Search NASA⌕ Search

Engineering topics

Kim, Geon-Bo

Publications and source records attributed to Kim, Geon-Bo.

LLNL measurements of thermally irradiated HEU sample and saltwater-matrixed HEU sample

Two scintillation vials, kindly provided by the PNNL team, were received in the LLNL radiochemistry building on June 10, 2024; one containing approximately 2 mL dissolved thermally-irradiated HEU, and the other containing dried salt from irradiated seawater. A quick, semiquantitative screening count of the salt showed that the activation product activities were very low, with the highest activity being ~1 Bq 24 Na. The dissolved HEU solution was transferred to a Prindle vial (LLNL standard counting geometry) and weighed. Approximately 2 mL 3 M HNO 3 was added so that the solution completely covered the bottom of the vial and Gamanal software would be able to accurately generate an efficiency curve. This sample, called “PNNLFP24” is the irradiated HEU solution received, gravimetrically diluted by a factor of 1.7356 ± 0.0003, and was sent for quick gamma counting prior to further modification. Meanwhile the salt was quantitatively transferred to a 250 mL polyethylene bottle and dissolved in 160 mL 3 M HNO 3 . After counting, 50 µL PNNLFP24 was aliquoted for Resonance Ionization Mass Spectrometry (RIMS) analysis, and then 10.0 mL of the salt solution (6.03% of the total salt, gravimetrically) was added to the remaining PNNLFP24 solution to make “PNNLFPSW24”. After weighing, two 100 µL aliquots were removed for RIMS and DES, and 3 mL was aliquoted for microfluidic chemistry. The remaining “PNNLFPSW24” solution was weighed and proceeded for singles and coincidence counting on the MCBOS system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Progress Toward Fast Decay Energy Spectroscopy for Actinide Analysis

Decay energy spectroscopy (DES) is an increasingly popular technique for measuring isotopic composition of actinide samples for nuclear safeguards applications. Current approaches for actinide DES utilize milligram-scale external gold absorbers (> 0.1 nJ/K) that are integrated with actinide samples through mechanical kneading and are thermally connected to microcalorimeters using indium or gold wire bonds. This leads to relatively slow sensor rise time and, consequently, limits counting speed to a few counts per second. We are developing faster metallic magnetic calorimeter-based DES by integrating actinide samples with magnetic sensor materials. This reduces signal rise time and enables high counting speed while maintaining the ability to knead the radioactive source with the absorber. We have measured signal rise time of 0.7 μs with a 1.5 mg external gold absorber using this approach. Here, we also demonstrated online DES operation using an Ortec DSPEC 50, a commercially available data acquisition system developed for semiconductor detectors.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Hunting Sub-GeV Dark Matter with Diamonds and Magnetic Microcalorimeters Principle

This project is to study feasibility of a new concept for the sub-GeV dark matter (DM) detection using diamond crystals and magnetic microcalorimeters (MMCs). Diamond crystals are made of low mass carbon constituent that maximize kinetic energy of nuclear recoils from sub-GeV DM scattering due to their relatively similar masses. MMC is employed as a sensitive phonon sensor to measure athermal phonons that are produced by DM scattering in diamond crystals with 100 ns timing resolution and ~10 eV energy resolution. MMC’s fast timing resolution allows high precision phonon pulse shape analysis to separate out unwanted background or noise signals in the low energy region at E < 1 keV. Especially, the low energy excess (LEE) problems have been reported in the dark matter detection community and the proposed diamond-MMC detector might be able to provide important information to understand the origins of LEE signals in DM detectors. In this project a diamond-MMC detector has been built for proof-of-concept experiments and athermal phonon collection efficiencies have been investigated for single crystal and poly-crystal chemical-vapour-diamonds (SC and PC CVDs) as well as reference sapphire crystals are tested in the same geometries to quatify athermal phonon propagation and their collection to the MMC phonon sensors. Athermal phonon collection efficiencies and their lifetime in the diamond and sapphire crystals are successfully measured in the same geometry and experimental setup for comparison. SC CVD crystals exhibit poorer performance than the sapphire reference crystals in athermal phonon collection, while the PC CVD crystal exhibit better result than the sapphire. PC CVD with MMC phonon sensors would be feasible for sub GeV DM detection.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Safeguards Technolgy Development Program FY2023 Mid-Year Report

We will develop specific aspects of ultra-high-resolution microcalorimetry that support IAEA NML needs in preparation for transfer of the technology. Two techniques will be considered: gamma spectroscopy for nondestructive isotopic analysis of milligram- to gram-scale uranium and plutonium samples, and decay energy spectroscopy (DES) for isotopic analysis of specially prepared nanogram- to microgram-scale samples of alpha decaying actinides.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development of Fast Decay-Energy Spectroscopy With Magnetic Microcalorimeters

Decay energy spectroscopy (DES) is an increasingly important radiometric technique arising from the unique thermal detection physics and the precision of low-temperature microcalorimetry. DES can enable high-precision analysis of very small amounts of radioactive material with simple and rapid sample preparation, making it a key new tool for nuclear safeguards, nuclear forensics, the improvement of nuclear data, measurements of absolute activity, and other applications. For problems in nuclear safeguards and nuclear forensics it is highly desirable to increase the count rates achievable in DES, while maintaining simple and rapid sample preparation. Here, in this report, we describe progress in a new project to achieve high count rates in DES by taking advantage of the physics of magnetic microcalorimetry. We describe the results of initial modeling and experiment to validate the idea, a sample fabrication technique suitable for nuclear materials laboratories, the preparation and initial tests of paramagnetic Au-Er alloy in thin foil form, and the development of a sensing coil geometry that will perform well with the increased-thickness sensor used in the new technique.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗