Search NASA⌕ Search

Engineering topics

Kim, D

Publications and source records attributed to Kim, D.

At least 55 records · Page 3

SU-E-J-34: Clinical Evaluation of Targeting Accuracy and Tractogrphy Delineation of Radiosurgery

Purpose: Focal radiosurgery is a common treatment modality for trigeminal neuralgia (TN), a neuropathic facial pain condition. Assessment of treatment effectiveness is primarily clinical, given the paucity of investigational tools to assess trigeminal nerve changes. The efficiency of radiosurgery is related to its highly precise targeting. We assessed clinically the targeting accuracy of radiosurgery with Gamma knife. We hypothesized that trigeminal tractography provides more information than 2D-MR imaging, allowing detection of unique, focal changes in the target area after radiosurgery. Methods: Sixteen TN patients (2 females, 4 male, average age 65.3 years) treated with Gamma Knife radiosurgery, 40 Gy/50% isodose line underwent 1.5Tesla MR trigeminal nerve . Target accuracy was assessed from deviation of the coordinates of the target compared with the center of enhancement on post MRI. Radiation dose delivered at the borders of contrast enhancement was evaluated Results: The median deviation of the coordinates between the intended target and the center of contrast enhancement was within 1mm. The radiation doses fitting within the borders of the contrast enhancement the target ranged from 37.5 to 40 Gy. Trigeminal tractography accurately detected the radiosurgical target. Radiosurgery resulted in 47% drop in FA values at the target with no significant change in FA outside the target, suggesting that radiosurgery primarily affects myelin. Tractography was more sensitive, since FA changes were detected regardless of trigeminal nerve enhancement Conclusion: The median deviation found in clinical assessment of gamma knife treatment for TN Is low and compatible with its high rate of efficiency. DTI parameters accurately detect the effects of focal radiosurgery on the trigeminal nerve, serving as an in vivo imaging tool to study TN. This study is a proof of principle for further assessment of DTI parameters to understand the pathophysiology of TN and treatment effects.

60 APPLIED LIFE SCIENCES↗

SU-E-J-48: Development of An Abdominal Compression Device for Respiratory Correlated Radiation Therapy

Purpose: The aim of this study is to develop the abdominal compression device which could control pressure level according to the abdominal respiratory motion and evaluate its feasibility. Methods: In this study, we focused on developing the abdominal compression device which could control pressure level at any point of time so the developed device is possible to use a variety of purpose (gating technique or respiratory training system) while maintaining the merit of the existing commercial device. The compression device (air pad form) was designed to be able to compress the front and side of abdomen and the pressure level of the abdomen is controlled by air flow. Pressure level of abdomen (air flow) was determined using correlation data between external abdominal motion and respiratory volume signal measured by spirometer. In order to verify the feasibility of the device, it was necessary to confirm the correlation between the abdominal respiratory motion and respiratory volume signal and cooperation with respiratory training system also checked. Results: In the previous study, we could find that the correlation coefficient ratio between diaphragm and respiratory volume signal measured by spirometer was 0.95. In this study, we confirmed the correlation between the respiratory volume signal and the external abdominal motion measured by belt-transducer (correlation coefficient ratio was 0.92) and used the correlated respiratory volume data as an abdominal pressure level. It was possible to control the pressure level with negligible time delay and respiratory volume data based guiding waveforms could be properly inserted into the respiratory training system. Conclusion: Through this feasibility study, we confirmed the correlation between the respiratory volume signal and the external abdominal motion. Also initial assessment of the device and its compatibility with the respiratory training system were verified. Further study on application in respiratory gated therapy and respiratory training system will be investigated. This work was supported by Radiation Technology R and D program (No. 2013M2A2A7043498)and Basic Atomic Energy Research Institute (BAERI)(No. NRF-2009-0078390) through the National Research Foundation of Korea funded by the Ministry of Science, ICT and Future Planning.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SU-E-T-195: Gantry Angle Dependency of MLC Leaf Position Error

Purpose: The aim of this study was to investigate the gantry angle dependency of the multileaf collimator (MLC) leaf position error. Methods: An automatic MLC quality assurance system (AutoMLCQA) was developed to evaluate the gantry angle dependency of the MLC leaf position error using an electronic portal imaging device (EPID). To eliminate the EPID position error due to gantry rotation, we designed a reference maker (RM) that could be inserted into the wedge mount. After setting up the EPID, a reference image was taken of the RM using an open field. Next, an EPID-based picket-fence test (PFT) was performed without the RM. These procedures were repeated at every 45° intervals of the gantry angle. A total of eight reference images and PFT image sets were analyzed using in-house software. The average MLC leaf position error was calculated at five pickets (-10, -5, 0, 5, and 10 cm) in accordance with general PFT guidelines using in-house software. This test was carried out for four linear accelerators. Results: The average MLC leaf position errors were within the set criterion of <1 mm (actual errors ranged from -0.7 to 0.8 mm) for all gantry angles, but significant gantry angle dependency was observed in all machines. The error was smaller at a gantry angle of 0° but increased toward the positive direction with gantry angle increments in the clockwise direction. The error reached a maximum value at a gantry angle of 90° and then gradually decreased until 180°. In the counter-clockwise rotation of the gantry, the same pattern of error was observed but the error increased in the negative direction. Conclusion: The AutoMLCQA system was useful to evaluate the MLC leaf position error for various gantry angles without the EPID position error. The Gantry angle dependency should be considered during MLC leaf position error analysis.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-208: Incidence Cancer Risk From the Radiation Treatment for Acoustic Neuroma Patient

Purpose: The present study aimed to compare the incidence risk of a secondary cancer from therapeutic doses in patients receiving intensitymodulated radiotherapy (IMRT), volumetric modulated arc therapy (VMAT), and stereotactic radiosurgery (SRS). Methods: Four acoustic neuroma patients were treated with IMRT, VMAT, or SRS. Their incidnece excess relative risk (ERR), excess absolute risk (EAR), and lifetime attributable risk (LAR) were estimated using the corresponding therapeutic doses measured at various organs by radio-photoluminescence glass dosimeters (RPLGD) placed inside a humanoid phantom. Results: When a prescription dose was delivered in the planning target volume of the 4 patients, the average organ equivalent doses (OED) at the thyroid, lung, normal liver, colon, bladder, prostate (or ovary), and rectum were measured. The OED decreased as the distance from the primary beam increased. The thyroid received the highest OED compared to other organs. A LAR were estimated that more than 0.03% of AN patients would get radiation-induced cancer. Conclusion: The tyroid was highest radiation-induced cancer risk after radiation treatment for AN. We found that LAR can be increased by the transmitted dose from the primary beam. No modality-specific difference in radiation-induced cancer risk was observed in our study.

60 APPLIED LIFE SCIENCES↗

SU-E-T-239: Monte Carlo Modelling of SMC Proton Nozzles Using TOPAS

Purpose: To expedite and cross-check the commissioning of the proton therapy nozzles at Samsung Medical Center using TOPAS. Methods: We have two different types of nozzles at Samsung Medical Center (SMC), a multi-purpose nozzle and a pencil beam scanning dedicated nozzle. Both nozzles have been modelled in Monte Carlo simulation by using TOPAS based on the vendor-provided geometry. The multi-purpose nozzle is mainly composed of wobbling magnets, scatterers, ridge filters and multi-leaf collimators (MLC). Including patient specific apertures and compensators, all the parts of the nozzle have been implemented in TOPAS following the geometry information from the vendor.The dedicated scanning nozzle has a simpler structure than the multi-purpose nozzle with a vacuum pipe at the down stream of the nozzle.A simple water tank volume has been implemented to measure the dosimetric characteristics of proton beams from the nozzles. Results: We have simulated the two proton beam nozzles at SMC. Two different ridge filters have been tested for the spread-out Bragg peak (SOBP) generation of wobbling mode in the multi-purpose nozzle. The spot sizes and lateral penumbra in two nozzles have been simulated and analyzed using a double Gaussian model. Using parallel geometry, both the depth dose curve and dose profile have been measured simultaneously. Conclusion: The proton therapy nozzles at SMC have been successfully modelled in Monte Carlo simulation using TOPAS. We will perform a validation with measured base data and then use the MC simulation to interpolate/extrapolate the measured data. We believe it will expedite the commissioning process of the proton therapy nozzles at SMC.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-306: Study of the Reduction Technique for the Secondary Cancer Risk Due to Cone Beam CT in Image Guided Radiotherapy

Purpose: This study evaluated the effectiveness of a thin lead sheet based simple shielding method for imaging doses from cone beam computed tomography (CBCT) in image-guided radiotherapy (IGRT). Methods: The entire body, except for the region scanned by CBCT, was shielded by wrapping in a 2 mm lead sheet. Reduction of secondary doses from CBCT was measured using a radio-photoluminescence glass dosimeter (RPLGD) placed inside an anthropomorphic phantom and changes in secondary cancer risk due to the shielding effect were estimated using BEIR VII model. Results: Doses to out-of-field organs for head-and-neck, chest, and pelvis scans were decreased 15∼100 %, 23∼90 %, and 23∼98 %, respectively, and the average reductions in lifetime secondary cancer risk due to the 2 mm lead shielding were 1.61, 10.4, and 12.8 persons per 100,000, respectively. Conclusion: This study suggests that a simple thin lead sheet based shielding method results in a non-negligible reduction of secondary doses to out-of-field regions for CBCT.

60 APPLIED LIFE SCIENCES↗

SU-E-T-322: The Evaluation of the Gafchromic EBT3 Film in Low Dose 6 MV X-Ray Beams with Different Scanning Modes

Purpose: We have evaluated the response of the Gafchromic EBT3 film in low dose for 6 MV x-ray beams with two scanning modes, the reflection scanning mode and the transmission scanning mode. Methods: We irradiated the Gafcromic EBT3 film using a 60 degree enhanced dynamic wedge (EDW) with 6 MV x-ray beams from Clinac iX Linear accelerator (Varian Medical Systems, Palo Alto, CA). The irradiated Gafchromic EBT3 film was scanned with different scanning modes, the reflection scanning mode and the transmission scanning mode. The scanned Gafchromic EBT3 film was analyzed with MATLAB. Results: When 7.2 cGy was irradiated to the Gafchromic EBT3 film, the uncertainty was 0.54 cGy with reflection scanning mode and was 0.88 cGy with transmission scanning mode. When 24 cGy was irradiated to the Gafchromic EBT3 film, the uncertainty was similar to the case of 7.2 cGy irradiation showing 0.51 cGy of uncertainty with reflection scanning mode and 0.87 cGy of uncertainty with transmission scanning mode. The result suggests that the reflection mode should be used in Gafchromic EBT3 film for low irradiation. Conclusion: The result suggests that the reflection mode should be used in Gafchromic EBT3 film for low irradiation.

60 APPLIED LIFE SCIENCES↗

Enhanced high temperature performance of MgAl2O4-supported Pt-BaO lean NOx trap catalysts

The structural and chemical characteristics of Pt/BaO lean-NO{sub x} trap (LNT) catalysts supported on {gamma}-Al{sub 2}O{sub 3} and MgAl{sub 2}O{sub 4} are compared in this study. The Pt-BaO/MgAl{sub 2}O{sub 4} sample shows relatively low NO{sub x} uptake at temperatures below 300 C, and the temperature of maximum NO{sub x} uptake (T{sub max}) is shifted to 350 C in comparison to that of Pt-BaO/Al{sub 2}O{sub 3} (T{sub max} {approx}250 C). More importantly, the NO{sub x} uptake over the MgAl{sub 2}O{sub 4}-supported catalyst at 350 C is twice that of the alumina-based one. The shift toward the higher temperature NO{sub x} uptake is explained by the larger interfacial area between Pt and BaO, due to smaller Pt clusters as evidenced by TEM and Pt L3 EXAFS. In situ TR-XRD results demonstrate that the formation of a BaAl{sub 2}O{sub 4} phase in the BaO/MgAl{sub 2}O{sub 4} LNT catalyst occurs at a temperature about 100 C higher than on BaO/Al{sub 2}O{sub 3}, which may also represent a beneficial attribute of the BaO/MgAl{sub 2}O{sub 4} LNT with respect to catalyst stability.

36 MATERIALS SCIENCE↗

Effects of La2O3 on the Mixed Higher Alcohols Synthesis from Syngas over Co Catalysts: A Combined Theoretical and Experimental Study

The promoting role of lanthanum oxide (La{sub 2}O{sub 3}) in the catalytic synthesis of mixed higher (C{sub 2}-C{sub 6}) alcohols from syngas on Co-based catalysts was investigated using a combination of in situ and ex situ X-ray diffraction (XRD), photoelectron spectroscopy (XPS), catalyst reactivity performance studies, and ab initio molecular dynamics (AIMD) simulations. XRD measurements show that doping with La (0.5 wt %) onto activated carbon (AC) supported Co catalyst enhances the Co{sub 2}C phase formation, whereas the Co{sub 2}C phase formation is largely suppressed on alumina supported Co catalyst. A strong correlation of the selectivity toward alcohols with the ratio of Co{sub 2}C/Co particles present in the catalysts was observed. AIMD simulations suggest that on AC supports La exists as an oxide phase in the form of small clusters in the vicinity of Co particles. It was found that Co{sub 2}C formation is energetically favorable, especially for smaller Co particles because of the formation of surface carbide. Theoretical mechanistic studies indicate that oxygenated hydrocarbons can be formed on these catalysts by multiple routes involving the formation of CH{sub x}O and CH{sub x}CO species at the interface between the La{sub 2}O{sub 3} phase and Co/Co{sub 2}C. A detailed comparison with previous findings in the literature as well as discussion of the implications of these results upon the improvement of the selectivity of these catalysts toward higher alcohols is presented.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Printability and inspectability of Defects on the EUV Mask for sub32nm Half Pitch HVM Application

The availability of defect-free masks remains one of the key challenges for inserting extreme ultraviolet lithography (EUVL) into high volume manufacturing, yet little data is available for understanding native defects on real masks. In this paper, a full field EUV mask is fabricated to see the printability of various defects on the mask. Programmed pit defect shows that minimum printable size of pits could be 17 nm of SEVD from the AIT. However 23.1nm in SEVD is printable from the EUV ADT. Defect printability and identification of its source along from blank fabrication to mask fabrication were studied using various inspection tools. Capture ratio of smallest printable defects was improved to 80% using optimized stack of metrical on wafer and state-of-art wafer inspection tool. Requirement of defect mitigation technology using fiducial mark are defined.

36 MATERIALS SCIENCE↗

(2R)-4-Oxo-4[3-(Trifluoromethyl)-5,6-diihydro:1,2,4}triazolo[4,3-a}pyrazin-7(8H)-y1]-1-(2,4,5-trifluorophenyl)butan-2-amine: A Potent, Orally Active Dipeptidyl Peptidase IV Inhibitor for the Treatment of Type 2 Diabetes

A novel series of {beta}-amino amides incorporating fused heterocycles, i.e., triazolopiperazines, were synthesized and evaluated as inhibitors of dipeptidyl peptidase IV (DPP-IV) for the treatment of type 2 diabetes. (2R)-4-Oxo-4-[3-(trifluoromethyl)-5,6-dihydro[1,2,4]triazolo[4,3-a]pyrazin-7(8H)-yl]-1-(2,4,5-trifluorophenyl)butan-2-amine (1) is a potent, orally active DPP-IV inhibitor (IC{sub 50} = 18 nM) with excellent selectivity over other proline-selective peptidases, oral bioavailability in preclinical species, and in vivo efficacy in animal models. MK-0431, the phosphate salt of compound 1, was selected for development as a potential new treatment for type 2 diabetes.

60 APPLIED LIFE SCIENCES↗

The Different Impacts of SO2 and SO3 on Cu/Zeolite SCR Catalysts

The different impacts of SO2 and SO3 on Cu/zeolite SCR catalysts were investigated by SCR performance tests and multiple characterization techniques including temperature programmed desorption (TPD), X-ray photoelectron spectroscopy (XPS) and X-ray absorption fine structure (XAFS). The results indicate that a larger amount of highly dispersed CuSO4 formed in the zeolite catalysts (Z-CuSO4) upon SO3 poisoning, explaining the much more significant deactivation of the Cu/zeolite catalysts that were exposed to SO3 compared to poisoning by SO2. This paper provides the first demonstration that active sites of Cu/zeolite SCR catalysts involved in the storage and removal of sulfur can react with SO2 and SO3 in very different ways. In particular, the significant differences in the extent of sulfur uptake account for the considerably different impacts of SO2 and SO3 poisoning on the performance of Cu/zeolite SCR catalysts.

01 COAL, LIGNITE, AND PEAT↗

Printability and inspectability of programmed pit defects on teh masks in EUV lithography

Printability and inspectability of phase defects in ELlVL mask originated from substrate pit were investigated. For this purpose, PDMs with programmed pits on substrate were fabricated using different ML sources from several suppliers. Simulations with 32-nm HP L/S show that substrate pits with below {approx}20 nm in depth would not be printed on the wafer if they could be smoothed by ML process down to {approx}1 nm in depth on ML surface. Through the investigation of inspectability for programmed pits, minimum pit sizes detected by KLA6xx, AIT, and M7360 depend on ML smoothing performance. Furthermore, printability results for pit defects also correlate with smoothed pit sizes. AIT results for pattemed mask with 32-nm HP L/S represents that minimum printable size of pits could be {approx}28.3 nm of SEVD. In addition, printability of pits became more printable as defocus moves to (-) directions. Consequently, printability of phase defects strongly depends on their locations with respect to those of absorber patterns. This indicates that defect compensation by pattern shift could be a key technique to realize zero printable phase defects in EUVL masks.

36 MATERIALS SCIENCE↗

Characteristics of Desulfation Behavior for Pre-Sulfated Pt-BaO/CeO2 Lean NOx Trap Catalysts: The Role of the CeO2 Support

The desulfation of pre-sulfated Pt-BaO/CeO2 lean NOx trap catalysts was investigated by H2 TPRX (temperature programmed reaction), in-situ TR-XRD (time-resolved X-ray diffraction) and in-situ S K-edge XANES (X-ray absorption near edge spectroscopy) techniques. Compared with Pt-BaO/Al2O3 materials, the reductive treatment in H2 for a CeO2 supported sample up to 1073 K hardly removes any sulfur species. However, the results of in-situ TR-XRD measurements demonstrate that the quantity of a BaS phase formed on Pt-BaO/CeO2 is much smaller than that on Pt-BaO/Al2O3, implying that the formation of BaS crystallites, which occurs during the reduction from sulfate (SO42-) to sulfide (S2-), is significantly suppressed in the CeO2-supported catalyst. As the desulfation temperature increases under reducing conditions (in H2), the in-situ S XANES spectra show that, compared with alumina-supported samples, the reduction temperature for sulfates (S6+) decreases by about 150 K. Concomitantly, the formation of sulfur species with lower oxidation states (S2- - S4+) is enhanced. The step jump of S XANES spectra before and after desulfation are very similar, implying that the amount of sulfur-containing species removed during the reductive treatment is negligible, in agreement with the results of H2 TPRX. These results suggest that H2S produced by the reduction of BaSO4 is readily re-adsorbed on the ceria support to form ceria-sulfur complexes (e.g. CeS2). The high affinity of ceria for H2S, combined with the ease of reducibility of the ceria support gives rise to various oxidation states of sulfur after high temperature H2 treatments. Thus, the results of this study clearly show that the ceria support strongly affects the overall desulfation mechanism. The intrinsic role of the ceria support during desulfation, and its effect on the overall NOx storage processes are discussed on the basis of the characterization results obtained here.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Upper Limits on the Number of Small Bodies in Sedna-Like Orbits by the TAOS Project

We present the results of a search for occultation events by objects at distances between 100 and 1000 AU in lightcurves from the Taiwanese-American Occultation Survey (TAOS). We searched for consecutive, shallow flux reductions in the stellar lightcurves obtained by our survey between 7 February 2005 and 31 December 2006 with a total of {approx} 4.5 x 10{sup 9} three-telescope simultaneous photometric measurements. No events were detected, allowing us to set upper limits on the number density as a function of size and distance of objects in Sedna-like orbits, using simple models.

99 GENERAL AND MISCELLANEOUS↗