Densification and microstructure features of lithium hydride fabrication

The manufacturing of lithium hydride (LiH) utilizing uniaxial pressing, which offers fabrication with tailorable properties via microstructure control, can lead to the expansion in application of LiH while bypassing the challenges presented by historical casting manufacturing techniques. Through control of consolidation conditions such as pressure, temperature, dwell time and powder load, the presented work highlights the densification of LiH, with an emphasis on quantifying oxygen content, for applications requiring a specific density range necessary for optimized material performance. Karl Fischer Titration and X-ray Diffraction proved useful in determining oxygen and phase content while Computed Tomography and Scanning Electron Microscopy provided structural analysis. The temperature dependent densification of LiH fit with an Arrhenius term resulted in an activation energy of 21.2 kJ/mol. Images of fractured surfaces of LiH pressed at 500 °C revealed drastic grain coarsening, aided by the presence of oxygen impurities.

36 MATERIALS SCIENCE↗

$In-situ$ synchrotron x-ray diffraction and thermal expansion of TiB2 up to ~3050 °C

There is an increasing interest in understanding the performance and properties of ultra-high temperature ceramics due to their high melting points (<3000 °C) that make them promising for extreme environment applications. In-situ high temperature X-ray diffraction experiments were performed on TiB 2 beads up to ~3050 °C. For these experiments, TiB 2 powders were fabricated into spherical beads via gel casting methods and densified in a high temperature graphite furnace. These sample beads were then levitated in a conical nozzle levitator with reducing atmosphere (3% H 2 -Ar) while being heated using a 400 W CO 2 laser. During levitation a collimated synchrotron X-ray source was used to perform in-situ, temperature-dependent structural characterizations. The anisotropic coefficients of thermal expansion of TiB 2 were characterized as a function of temperature up to ~3050 °C. Elucidation of these properties are critical for the advancement of TiB 2 ceramics and other transition metal di-borides for use in high temperature applications such as hypersonic platforms, nuclear reactors, and atmospheric re-entry.

36 MATERIALS SCIENCE↗

Moisture ingress in commercial steel drums: Water content determination, diffusion modelling and predicted permeation rates

Commercial steel drums underpin the global economy, playing a pivotal role in the storage and transportation of critical materials. Transported and stored materials, such as food, chemical and nuclear waste, can be sensitive to ambient conditions, particularly moisture that can enhance negative effects such as corrosion and material degradation. Although international standards and regulations are in place for the qualification of steel drums, there are no current testing requirements, established limits or boundaries for the permeation of moisture into the drums during transportation or storage. This work aims to provide insights into the moisture ingress over time into properly sealed steel drums and provides estimated moisture ingress rates over time through extrapolation. Water vapour transmission rate (WVTR) measurements through the gasket material at 10–40°C were 0.11–2.1 g/m 2 /day resulting in a permeation activation energy of 30.2 kJ/mol. Water sorption measurements and Karl Fischer titration (KFT) on ethylene propylene diene monomer (EPDM) gasket material revealed a decrease in equilibrium moisture saturation with increasing temperature. KFT measurements also revealed the presence of moisture within the adhesive and drum wall after exposure to ambient conditions. KFT and Fourier transform infrared spectroscopy (FTIR) show that moisture will desorb from the EPDM and drum wall after exposure to desiccating conditions, although a minimal amount of moisture will remain present. When sealed to the manufacturer's recommendations, the steel drums are effective in minimizing moisture ingress. In conclusion, in sealed empty drums, moisture ingress rates for 19-L drums were 0.4–1.5 mg/day at 25°C 15% relative humidity (RH) and increased to 7.1–8.8 mg/day at 40°C 90% RH, and moisture ingress rates for 210-L drums were 2.5 and 3.5 mg/day at field deployment conditions of 15.5°C 51.5% RH and 23°C 40% RH, respectively.

42 ENGINEERING↗

Bond valence sum analysis of pyrochlore oxides including the novel dielectric Te 6+ pyrochlores: A Bi M TeO 7-y ( A = Cd, Ca; M = Cr, Ga, Sc, In, Fe)

Bond valence sum analysis is a powerful tool used in evaluating and validating crystal structures; especially when those structures are complex in nature. The pyrochlore structure type is versatile in not only the unique bonding that it exhibits, but also in the properties that results from the structure. Here this paper aims to center the discussion of evaluating the pyrochlore structure using the bond valence sum method. In this study, novel quaternary pyrochlores with a general stoichiometry of ABiMTeO 7 (A = Cd, Ca; M = Cr, Ga, Sc, In, Fe) were synthesized and characterized for their structural, magnetic, and dielectric properties. Two representative compounds within this series of pyrochlores, BiCaFeTeO7 and BiCdFeTeO 7 , were structurally characterized utilizing a combination of high-resolution synchrotron X-ray diffraction and neutron diffraction revealing oxygen deficient pyrochlore systems which were off from the expected stoichiometry with respect to the M site. The A site of both pyrochlores were found to be moved off-center from the expected 16d site to the 96h displaced position at a magnitude of 0.25 Å and 0.22 Å for the Bi/Ca and Bi/Cd systems, respectively. These structures were evaluated using the bond valence sum method and compared with trends in the literature. The properties are also reported for the Bi/Ca system for the first time, showing relatively high dielectric constants with a low dielectric loss which are primarily independent of frequency and temperature. The magnetic measurements for the Bi/Ca system for the magnetic substitutions reveal a paramagnet and antiferromagnetic properties for the Fe and Cr analogs, respectively. The novel BiCaMTeO 7 quaternary pyrochlore system shows great promise as an emerging dielectric material.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗