Search NASA⌕ Search

Engineering topics

King, C

Publications and source records attributed to King, C.

Online, real-time analysis of highly complex processing streams: Quantification of analytes in Hanford tank sample

Processing of hazardous materials is a crucial example of where on-line monitoring can significantly reduce operation risk, cost, and time. This is particularly true in the case of the Hanford site, where nuclear materials from the cold war era are being processed for environmental cleanup efforts. In exceedingly complex streams such as those at Hanford, on-line and real-time monitoring can be a challenge due to complexity of signals. Further obstacles are imposed by the caustic nature of processing streams as well as the radiation damage inflicted on instruments and probes. On-line monitoring based on Raman spectroscopy enables the detection of many Hanford tank species of interest, and was demonstrated here on nine chemical species that comprise the majority of tank waste by volume, including Al(OH)4-, C2O42-, CO32-, CrO42-, NO32-, NO3-, OH-, PO43-, SO42-. Real-time analysis of Raman signal allows for immediate quantification of target analytes and was successfully accomplished through the use of chemometric models. Furthermore, irradiation tests reveal Raman monitoring systems can effectively continue to operate even after receiving 1·107 Rad of gamma dose. The on-line, real-time monitoring system developed here was successfully used to simultaneously quantify nine target analytes in a real samples collected from Hanford tank AP-105.

Lines, Amanda M.↗

SU-E-J-179: Prediction of Pelvic Nodal Coverage Using Mutual Information Between Cone-Beam and Planning CTs

Purpose: To investigate if pelvic nodal coverage for prostate patients undergoing intensity modulated radiotherapy (IMRT) can be predicted using mutual image information computed between planning and cone-beam CTs (CBCTs). Methods: Four patients with high-risk prostate adenocarcinoma were treated with IMRT on a Varian TrueBeam. Plans were designed such that 95% of the nodal planning target volume (PTV) received the prescription dose of 45 Gy (N=1) or 50.4 Gy (N=3). Weekly CBCTs (N=25) were acquired and the nodal clinical target volumes and organs at risk were contoured by a physician. The percent nodal volume receiving prescription dose was recorded as a ground truth. Using the recorded shifts performed by the radiation therapists at the time of image acquisition, CBCTs were aligned with the planning kVCT. Mutual image information (MI) was calculated between the CBCT and the aligned planning CT within the contour of the nodal PTV. Due to variable CBCT fields-of-view, CBCT images covering less than 90% of the nodal volume were excluded from the analysis, resulting in the removal of eight CBCTs. Results: A correlation coefficient of 0.40 was observed between the MI metric and the percent of the nodal target volume receiving the prescription dose. One patient's CBCTs had clear outliers from the rest of the patients. Upon further investigation, we discovered image artifacts that were present only in that patient's images. When those four images were excluded, the correlation improved to 0.81. Conclusion: This pilot study shows the potential of predicting pelvic nodal dosimetry by computing the mutual image information between planning CTs and patient setup CBCTs. Importantly, this technique does not involve manual or automatic contouring of the CBCT images. Additional patients and more robust exclusion criteria will help validate our findings.

60 APPLIED LIFE SCIENCES↗

Further developments in generating type-safe messaging

At ICALEPCS 09, we introduced a source code generator that allows processes to communicate safely using data types native to each host language. In this paper, we discuss further development that has occurred since the conference in Kobe, Japan, including the addition of three more client languages, an optimization in network packet size and the addition of a new protocol data type. The protocol compiler is continuing to prove itself as an easy and robust way to get applications written in different languages hosted on different computer architectures to communicate. We have two active Erlang projects that are using the protocol compiler to access ACNET data at high data rates. We also used the protocol compiler output to deliver ACNET data to an iPhone/iPad application. Since it takes an average of two weeks to support a new language, we're willing to expand the protocol compiler to support new languages that our community uses.

43 PARTICLE ACCELERATORS↗

ACYSYS in a box

The Accelerator Control System at Fermilab has evolved to enable this relatively large control system to be encapsulated into a 'box' such as a laptop. The goal was to provide a platform isolated from the 'online' control system. This platform can be used internally for making major upgrades and modifications without impacting operations. It also provides a standalone environment for research and development including a turnkey control system for collaborators. Over time, the code base running on Scientific Linux has enabled all the salient features of the Fermilab's control system to be captured in an off-the-shelf laptop. The anticipated additional benefits of packaging the system include improved maintenance, reliability, documentation, and future enhancements.

43 PARTICLE ACCELERATORS↗