Open‐source photovoltaic model pipeline validation against well‐characterized system data

Abstract All freely available plane‐of‐array (POA) transposition models and photovoltaic (PV) temperature and performance models in pvlib‐python and pvpltools‐python were examined against multiyear field data from Albuquerque, New Mexico. The data include different PV systems composed of crystalline silicon modules that vary in cell type, module construction, and materials. These systems have been characterized via IEC 61853‐1 and 61853‐2 testing, and the input data for each model were sourced from these system‐specific test results, rather than considering any generic input data (e.g., manufacturer's specification [spec] sheets or generic Panneau Solaire [PAN] files). Six POA transposition models, 7 temperature models, and 12 performance models are included in this comparative analysis. These freely available models were proven effective across many different types of technologies. The POA transposition models exhibited average normalized mean bias errors (NMBEs) within ±3%. Most PV temperature models underestimated temperature exhibiting mean and median residuals ranging from −6.5°C to 2.7°C; all temperature models saw a reduction in root mean square error when using transient assumptions over steady state. The performance models demonstrated similar behavior with a first and third interquartile NMBEs within ±4.2% and an overall average NMBE within ±2.3%. Although differences among models were observed at different times of the day/year, this study shows that the availability of system‐specific input data is more important than model selection. For example, using spec sheet or generic PAN file data with a complex PV performance model does not guarantee a better accuracy than a simpler PV performance model that uses system‐specific data.

14 SOLAR ENERGY↗

Determining circuit model parameters from operation data for PV system degradation analysis: $\mathrm{PVPRO}$

Physics-based circuit parameters like series and shunt resistance are essential to provide insights into the degradation status of photovoltaic (PV) arrays. However, calculating these parameters typically requires a full current-voltage characteristic (I-V curve), the acquisition of which involves specific measurement devices and costly methods. Thus, I-V curves of the PV system level are often not available. Here this paper proposes a methodology (PVPRO) to estimate these I-V curve parameters using only operation (string-level DC voltage and current) and weather data (irradiance and temperature). PVPRO first performs multi-stage data pre-processing to remove noisy data. Next, the time-series DC data are used to fit an equivalent circuit single-diode model (SDM) to estimate the circuit parameters by minimizing the differences between the measured and estimated values. In this way, the time evolutions of the SDM parameters are obtained. We evaluate PVPRO on synthetic datasets and find an excellent estimation of both SDM and the key I-V parameters (e.g., open-circuit voltage, short-circuit current, maximum power, etc.) with an average relative error of 0.55%. The performance, especially the extracted degradation rate of parameters, is robust to various measurement noises and the presence of faults. In addition, PVPRO is applied to a 271 kW PV field system. The relative error between the real and estimated operation voltage and current is less than 1%, suggesting that degradation trends are well captured. PVPRO represents a promising open-source tool to extract the time-series degradation trends of key PV parameters from routine operation data.

14 SOLAR ENERGY↗

Arrhenius Analysis of the Degradation Modes in Emerging Photovoltaic Backsheets

With increasingly large-scale deployments of photovoltaic (PV) modules to meet global energy demands, interest in better establishing modules' lifespans is growing. We report on the performance of co-extruded polyolefin- (PO)-based backsheets as environmentally friendly alternatives to fluoropolymer-reinforced polyethylene-terephthalate (PET)-based backsheets using three hygrometric accelerated test conditions. After completing cumulative 4000 hours of aging, we analyzed data from electrical performance (I-V), surface roughness (gloss), and appearance (L, a*, b* color) characterizations to quantify degradation rates, quantify the corresponding activation energy, and cross-correlate between the characteristics examined, thereby providing insights into the relationship between physical characteristics and operating performance.

BackFLIP↗

Onymous early‐life performance degradation analysis of recent photovoltaic module technologies

Abstract The cost of photovoltaic (PV) modules has declined by 85% since 2010. To achieve this reduction, manufacturers altered module designs and bill of materials; changes that could affect module durability and reliability. To determine if these changes have affected module durability, we measured the performance degradation of 834 fielded PV modules representing 13 module types from 7 manufacturers in 3 climates over 5 years. Degradation rates ( Rd ) are highly nonlinear over time, and seasonal variations are present in some module types. Mean and median degradation rate values of −0.62%/year and −0.58%/year, respectively, are consistent with rates measured for older modules. Of the 23 systems studied, 6 have degradation rates that will exceed the warranty limits in the future, whereas 13 systems demonstrate the potential of achieving lifetimes beyond 30 years, assuming Rd trends have stabilized.

14 SOLAR ENERGY↗

Arrhenius Analysis of the Degradation Modes in BackFLIP Study of Emerging Photovoltaic Backsheets: Preprint

With increasingly large-scale deployments of photovoltaic (PV) modules to meet global energy demands, interest in better establishing module lifespans is growing. We report on the performance of co-extruded polyolefin- (PO) based backsheets as environmentally friendly alternatives to fluoropolymer-reinforced polyethylene-terephthalate- (PET)-based backsheets using three hygrometric accelerated test conditions. After completing 4000 cumulative hours of aging, we analyzed data from electrical performance (I-V), surface roughness (gloss), and appearance (L, a*, b* color) characterizations are analyzed to quantify degradation rates, quantify the corresponding activation energy, and cross-correlate between the characteristics examined, thereby providing insights into the relationship between physical characteristics and operating performance.

BackFLIP↗

BACKFLIP: Identification of Materials and Changes Upon Aging of Emerging Fluoropolymer-Free and Industry-Benchmark PV Backsheets

Extending lifetimes of photovoltaic (PV) modules and decreasing manufacturing and decommissioning costs are motivating research of novel PV module backsheet materials. Backsheet integrity is critical to the safety and performance of a PV module, however, the polymeric materials are often vulnerable to environmental degradation. The long-term durability of emerging polyolefin (PO) materials is being examined to inform regarding the possible replacement of laminated backsheets containing polyethylene terephthalate (PET) cores and fluoropolymer protective inner/outer layers. This study compares traditional PET-based backsheets with novel, co-extruded, and recyclable PO-based backsheets after being subjected to hygrometric and UV photolytic accelerated weathering. A large set of characterization methods will compare physical, chemical, structural, mechanical, and insulating properties of these backsheets and the resulting mini-module (MiMo) PV performances. The study of chemical composition, glass- and phase-transition temperatures, degree of crystallinity, and crystalline structure are described here.

mini-module↗

Project Accomplishments Summary - SC12/01790.00. Concentrating Photovoltaics Component and System Research

Sandia National Laboratories (Sandia) and Cool Earth Solar, Inc. (CES) collaborated to evaluate and validate a new Concentrating Photovoltaic (CPV) technology for the utility-scale power market. Project goals included demonstration of CES's tracking and energy production mechanism and operation in a realworld configuration to validate and evaluate mechanical reliability, uptime, operations and maintenance, and energy production models. The test facility was located at Sandia California’s Livermore Valley Open Campus (LVOC). The collaboration allowed CES to quickly move from design concept to system prototype deployment in an operational environment, with approximately 17kW of engineering samples deployed. However, economic pressure from inexpensive flat panel photovoltaic modules caused a major contraction in the broader CPV market. CES was ultimately unable to overcome this economic pressure and discontinued efforts to develop their novel CPV product.

14 SOLAR ENERGY↗

Pattern Effects of Soil on Photovoltaic Surfaces

The texture or patterning of soil on PV surfaces may influence light capture at various angles of incidence (AOI). Accumulated soil can be considered a microshading element, which changes with respect to AOI. Laboratory deposition of simulated soil was used to prepare test coupons for simultaneous AOI and soiling loss experiments. A mixed solvent deposition technique was used to consistently deposit patterned test soils onto glass slides. Transmission decreased as soil loading and AOI increased. Dense aggregates significantly decreased transmission. But, highly dispersed particles are less prone to secondary scattering, improving overall light collection. In order to test AOI losses on relevant systems, uniform simulated soil coatings were applied to split reference cells to further examine this effect. Finally, the measured optical transmission and area coverage correlated closely to the observed $I_{{rm SC}}$. Angular losses were significant at angles as low as 25°.

14 SOLAR ENERGY↗

Quantification of a Minimum Detectable Soiling Level to Affect Photovoltaic Devices by Natural and Simulated Soils

Here, we report that soil accumulation on photovoltaic (PV) modules presents a challenge to long-term performance prediction and lifetime estimates due to the inherent difficulty in quantifying small changes over an extended period. Low mass loadings of soil are a common occurrence but remain difficult to quantify. In order to more accurately describe the specific effects of sparse soil films on PV systems, we have expanded upon an earlier technique to measure the optical losses due to an artificially applied obscurant film. A synthetic soil analog was sprayed onto glass coupons at very brief intervals with a high-volume, low-pressure pneumatic sprayer. Light transmission through the grime film was evaluated using a quantum efficiency test stand and UV/vis spectroscopy. A 0.1-g/m 2 grime loading was determined to be the limit of mass measurement sensitivity, which is similar to some reports of daily soil accumulation. Predictable, linear decreases in transmission were observed for samples with a mass loading between 0.1 and 0.5 g/m 2 . A similar change was observed for soiled coupons from an outdoor monitoring station. Collected soil from the field coupons was analyzed to develop a compositional analog for indoor studies. Lastly, natural and synthetic soils produced similar decreases in transmission.

14 SOLAR ENERGY↗