Use of regularized principal component analysis to model anatomical changes during head and neck radiation therapy for treatment adaptation and response assessment

Purpose: To develop standard (SPCA) and regularized (RPCA) principal component analysis models of anatomical changes from daily cone beam CTs (CBCTs) of head and neck (H&N) patients and assess their potential use in adaptive radiation therapy, and for extracting quantitative information for treatment response assessment. Methods: Planning CT images of ten H&N patients were artificially deformed to create “digital phantom” images, which modeled systematic anatomical changes during radiation therapy. Artificial deformations closely mirrored patients’ actual deformations and were interpolated to generate 35 synthetic CBCTs, representing evolving anatomy over 35 fractions. Deformation vector fields (DVFs) were acquired between pCT and synthetic CBCTs (i.e., digital phantoms) and between pCT and clinical CBCTs. Patient-specific SPCA and RPCA models were built from these synthetic and clinical DVF sets. EigenDVFs (EDVFs) having the largest eigenvalues were hypothesized to capture the major anatomical deformations during treatment. Results: Principal component analysis (PCA) models achieve variable results, depending on the size and location of anatomical change. Random changes prevent or degrade PCA’s ability to detect underlying systematic change. RPCA is able to detect smaller systematic changes against the background of random fraction-to-fraction changes and is therefore more successful than SPCA at capturing systematic changes early in treatment. SPCA models were less successful at modeling systematic changes in clinical patient images, which contain a wider range of random motion than synthetic CBCTs, while the regularized approach was able to extract major modes of motion. Conclusions: Leading EDVFs from the both PCA approaches have the potential to capture systematic anatomical change during H&N radiotherapy when systematic changes are large enough with respect to random fraction-to-fraction changes. In all cases the RPCA approach appears to be more reliable at capturing systematic changes, enabling dosimetric consequences to be projected once trends are established early in a treatment course, or based on population models.

60 APPLIED LIFE SCIENCES↗

Intrafraction Variability and Deformation Quantification in the Breast

Purpose: To evaluate intrafraction variability and deformation of the lumpectomy cavity (LC), breast, and nearby organs. Methods and Materials: Sixteen left-sided postlumpectomy and 1 bilateral breast cancer cases underwent free-breathing CT (FBCT) and 10-phase 4-dimensional CT (4DCT). Deformable image registration was used for deformation analysis and contour propagation of breast, heart, lungs, and LC between end-exhale and end-inhale 4DCT phases. Respiration-induced motion was calculated via centroid analysis. Two planning target volumes (PTVs) were compared: PTV{sub FBCT} from the FBCT volume with an isotropic 10 mm expansion (5 mm excursion and 5 mm setup error) and PTV{sub 4DCT} generated from the union of 4DCT contours with isotropic 5 mm margin for setup error. Volume and geometry were evaluated via percent difference and bounding box analysis, respectively. Deformation correlations between breast/cavity, breast/lung, and breast/heart were evaluated. Associations were tested between cavity deformation and proximity to chest wall and breast surface. Results: Population-based 3-dimensional vector excursions were 2.5 ± 1.0 mm (range, 0.8-3.8 mm) for the cavity and 2.0 ± 0.8 mm (range, 0.7-3.0 mm) for the ipsilateral breast. Cavity excursion was predominantly in the anterior and superior directions (1.0 ± 0.8 mm and −1.8 ± 1.2 mm, respectively). Similarly, for all cases, LCs and ipsilateral breasts yielded median deformation values in the superior direction. For 14 of 17 patients, the LCs and breast interquartile ranges tended toward the anterior direction. The PTV{sub FBCT} was 51.5% ± 10.8% larger (P<.01) than PTV{sub 4DCT}. Bounding box analysis revealed that PTV{sub FBCT} was 9.8 ± 1.2 (lateral), 9.0 ± 2.2 (anterior–posterior), and 3.9 ± 1.8 (superior–inferior) mm larger than PTV{sub 4DCT}. Significant associations between breast and cavity deformation were found for 6 of 9 axes. No dependency was found between cavity deformation and proximity to chest wall or breast surface. Conclusions: Lumpectomy cavity and breast deformation and motion demonstrated large variability. A PTV{sub 4DCT} approach showed value in patient-specific margins, particularly if robust interfraction setup analysis can be performed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Deformable image registration based automatic CT-to-CT contour propagation for head and neck adaptive radiotherapy in the routine clinical setting

Purpose: To evaluate the clinical potential of deformable image registration (DIR)-based automatic propagation of physician-drawn contours from a planning CT to midtreatment CT images for head and neck (H and N) adaptive radiotherapy. Methods: Ten H and N patients, each with a planning CT (CT1) and a subsequent CT (CT2) taken approximately 3–4 week into treatment, were considered retrospectively. Clinically relevant organs and targets were manually delineated by a radiation oncologist on both sets of images. Four commercial DIR algorithms, two B-spline-based and two Demons-based, were used to deform CT1 and the relevant contour sets onto corresponding CT2 images. Agreement of the propagated contours with manually drawn contours on CT2 was visually rated by four radiation oncologists in a scale from 1 to 5, the volume overlap was quantified using Dice coefficients, and a distance analysis was done using center of mass (CoM) displacements and Hausdorff distances (HDs). Performance of these four commercial algorithms was validated using a parameter-optimized Elastix DIR algorithm. Results: All algorithms attained Dice coefficients of >0.85 for organs with clear boundaries and those with volumes >9 cm{sup 3}. Organs with volumes <3 cm{sup 3} and/or those with poorly defined boundaries showed Dice coefficients of ∼0.5–0.6. For the propagation of small organs (<3 cm{sup 3}), the B-spline-based algorithms showed higher mean Dice values (Dice = 0.60) than the Demons-based algorithms (Dice = 0.54). For the gross and planning target volumes, the respective mean Dice coefficients were 0.8 and 0.9. There was no statistically significant difference in the Dice coefficients, CoM, or HD among investigated DIR algorithms. The mean radiation oncologist visual scores of the four algorithms ranged from 3.2 to 3.8, which indicated that the quality of transferred contours was “clinically acceptable with minor modification or major modification in a small number of contours.” Conclusions: Use of DIR-based contour propagation in the routine clinical setting is expected to increase the efficiency of H and N replanning, reducing the amount of time needed for manual target and organ delineations.

60 APPLIED LIFE SCIENCES↗

A novel approach for evaluation of prostate deformation and associated dosimetric implications in IGRT of the prostate

Purpose: Prostate deformation is assumed to be a secondary correction and is typically ignored in the planning target volume (PTV) margin calculations. This assumption needs to be tested, especially when planning margins are reduced with daily image-guidance. In this study, deformation characteristics of the prostate and seminal vesicles were determined, and the dosimetric impact on treatment plans with different PTV margins was investigated. Methods: Ten prostate cancer patients were retrospectively selected for the study, each with three fiducial markers implanted in the prostate. Two hundred CBCT images were registered to respective planning CT images using a B-spline-based deformable image registration (DIR) software. A manual bony anatomy-based match was first applied based on the alignment of the pelvic bones and fiducial landmarks. DIR was then performed. For each registration, deformation vector fields (DVFs) of the prostate and seminal vesicles (SVs) were quantified using deformation-volume histograms. In addition, prostate rotation was evaluated and compared with prostate deformation. For a patient demonstrating small and large prostate deformations, target coverage degradation was analyzed in each of three treatment plans with PTV margins of 10 mm (6 mm at the prostate/rectum interface), as well as 5, and 3 mm uniformly. Results: Deformation of the prostate was most significant in the anterior direction. Maximum prostate deformation of greater than 10, 5, and 3 mm occurred in 1%, 17%, and 76% of the cases, respectively. Based on DVF-histograms, DVF magnitudes greater than 5 and 3 mm occurred in 2% and 27% of the cases, respectively. Deformation of the SVs was most significant in the posterior direction, and it was greater than 5 and 3 mm in 7.5% and 44.9% of the cases, respectively. Prostate deformation was found to be poorly correlated with rotation. Fifty percent of the cases showed rotation with negligible deformation and 7% of the cases showed significant deformation with minimal rotation (<3°). Average differences in the D{sub 95} dose to the prostate + SVs between the planning CT and CBCT images was 0.4% ± 0.5%, 3.0% ± 2.8%, and 6.6% ± 6.1%, respectively, for the plans with 10/6, 5, and 3 mm margins. For the case with both a large degree of prostate deformation (≈10% of the prostate volume) and rotation (≈8°), D{sub 95} was reduced by 0.5% ± 0.1%, 6.8% ± 0.6%, and 20.9% ± 1.6% for 10/6, 5, and 3 mm margin plans, respectively. For the case with large prostate deformation but negligible rotation (<1°), D{sub 95} was reduced by 0.4 ± 0.3, 3.9 ± 1.0, and 11.5 ± 2.5 for 10/6, 5, and 3 mm margin plans, respectively. Conclusions: Prostate deformation over a course of fractionated prostate radiotherapy may not be insignificant and may need to be accounted for in the planning margin design. A consequence of these results is that use of highly reduced planning margins must be viewed with caution.

60 APPLIED LIFE SCIENCES↗

Image-Guided Localization Accuracy of Stereoscopic Planar and Volumetric Imaging Methods for Stereotactic Radiation Surgery and Stereotactic Body Radiation Therapy: A Phantom Study

Purpose: To evaluate the positioning accuracies of two image-guided localization systems, ExacTrac and On-Board Imager (OBI), in a stereotactic treatment unit. Methods and Materials: An anthropomorphic pelvis phantom with eight internal metal markers (BBs) was used. The center of one BB was set as plan isocenter. The phantom was set up on a treatment table with various initial setup errors. Then, the errors were corrected using each of the investigated systems. The residual errors were measured with respect to the radiation isocenter using orthogonal portal images with field size 3 x 3 cm{sup 2}. The angular localization discrepancies of the two systems and the correction accuracy of the robotic couch were also studied. A pair of pre- and post-cone beam computed tomography (CBCT) images was acquired for each angular correction. Then, the correction errors were estimated by using the internal BBs through fiducial marker-based registrations. Results: The isocenter localization errors ({mu} {+-}{sigma}) in the left/right, posterior/anterior, and superior/inferior directions were, respectively, -0.2 {+-} 0.2 mm, -0.8 {+-} 0.2 mm, and -0.8 {+-} 0.4 mm for ExacTrac, and 0.5 {+-} 0.7 mm, 0.6 {+-} 0.5 mm, and 0.0 {+-} 0.5 mm for OBI CBCT. The registration angular discrepancy was 0.1 {+-} 0.2{sup o} between the two systems, and the maximum angle correction error of the robotic couch was 0.2{sup o} about all axes. Conclusion: Both the ExacTrac and the OBI CBCT systems showed approximately 1 mm isocenter localization accuracies. The angular discrepancy of two systems was minimal, and the robotic couch angle correction was accurate. These positioning uncertainties should be taken as a lower bound because the results were based on a rigid dosimetry phantom.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prostate Localization on Daily Cone-Beam Computed Tomography Images: Accuracy Assessment of Similarity Metrics

Purpose: To evaluate different similarity metrics (SM) using natural calcifications and observation-based measures to determine the most accurate prostate and seminal vesicle localization on daily cone-beam CT (CBCT) images. Methods and Materials: CBCT images of 29 patients were retrospectively analyzed; 14 patients with prostate calcifications (calcification data set) and 15 patients without calcifications (no-calcification data set). Three groups of test registrations were performed. Test 1: 70 CT/CBCT pairs from calcification dataset were registered using 17 SMs (6,580 registrations) and compared using the calcification mismatch error as an endpoint. Test 2: Using the four best SMs from Test 1, 75 CT/CBCT pairs in the no-calcification data set were registered (300 registrations). Accuracy of contour overlays was ranked visually. Test 3: For the best SM from Tests 1 and 2, accuracy was estimated using 356 CT/CBCT registrations. Additionally, target expansion margins were investigated for generating registration regions of interest. Results: Test 1-Incremental sign correlation (ISC), gradient correlation (GC), gradient difference (GD), and normalized cross correlation (NCC) showed the smallest errors ({mu} {+-} {sigma}: 1.6 {+-} 0.9 {approx} 2.9 {+-} 2.1 mm). Test 2-Two of the three reviewers ranked GC higher. Test 3-Using GC, 96% of registrations showed <3-mm error when calcifications were filtered. Errors were left/right: 0.1 {+-} 0.5mm, anterior/posterior: 0.8 {+-} 1.0mm, and superior/inferior: 0.5 {+-} 1.1 mm. The existence of calcifications increased the success rate to 97%. Expansion margins of 4-10 mm were equally successful. Conclusion: Gradient-based SMs were most accurate. Estimated error was found to be <3 mm (1.1 mm SD) in 96% of the registrations. Results suggest that the contour expansion margin should be no less than 4 mm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analysis of deformable image registration accuracy using computational modeling

Computer aided modeling of anatomic deformation, allowing various techniques and protocols in radiation therapy to be systematically verified and studied, has become increasingly attractive. In this study the potential issues in deformable image registration (DIR) were analyzed based on two numerical phantoms: One, a synthesized, low intensity gradient prostate image, and the other a lung patient's CT image data set. Each phantom was modeled with region-specific material parameters with its deformation solved using a finite element method. The resultant displacements were used to construct a benchmark to quantify the displacement errors of the Demons and B-Spline-based registrations. The results show that the accuracy of these registration algorithms depends on the chosen parameters, the selection of which is closely associated with the intensity gradients of the underlying images. For the Demons algorithm, both single resolution (SR) and multiresolution (MR) registrations required approximately 300 iterations to reach an accuracy of 1.4 mm mean error in the lung patient's CT image (and 0.7 mm mean error averaged in the lung only). For the low gradient prostate phantom, these algorithms (both SR and MR) required at least 1600 iterations to reduce their mean errors to 2 mm. For the B-Spline algorithms, best performance (mean errors of 1.9 mm for SR and 1.6 mm for MR, respectively) on the low gradient prostate was achieved using five grid nodes in each direction. Adding more grid nodes resulted in larger errors. For the lung patient's CT data set, the B-Spline registrations required ten grid nodes in each direction for highest accuracy (1.4 mm for SR and 1.5 mm for MR). The numbers of iterations or grid nodes required for optimal registrations depended on the intensity gradients of the underlying images. In summary, the performance of the Demons and B-Spline registrations have been quantitatively evaluated using numerical phantoms. The results show that parameter selection for optimal accuracy is closely related to the intensity gradients of the underlying images. Also, the result that the DIR algorithms produce much lower errors in heterogeneous lung regions relative to homogeneous (low intensity gradient) regions, suggests that feature-based evaluation of deformable image registration accuracy must be viewed cautiously.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Seismic Energy Demand of Buckling-Restrained Braced Frames

In this study seismic analyses of steel structures were carried out to examine the effect of ground motion characteristics and structural properties on energy demands using 60 earthquake ground motions recorded in different soil conditions, and the results were compared with those of previous works. Analysis results show that ductility ratios and the site conditions have significant influence on input energy. The ratio of hysteretic to input energy is considerably influenced by the ductility ratio and the strong motion duration. It is also observed that as the predominant periods of the input energy spectra are significantly larger than those of acceleration response spectra used in the strength design, the strength demand on a structure designed based on energy should be checked especially in short period structures. For that reason framed structures with buckling-restrained-braces (BRBs) were designed in such a way that all the input energy was dissipated by the hysteretic energy of the BRBs, and the results were compared with those designed by conventional strength-based design procedure.

58 GEOSCIENCES↗

Examining Margin Reduction and Its Impact on Dose Distribution for Prostate Cancer Patients Undergoing Daily Cone-Beam Computed Tomography

Purpose: To examine the dosimetric impact of margin reduction and quantify residual error after three-dimensional (3D) image registration using daily cone-beam computed tomography (CBCT) for prostate cancer patients. Methods and Materials: One hundred forty CBCTs from 5 prostate cancer patients were examined. Two intensity-modulated radiotherapy plans were generated on CT simulation on the basis of two planning target volume (PTV) margins: 10 mm all around the prostate and seminal vesicles except 6 mm posteriorly (10/6) and 5 mm all around except 3 mm posteriorly (5/3). Daily CBCT using the Varian On-Board Imaging System was acquired. The 10/6 and 5/3 simulation plans were overlaid onto each CBCT, and each CBCT plan was calculated. To examine residual error, PlanCT/CBCT intensity-based 3D image registration was performed for prostate localization using center of mass and maximal border displacement. Results: Prostate coverage was within 2% between the 10/6 and 5/3 plans. Seminal vesicle coverage was reduced with the 5/3 plan compared with the 10/6 plan, with coverage difference within 7%. The 5/3 plan allowed 30-50% sparing of bladder and rectal high-dose regions. For residual error quantification, center of mass data show that 99%, 93%, and 96% of observations fall within 3 mm in the left-right, anterior-posterior, and superior-inferior directions, respectively. Maximal border displacement observations range from 79% to 99%, within 5 mm for all directions. Conclusion: Cone-beam CT dosimetrically validated a 10/6 margin when soft-tissue localization is not used. Intensity-based 3D image registration has the potential to improve target localization and to provide guidelines for margin definition.

62 RADIOLOGY AND NUCLEAR MEDICINE↗