Volatile and Nonvolatile Resistive Switching Coexistence in Conductive Point Hexagonal Boron Nitride Monolayer

Recently, we demonstrated the nonvolatile resistive switching effects of metal–insulator–metal (MIM) atomristor structures based on two-dimensional (2D) monolayers. However, there are many remaining combinations between 2D monolayers and metal electrodes; hence, there is a need to further explore 2D resistance switching devices from material selections to future perspectives. This study investigated the volatile and nonvolatile switching coexistence of monolayer hexagonal boron nitride (h-BN) atomristors using top and bottom silver (Ag) metal electrodes. Utilizing an h-BN monolayer and Ag electrodes, we found that the transition between volatile and nonvolatile switching is attributed to the thickness/stiffness of chain-like conductive bridges between h-BN and Ag surfaces based on the current compliance and atomristor area. Computations indicate a “weak” bridge is responsible for volatile switching, while a “strong” bridge is formed for nonvolatile switching. Further, the current compliance determines the number of Ag atoms that undergo dissociation at the electrode, while the atomristor area determines the degree of electric field localization that forms more stable conductive bridges. The findings of this study suggest that the h-BN atomristor using Ag electrodes shows promise as a potential solution to integrate both volatile neurons and nonvolatile synapses in a single neuromorphic crossbar array structure through electrical and dimensional designs.

2D material↗

An Experimental Feasibility Study on Applying Neutron Tomography to Encapsulated Spent Nuclear Fuel - 20050

Visual inspection makes easier to ensure the integrity and safety of spent nuclear fuel (SNF) than any classical techniques. Various classical techniques have been applied but there are no reliable methods to qualitatively and quantitatively verify spent fuel in dry storage. Thus, the present authors have developed the prototype safeguards apparatus for dry storage employing the array of He-4 gas scintillation detectors (S670E, Arktis Radiation Detectors Ltd., Switzerland), newly designed to simultaneously measure thermal and fast neutrons without any moderators. The S670E detector has a cylindrical shape with a diameter of 52 mm and active length of 600 mm (total length: 875 mm). The detector is filled by He-4 gas with an approximate pressure of 180 bar for fast neutron detection, and its inner wall is coated by Li-6 for thermal neutron detection. The scintillation lights generated via Li-6 nuclear reaction and elastic scattering are collected by 24 SiPMs linearly paired at the center of the detector. The detector delivers a TTL (Transistor-Transistor Logic) output for pulse readout and UART (Universal Asynchronous Receiver Transmitter) for device control. In order to assess feasibility of the apparatus, an experimental system has been designed, built, and optimized via computational studies. Cf-252 neutron sources and linearly arrayed detectors, working as a single detector, were occupied for this study due to the difficulties in working with SNF. The laboratory scale cask (diameter: 0.67 m, height: 1.5 m), minimized by a factor of 10 compared to the actual thickness of a commercial TN-32 cask, was also manufactured. The detector array was designed to rotate the lab-scale cask and obtain 36 image profiles at every 10 degrees. All profiles were aligned in single frame image called a sinogram, and the cross-sectional image was then fabricated by the inverse radon transform algorithm. These experiments have been repeated with different configurations and numbers of sources. Some gamma-ray sources were also measured with neutron sources in order to distinguish between neutron and gamma-ray pulses. Basically, a He-4 detector is designed to run on Linux OS so it is difficult to directly apply to Windows-based equipment widely used in S. Korea. Therefore, a new data acquisition board working on Windows OS was designed and built. The board mainly consists of FPGA (Field Programmable Gate Array) and SoC (System on Chip) for TTL pulse readout, sorting measured data, and transferring data to a user interface. In conclusion, the tomographic system at lab-scale has shown considerable potential to detect a partial or gross defect of encapsulated assemblies in dry storage. Next steps of this study will be to 1) repeatedly carry out experiments to demonstrate scientific reliability and validity, and 2) numerically integrate signals with weight factors to enhance the image quality since the suggested system based on passive interrogation method requires longer measurement time. Finally, the system will apply to a commercial dry storage phased out soon in S. Korea. (authors)

07 ISOTOPE AND RADIATION SOURCES↗