TU-CD-207-05: A Novel Digital Tomosynthesis System Using Orthogonal Scanning Technique: A Feasibility Study

Purpose: As an alternative to full tomographic imaging technique such as cone-beam computed tomography (CBCT), there is growing interest to adopt digital tomosynthesis (DTS) for the use of diagnostic as well as therapeutic applications. The aim of this study is to propose a new DTS system using novel orthogonal scanning technique, which can provide superior image quality DTS images compared to the conventional DTS scanning system. Methods: Unlike conventional DTS scanning system, the proposed DTS is reconstructed with two sets of orthogonal patient scans. 1) X-ray projections that are acquired along transverse trajectory and 2) an additional sets of X-ray projections acquired along the vertical direction at the mid angle of the previous transverse scan. To reconstruct DTS, we have used modified filtered backprojection technique to account for the different scanning directions of each projection set. We have evaluated the performance of our method using numerical planning CT data of liver cancer patient and a physical pelvis phantom experiment. The results were compared with conventional DTS techniques with single transverse and vertical scanning. Results: The experiments on both numerical simulation as well as physical experiment showed that the resolution as well as contrast of anatomical structures was much clearer using our method. Specifically, the image quality comparing with transversely scanned DTS showed that the edge and contrast of anatomical structures along Left-Right (LR) directions was comparable however, considerable discrepancy and enhancement could be observed along Superior-Inferior (SI) direction using our method. The opposite was observed when vertically scanned DTS was compared. Conclusion: In this study, we propose a novel DTS system using orthogonal scanning technique. The results indicated that the image quality of our novel DTS system was superior compared to conventional DTS system. This makes our DTS system potentially useful in various on-line clinical applications.

60 APPLIED LIFE SCIENCES↗

WE-D-BRA-03: Four-Dimensional Dose Reconstruction Through Retrospective Phase Determination Using Cine Images of Electronic Portal Imaging Device

Purpose: To test a method to reconstruct a four-dimensional (4D) dose distribution using the correlation of pre-calculated 4D electronic portal imaging device (EPID) images and measured cine-EPID images. Methods: 1. A phantom designed to simulate a tumor in lung (a polystyrene block with 3.0 cm diameter embedded in cork) was placed on a sinusoidally moving platform with 2 cm amplitude and 4 sec/cycle. Ten-phase 4D CT images were acquired for treatment planning and dose reconstruction. A 6MV photon beam was irradiated on the phantom with static (field size=5×8.5 cm{sup 2}) and dynamic fields (sliding windows, 10×10 cm{sup 2}, X1 MLC closing in parallel with the tumor movement). 2. 4D and 3D doses were calculated forwardly on PTV (1 cm margin). 3. Dose images on EPID under the fields were calculated for 10 phases. 4. Cine EPID images were acquired during irradiation. 5. Their acquisition times were correlated to the phases of the phantom at which irradiation occurred by inter-comparing calculated “reference” EPID images with measured images (2D gamma comparison). For the dynamic beam, the tumor was hidden under MLCs during a portion of irradiation time; the correlation performed when the tumor was visible was extrapolated. 6. Dose for each phase was reconstructed on the 4D CT images and summed over all phases. The summation was compared with forwardly calculated 4D and 3D dose distributions. Monte Carlo methods were used for all calculations. Results: For the open and dynamic beams, the 4D reconstructed doses showed the pass rates of 92.7 % and 100 %, respectively, at the isocenter plane given 3% / 3 mm criteria. The better agreement of the dynamic beam was from its dose gradient which blurred the otherwise sharp difference between forward and reconstructed doses. This also contributed slightly better agreement in DVH of PTV. Conclusion: The feasibility of 4D reconstruction was demonstrated.

60 APPLIED LIFE SCIENCES↗

A general framework for the assessment of solar fuel technologies

The conversion of carbon dioxide and water into fuels in a solar refinery presents a potential solution for reducing greenhouse gas emissions, while providing a sustainable source of fuels and chemicals. Towards realizing such a solar refinery, there are many technological advances that must be met in terms of capturing and sourcing the feedstocks (namely CO2, H2O, and solar energy) and in catalytically converting CO2 and H2O. In the first part of this paper, we review the state-of-the-art in solar energy collection and conversion to solar utilities (heat, electricity, and as a photon source for photo-chemical reactions), CO2 capture and separation technology, and non-biological methods for converting CO2 and H2O to fuels. The two principal methods for CO2 conversion include (1) catalytic conversion using solar-derived hydrogen and (2) direct reduction of CO2 using H2O and solar energy. Both hydrogen production and direct CO2 reduction can be performed electro-catalytically, photo-electrochemically, photo-catalytically, and thermochemically. All four of these methods are discussed. In the second part of this paper, we utilize process modeling to assess the energy efficiency and economic feasibility of a generic solar refinery. The analysis demonstrates that the realization of a solar refinery is contingent upon significant technological improvements in all areas described above (solar energy capture and conversion, CO2 capture, and catalytic conversion processes).

Herron, JA↗

Size- and Composition-Dependent Radio Frequency Magnetic Permeability of Iron Oxide Nanocrystals

We investigate the size- and composition-dependent ac magnetic permeability of superparamagnetic iron oxide nanocrystals for radio frequency (RF) applications. The nanocrystals are obtained through high-temperature decomposition synthesis, and their stoichiometry is determined by Mossbauer spectroscopy. Two sets of oxides are studied: (a) as-synthesized magnetite-rich and (b) aged maghemite nanocrystals. All nanocrystalline samples are confirmed to be in the superparamagnetic state at room temperature by SQUID magnetometry. Through the one-turn inductor method, the ac magnetic properties of the nanocrystalline oxides are characterized. In magnetite-rich iron oxide nanocrystals, size-dependent magnetic permeability is not observed, while maghemite iron oxide nanocrystals show clear size dependence. The inductance, resistance, and quality factor of hand-wound inductors with a superparamagnetic composite core are measured. The superparamagnetic nanocrystals are successfully embedded into hand-wound inductors to function as inductor cores.

Yun, H↗

BOILING AUGMENTATION WITH MICRO/NANOSTRUCTURED SURFACES: CURRENT STATUS AND RESEARCH OUTLOOK

Advances in the development of micro- and nanostructured surfaces have enabled tremendous progress in delineation of mechanisms in boiling heat transfer and have propelled the rapid enhancement of heat transfer rates. This area of research is poised to make great strides toward tailoring surface features to produce dramatically improved thermal performance. A workshop was held in April 2013 to provide a review of the current state-of-the-art and to develop near-term and long-term goals for the boiling augmentation community. A brief historical perspective and primary findings are presented in this article. Though impressive gains have been made in enhancement of boiling heat transport, there still remain several unknowns such as the mechanisms that affect critical heat flux and optimization of surfaces for boiling heat transport. The promise of improved spatial resolution of optical techniques should improve knowledge of near-surface mechanisms. Standardization of experimental test sections and procedures has emerged as a critical issue that needs to be addressed immediately.

Bhavnani, S↗

SU-E-CAMPUS-T-04: Measurement of Proton Pencil Beam Spot Profile Using Cherenkov Radiation in Two Dimensional Optical Fiber Arrays

Purpose: Proton therapy aims to deliver a high dose in a well-defined target volume while sparing the healthy surrounding tissues thanks to their inherent depth dose characteristic (Bragg peak). In proton therapy, several techniques can be used to deliver the dose into the target volume. The one that allows the best conformity with the tumor, is called PBS (Pencil Beam Scanning). The measurement of the proton pencil beam spot profile (spot size) and position is very important for the accurate delivery of dose to the target volume with a good conformity. Methods: We have developed a fine segmented detector array to monitor the PBS. A prototype beam monitor using Cherenkov radiation in clear plastic optical fibers (cPOF) has been developed for continuous display of the pencil beam status during the therapeutic proton Pencil Beam Scanning mode operation. The benefit of using Cherenkov radiation is that the optical output is linear to the dose. Pedestal substraction and the gain adjustment between channels are performed. Spot profiles of various pencil beam energies(100 MeV to 226 MeV) are measured. Two dimensional gaussian fit is used to analyze the beam width and the spot center. The results are compared with that of Lynx(Scintillator-based sensor with CCD camera) and EBT3 Film. Results: The measured gaussian widths using fiber array system changes from 13 to 5 mm for the beam energies from 100 to 226 MeV. The results agree well with Lynx and Film within the systematic error. Conclusion: The results demonstrate good monitoring capability of the system. Not only measuing the spot profile but also monitoring dose map by accumulating each spot measurement is available. The x-y monitoing system with 128 channel readout will be mounted to the snout for the in-situ real time monitoring.

07 ISOTOPE AND RADIATION SOURCES↗

SU-F-19A-09: Propagation of Organ at Risk Contours for High Dose Rate Brachytherapy Planning for Cervical Cancer: A Deformable Image Registration Comparison

Purpose: To compare the performance of two deformable image registration (DIR) algorithms for contour propagation and to evaluate the accuracy of DIR for use with high dose rate (HDR) brachytherapy planning for cervical cancer. Methods: Five patients undergoing HDR ring and tandem brachytherapy were included in this retrospective study. All patients underwent CT simulation and replanning prior to each fraction (3–5 fractions total). CT-to-CT DIR was performed using two commercially available software platforms: SmartAdapt, Varian Medical Systems (Demons) and Velocity AI, Velocity Medical Solutions (B-spline). Fraction 1 contours were deformed and propagated to each subsequent image set and compared to contours manually drawn by an expert clinician. Dice similarity coefficients (DSC), defined as, DSC(A,B)=2(AandB)/(A+B) were calculated to quantify spatial overlap between manual (A) and deformed (B) contours. Additionally, clinician-assigned visual scores were used to describe and compare the performance of each DIR method and ultimately evaluate which was more clinically acceptable. Scoring was based on a 1–5 scale—with 1 meaning, “clinically acceptable with no contour changes” and 5 meaning, “clinically unacceptable”. Results: Statistically significant differences were not observed between the two DIR algorithms. The average DSC for the bladder, rectum and rectosigmoid were 0.82±0.08, 0.67±0.13 and 0.48±0.18, respectively. The poorest contour agreement was observed for the rectosigmoid due to limited soft tissue contrast and drastic anatomical changes, i.e., organ shape/filling. Two clinicians gave nearly equivalent average scores of 2.75±0.91 for SmartAdapt and 2.75±0.94 for Velocity AI—indicating that for a majority of the cases, more than one of the three contours evaluated required major modifications. Conclusion: Limitations of both DIR algorithms resulted in inaccuracies in contour propagation in the pelvic region, thus hampering the clinical utility of this technology. Further work is required to optimize these algorithms and take advantage of the potential of DIR for HDR brachytherapy planning.

60 APPLIED LIFE SCIENCES↗

TH-A-BRF-03: Evaluation of Synthetic CTs Generated Using MR-SIM Data

Purpose: To describe and evaluate a novel algorithm for generating synthetic CT images from MR-SIM data for dose calculations in MR-only treatment planning. Methods: A voxel-based weighted summation method was implemented to generate synthetic CT (synCT) images. MR data were acquired using Philips 1.0T Panorama high-field open MR-SIM. Retrospective patient data from seven prostate patients and one brain patient (three lesions) enrolled in an IRB-approved study were used. 3D T1-weighted fast field echo and 3D T2-weighted turbo spin echo sequences were utilized for all patients. A 3D balanced turbo field echo sequence using spectral presaturation with inversion recovery was acquired for prostate patients, but 3D ultra-short echo time (UTE)-DIXON was instead acquired for the brain patient to amplify bone signal for semi-automatic bone segmentation. Weight optimization was performed using a training subset of patients. HU value differences between planning CT and synCTs were analyzed using mean absolute error (MAE). Original patient CT-based treatment plans were mapped onto synCTs, dose was recalculated using original leaf motion and MU values, and DRRs were generated. Dosevolume metrics and gamma analysis were used for dosimetric evaluation. Results: Average whole-body MAE of synCTs across all patients was 75+12 HU. In prostate cancer patients, average HU difference between planning and synCTs was 0.9±1.0% for soft tissue structures and 4.3±2.5% for bony structures. DRRs were generated from synCTs and qualitatively showed good geometric agreement with planning CT-generated DRRs. D99, mean dose, and maximum dose to CTV calculated using the synCT remained within 1.2% of planning CT-based dose calculations. All gamma analysis evaluated at 2%/2mm dose difference/distance to agreement) pass rates were greater than 95% with an average of 99.9±0.1% for prostate patients and 98.4±2.2% for three brain lesions. Conclusion: SynCTs were generated with clinically acceptable accuracy comparable to planning CTs, enabling dose computations for MR-only simulation. Research supported in part by a grant from Philips HealthCare (Best, Netherlands)

60 APPLIED LIFE SCIENCES↗

TH-A-BRF-12: Assessment of 4D-MRI for Robust Motion and Volume Characterization

Purpose: Precise radiation therapy for abdominal lesions is complicated by respiratory motion and poor soft tissue contrast from 4DCT whereas 4DMRI provides superior tissue discrimination. We evaluated a novel 4D-MRI algorithm for MR-SIM motion management. Methods: Respiratory-triggered, T2-weighted single-shot Turbo Spin Echo 4D-MRI was evaluated for open high-field 1.0T MR-SIM. A programmable platform pulled objects on a trolley ∼2 cm superior-inferior (S-I) for “regular” (sinusoidal, (1-cos{sup 2}), 3-5 second periods) and “irregular” breathing patterns (exaggerated (1-cos{sup 2}) and patient curves), while a respiratory waveform was generated via a pressure sensor device. Coronal 4D-MRIs (2–12;10 phases, TE/TR/α = 35−61/6100 ms/90°, voxel=1×1×4 mm{sup 3}) were acquired for 54 unique phantom cases. Abdominal 4D−MRIs were evaluated for 5 healthy volunteers and 1 liver cancer patient (6–10 phases, TE/TR/α = 30−96/4500−6100 ms/90°, voxel=1×1×5–10 mm{sup 3}) on an IRB-approved protocol. Duty cycle, scan time, and excursion were evaluated between phase acquisitions and compared to coronal cine-MRI (∼1 frame/sec). Maximum intensity projections (MIPs) were analyzed. Results: In phantom, average duty cycle was 42.6 ± 11.4% (range: 23.6–69.1%). Regular, periodic breathing (sinusoidal, (1-cos{sup 2})) yielded higher duty cycles than irregular (48.5% and 35.9%, respectively, p<0.001) and fast periods had higher duty cycles than slow (50.4% for 3s and 39.4% for 5s, p<0.001). ∼4-fold acquisition time increase was measured for 10-phase versus 2-phase. MIP renderings revealed that SI object extent was underestimated a maximum of 4% (3mm) and 8% (6mm) for cine and 2-phase 4D-MRI, respectively, with respect to 10-phases. However, this was waveform dependent. A highly irregular breathing volunteer yielded lowest duty cycle (23%) and longest 10-phase scan time (∼14 minutes), although 6-phase acquisition for a liver cancer patient was reasonable (50% and 7.4 minutes, respectively). Conclusion: 4D-MRI offers potential for excursion characterization, although results suggest the use of adequate phases is important. Further application and clinical validation are warranted. Research supported in part by a grant from Philips HealthCare (Best, Netherlands) and an Internal Mentored Grant from Henry Ford Health System.

60 APPLIED LIFE SCIENCES↗

TH-A-9A-03: Dosimetric Effect of Rotational Errors for Lung Stereotactic Body Radiotherapy

Purpose: To evaluate the dosimetric effects on target volume and organs at risk (OARs) due to roll rotational errors in treatment setup of stereotactic body radiation therapy (SBRT) for lung cancer. Methods: There were a total of 23 volumetric modulated arc therapy (VMAT) plans for lung SBRT examined in this retrospective study. Each CT image of VMAT plans was intentionally rotated by ±1°, ±2°, and ±3° to simulate roll rotational setup errors. The axis of rotation was set at the center of T-spine. The target volume and OARs in the rotated CT images were re-defined by deformable registration of original contours. The dose distributions on each set of rotated images were re-calculated to cover the planning target volume (PTV) with the prescription dose before and after the couch translational correction. The dose-volumetric changes of PTVs and spinal cords were analyzed. Results: The differences in D95% of PTVs by −3°, −2°, −1°, 1°, 2°, and 3° roll rotations before the couch translational correction were on average −11.3±11.4%, −5.46±7.24%, −1.11±1.38% −3.34±3.97%, −9.64±10.3%, and −16.3±14.7%, respectively. After the couch translational correction, those values were −0.195±0.544%, −0.159±0.391%, −0.188±0.262%, −0.310±0.270%, −0.407±0.331%, and −0.433±0.401%, respectively. The maximum dose difference of spinal cord among the 23 plans even after the couch translational correction was 25.9% at −3° rotation. Conclusions: Roll rotational setup errors in lung SBRT significantly influenced the coverage of target volume using VMAT technique. This could be in part compensated by the translational couch correction. However, in spite of the translational correction, the delivered doses to the spinal cord could be more than the calculated doses. Therefore if rotational setup errors exist during lung SBRT using VMAT technique, the rotational correction would rather be considered to prevent over-irradiation of normal tissues than the translational correction.

60 APPLIED LIFE SCIENCES↗

SU-C-BRF-03: PCA Modeling of Anatomical Changes During Head and Neck Radiation Therapy

Purpose: To develop principal component analysis (PCA) models from daily cone beam CTs (CBCTs) of head and neck (H and N) patients that could be used prospectively in adaptive radiation therapy (ART). Methods: : For 7 H and N patients, Pinnacle Treatment Planning System (Philips Healthcare) was used to retrospectively deformably register daily CBCTs to the planning CT. The number N of CBCTs per treatment course ranged from 14 to 22. For each patient a PCA model was built from the deformation vector fields (DVFs), after first subtracting the mean DVF, producing N eigen-DVFs (EDVFs). It was hypothesized that EDVFs with large eigenvalues represent the major anatomical deformations during the course of treatment, and that it is feasible to relate each EDVF to a clinically meaningful systematic or random change in anatomy, such as weight loss, neck flexion, etc. Results: DVFs contained on the order of 3×87×87×58=1.3 million scalar values (3 times the number of voxels in the registered volume). The top 3 eigenvalues accounted for ∼90% of variance. Anatomical changes corresponding to an EDVF were evaluated by generating a synthetic DVF, and applying that DVF to the CT to produce a synthetic CBCT. For all patients, the EDVF for the largest eigenvalue was interpreted to model weight loss. The EDVF for other eigenvalues appeared to represented quasi-random fraction-to-fraction changes. Conclusion: The leading EDVFs from single-patient PCA models have tentatively been identified with weight loss changes during treatment. Other EDVFs are tentatively identified as quasi-random inter-fraction changes. Clean separation of systematic and random components may require further work. This work is expected to facilitate development of population-based PCA models that can be used to prospectively identify significant anatomical changes, such as weight loss, early in treatment, triggering replanning where beneficial.

60 APPLIED LIFE SCIENCES↗

TH-C-12A-06: Feasibility of a MLC-Based Inversely Optimized Multi-Field Grid Therapy Technique

Purpose: Grid therapy (GT), which generates highly spatially modulated dose distributions, can deliver single- or hypo-fractionated radiotherapy for large tumors without causing significant toxicities. GT may be applied in combination with immunotherapy, in light of recent preclinical data of synergetic interaction between radiotherapy and immunotherapy. However, conventional GT uses only one field, which does not have the advantage of multi-fields in 3D conformal-RT or IMRT. We have proposed a novel MLC-based, inverse-planned multi-field 3D GT technique. This study aims to test its deliverability and dosimetric accuracy. Methods: A lattice of small spheres was created as the boost volume within a large target. A simultaneous boost IMRT plan with 8-Gy to the target and 20-Gy to the boost volume was generated in the Eclipse treatment planning system (AAA v10) with a HD120 MLC. Nine beams were used, and the gantry and couch angles were selected so that the spheres were perfectly aligned in every beams eye view. The plan was mapped to a phantom with dose scaled. EBT3 films were calibrated and used to measure the delivered dose. Results: The IMRT plan generated a highly spatially modulated dose distribution in the target. D95%, D50%, D5% for the spheres and the targets in Gy were 18.5, 20.0, 21.4 and 7.9, 9.8, 16.1, respectively. D50% for a 1cm ring 1cm outside the target was 2.9-Gy. Film dosimetry showed good agreement between calculated and delivered dose, with an overall gamma passing rate of 99.6% (3%/1mm). The point dose differences for different spheres varied from 1–6%. Conclusion: We have demonstrated the deliverability and dose calculation accuracy of the MLC-based inversely optimized multi-field GT technique, which achieved a brachytherapy-like dose distribution. Single-fraction high dose can be delivered to the spheres in a large target with minimal dose to the surrounding normal tissue.

60 APPLIED LIFE SCIENCES↗

SU-D-16A-01: A Novel Method to Estimate Normal Tissue Dose for Radiotherapy Patients to Support Epidemiologic Studies of Second Cancer Risk

Purpose: Patient cohort of second cancer study often involves radiotherapy patients with no radiological images available: We developed methods to construct a realistic surrogate anatomy by using computational human phantoms. We tested this phantom images both in a commercial treatment planning system (Eclipse) and a custom Monte Carlo (MC) transport code. Methods: We used a reference adult male phantom defined by International Commission on Radiological Protection (ICRP). The hybrid phantom which was originally developed in Non-Uniform Rational B-Spline (NURBS) and polygon mesh format was converted into more common medical imaging format. Electron density was calculated from the material composition of the organs and tissues and then converted into DICOM format. The DICOM images were imported into the Eclipse system for treatment planning, and then the resulting DICOM-RT files were imported into the MC code for MC-based dose calculation. Normal tissue doses were calculation in Eclipse and MC code for an illustrative prostate treatment case and compared to each other. Results: DICOM images were generated from the adult male reference phantom. Densities and volumes of selected organs between the original phantom and ones represented within Eclipse showed good agreements, less than 0.6%. Mean dose from Eclipse and MC code match less than 7%, whereas maximum and minimum doses were different up to 45%. Conclusion: The methods established in this study will be useful for the reconstruction of organ dose to support epidemiological studies of second cancer in cancer survivors treated by radiotherapy. We also work on implementing body size-dependent computational phantoms to better represent patient's anatomy when the height and weight of patients are available.

60 APPLIED LIFE SCIENCES↗

SU-E-J-32: Calypso(R) and Laser-Based Localization Systems Comparison for Left-Sided Breast Cancer Patients Using Deep Inspiration Breath Hold

Purpose: Our institution uses a manual laser-based system for primary localization and verification during radiation treatment of left-sided breast cancer patients using deep inspiration breath hold (DIBH). This primary system was compared with sternum-placed Calypso(R) beacons (Varian Medical Systems, CA). Only intact breast patients are considered for this analysis. Methods: During computed tomography (CT) simulation, patients have BB and Calypso(R) surface beacons positioned sternally and marked for free-breathing and DIBH CTs. During dosimetry planning, BB longitudinal displacement between free breathing and DIBH CT determines laser mark (BH mark) location. Calypso(R) beacon locations from the DIBH CT are entered at the Tracking Station. During Linac simulation and treatment, patients inhale until the cross-hair and/or lasers coincide with the BH Mark, which can be seen using our high quality cameras (Pelco, CA). Daily Calypso(R) displacement values (difference from the DIBH-CT-based plan) are recorded.The displacement mean and standard deviation was calculated for each patient (77 patients, 1845 sessions). An aggregate mean and standard deviation was calculated weighted by the number of patient fractions.Some patients were shifted based on MV ports. A second data set was calculated with Calypso(R) values corrected by these shifts. Results: Mean displacement values indicate agreement within 1±3mm, with improvement for shifted data (Table). Conclusion: Both unshifted and shifted data sets show the Calypso(R) system coincides with the laser system within 1±3mm, demonstrating either localization/verification system will Resultin similar clinical outcomes. Displacement value uncertainty unilaterally reduces when shifts are taken into account.

07 ISOTOPE AND RADIATION SOURCES↗