Optical Thomson Scattering to characterize Low-density Plasma on Mykonos
Explore the source record for details and available documents.
Engineering topics
Publications and source records attributed to Kimmel, Mark W..
Explore the source record for details and available documents.
Helium or neopentane can be used as surrogate gas fill for deuterium (D2) or deuterium-tritium (DT) in laser-plasma interaction studies. Surrogates are convenient to avoid flammability hazards or the integration of cryogenics in an experiment. To test the degree of equivalency between deuterium and helium, experiments were conducted in the Pecos target chamber at Sandia National Laboratories. Observables such as laser propagation and signatures of laser-plasma instabilities (LPI) were recorded for multiple laser and target configurations. It was found that some observables can differ significantly despite the apparent similarity of the gases with respect to molecular charge and weight. While a qualitative behaviour of the interaction may very well be studied by finding a suitable compromise of laser absorption, electron density, and LPI cross sections, a quantitative investigation of expected values for deuterium fills at high laser intensities is not likely to succeed with surrogate gases.
The Daedalus ultrafast x-ray imager is the latest generation in Sandia’s hybrid CMOS detector family. With three frames along an identical line of sight, 1 ns minimum integration time, a higher full well than Icarus, and added features, Daedalus brings exciting new capabilities to diagnostic applications in inertial confinement fusion and high energy density science. In this work, we present measurements of time response, dynamic range, spatial uniformity, pixel cross-talk, and absolute x-ray sensitivity using pulsed optical and x-ray sources. Here, we report a measured 1.5 Me — full well, pixel sensitivity at 9.58 × 10 —7 V/e — , and an estimate of spatial uniformity at ~5% across the sensor array.
Many experiments at Sandia’s Z Pulsed Power Facility require x-ray backlighting diagnostics to understand experiment performance. Due to limitations in present-day source/detection modalities, most x-ray diagnostics at Z are restricted to photon energies <20 keV, ultimately limiting the density, amount, and atomic number of targets diagnosable in experiments. These limitations force the use of low-Z materials like Beryllium, and they prevent acquisition of important backlighting data for materials/densities that are opaque to soft x-rays and where background emission from the Z load and transmission lines overwhelm diagnostics. In this LDRD project, we have investigated the design and development of a laser wakefield acceleration platform driven by the Z-Petawatt laser – a platform that would enable the generation of a pulsed, collimated beam of high energy x-rays up to 100 keV. Geometrical considerations for implementation on the Z Machine require the use of sacrificial mirrors, which have been tested in offline experiments in the Chama target chamber in building 983. Our results suggest the use of sacrificial mirrors would not necessarily inhibit the laser wakefield x-ray process, particularly with the benefits stemming from planned laser upgrades. These conclusions support the continuation of laser wakefield source research and the development of the necessary infrastructure to deliver the Z-Petawatt laser to the Z center section along the appropriate lines of sight. Ultimately, this new capability will provide unprecedented views through dense states of matter, enabling the use of previously incompatible target materials/designs, and uncovering a new set of observables accessible through diffraction and spectroscopy in the hard x-ray regime. These will amplify the data return on precious Z shots and enhance Sandia’s ability to investigate fundamental physics in support of national security.
The long-term x-ray diffraction (XRD) detector scheme compatible with Z-containment experiments will involve conversion of the diffracted x-rays to optical light, which will be transported away from the Z-Dynamic Materials Properties (DMP) load and detected on a fast-gated camera. In this so-called DIffraction SCintillator Optic (DISCO) scheme , the scintillator is coupled to a long, coherent imaging fiber bundle using a custom lens system with high numerical aperture. In addition, the DISCO diagnostic incorporates time-gating to allow measurement only during the short time window of the x-ray pulse in which XRD occurs, thereby significantly reducing unwanted background generated by the Z-DMP load. Dynamic compression experiments were performed at the Chama target chamber to evaluate the DISCO diagnostic . Specifically, a Zr sample was laser-shocked with the Chaco laser while the Z-Beamlet (ZBL) laser was used to generate x-rays, which enabled time-gated 6.7-keV XRD patterns from the compressed Zr sample to be obtained.
Abstract not provided.
Abstract not provided.