More experiments would be required to specify the system performance.
Explore the source record for details and available documents.
Abstract not provided
The growth and stability of the Pb8 x 8 wetting layer on Si(111)7 x 7, which provides a foundation for growing quantum-size-effect nanocrystals, was investigated by in situ x-ray scattering. Our experimental results reveal that the wetting-layer structure evolves temporally over a remarkably broad range of temperatures and that there are two distinct temperature regimes of nonequilibrium behavior. When grown at lower temperature (below 170 C), it was discovered that the wetting-layer structure changes with time, indicating that its disordered structure is not static; annealing in this regime improves the order of the wetting layer. Growth at higher temperature (170 C < T < 250 C), however, leads to a time-dependent degradation of the 8 x 8 structure due to the deterioration of the underlying Si(111)7 x 7. Thermal measurements determined an activation energy of 0.4 eV in the low-temperature regime, whereas in the high-temperature regime, a two-step process is observed, which has activation energies of approximately 1.3 and 1.9 eV. The results provide important considerations for understanding the anomalous kinetic behavior of quantum-size-effect Pb nanocrystals on Si(111)7 x 7, which is facilitated by the wetting layer.
We have carried out diffuse X-ray scattering measurements of the growth of Pb nanocrystalline islands on Si(1 1 1). Analysis of our data shows that islands growing on an initially rough wetting layer transforms the portion of the wetting layer below them into ordered fcc sites. Therefore, the islands grow directly on top of the Si surface with a disordered wetting layer occupying the region between the islands and, consequently, the island height responsible for the quantum well depth is one layer thicker than reported by LEED and STM. These islands have an extremely good vertical order until the islands coalesce into a closed film. At that point the disorder of the film increases consistent with misfit strain relaxation.
With 4-cyanobiphenyl-4-yl benzoate nematogens chemically bonded to a benzene core via enantiomeric 2-methylpropyl spacers, a new series of cholesteric glassy liquid crystals has been synthesized for an investigation of structure-property relationships. Glass-forming ability, phase-transition temperatures, and stability against crystallization are affected by both the number and the position of substituent groups on the benzene ring with 1,3,5-trisubstituted system possessing the most favorable set of properties, Tg at 73 °C and Tc at 295 °C. With (S)-3-bromo-2-methylpropanol as the chiral precursor, left-handed helical stacking was observed for all the cholesteric GLCs reported herein. Films of the 1,3,5-trisubstituted and meta-disubstituted systems show a selective reflection wavelength, λR, at 413 and 422 nm, respectively, whereas that of the ortho-isomer exhibits a λR at 860 nm. Replacing one of the hybrid chiral-nematic mesogen in the 1,3,5-trisubstituted system by a nematogen loosens the helical pitch to yield a λR at 630 nm, still shorter than that of the ortho-isomer despite the dilution by a nematogen. This observation suggests the importance of regioisomerism to helical twisting. The difference in λR was interpreted in terms of molecular packing involving chiral spacers through computational chemistry. The susceptibility of cholesteric GLCs to photoalignment was tested using the ortho-isomer. The degree of photoalignment improves with an increasing rotational mobility of pendant coumarin monomers to an extent comparable to mechanical alignment on conventional rubbed polyimide films.
Recently, angle-resolved photoemission spectroscopy (ARPES) has been used to highlight an anomalously large band renormalization at high binding energies in cuprate superconductors: the high energy 'waterfall' or high energy anomaly (HEA). This paper demonstrates, using a combination of new ARPES measurements and quantum Monte Carlo simulations, that the HEA is not simply the byproduct of matrix element effects, but rather represents a cross-over from a quasi-particle band at low binding energies near the Fermi level to valence bands at higher binding energy, assumed to be of strong oxygen character, in both hole- and electron-doped cuprates. While photoemission matrix elements clearly play a role in changing the aesthetic appearance of the band dispersion, i.e. the 'waterfall'-like behavior, they provide an inadequate description for the physics that underlies the strong band renormalization giving rise to the HEA. Model calculations of the single-band Hubbard Hamiltonian showcase the role played by correlations in the formation of the HEA and uncover significant differences in the HEA energy scale for hole- and electron-doped cuprates. In addition, this approach properly captures the transfer of spectral weight accompanying both hole and electron doping in a correlated material and provides a unifying description of the HEA across both sides of the cuprate phase diagram.
Explore the source record for details and available documents.