Search NASA⌕ Search

Engineering topics

King, P.

Publications and source records attributed to King, P..

31 records · Page 2

Measurement of Double-Polarization Asymmetries in the Quasielastic He → 3 ( e → , e ' d ) Process

We present a precise measurement of double-polarization asymmetries in the 3 He(e,e'd) reaction. This particular process is a uniquely sensitive probe of hadron dynamics in 3He and the structure of the underlying electromagnetic currents. The measurements have been performed in and around quasi-elastic kinematics at Q 2 =0.25(GeV/c) 2 for missing momenta up to 270MeV/c. The asymmetries are in fair agreement with the state-of-the-art calculations in terms of their functional dependencies on pm and omega, but are systematically offset. Beyond the region of the quasi-elastic peak, the discrepancies become even more pronounced. Thus, our measurements have been able to reveal deficiencies in the most sophisticated calculations of the three-body nuclear system, and indicate that further refinement in the treatment of their two- and/or three-body dynamics is required.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Assessments of Potential Rock Coatings at Rocknest, Gale Crater with ChemCam

Many locations on Mars have low color contrast between the rocks and soils due to the rocks being "dusty"--basically having a surface that is spectrally similar to Martian soil. In general this has been interpreted as soil and/or dust clinging to the rock though either mechanical or electrostic processes. However, given the apparent mobility of thin films of water forming cemented soils on Mars and at Gale Crater, the possibility exists that some of these "dusty" surfaces may actually be coatings formed by thin films of water locally mobilizing soil/air fall material at the rock interface. This type of coating was observed by Spirit during an investigation of the rock Mazatzal which showed enhanced salts above "normal soil" and an enhancement of nano phase iron oxide that was ~ 10 micronmeters thick. We decided to use ChemCam to investigate the possibility of similar rock coatings forming at the Rocknest site at Gale Crater.

Gale Crater↗

New Precision Limit on the Strange Vector Form Factors of the Proton

The parity-violating cross-section asymmetry in the elastic scattering of polarized electrons from unpolarized protons has been measured at a four-momentum transfer squared Q 2 = 0.624 GeV 2 and beam energy E b = 3.48 GeV to be A PV = -23.80 ± 0.78 (stat) ± 0.36 (syst) parts per million. This result is consistent with zero contribution of strange quarks to the combination of electric and magnetic form factors G E s + 0.517 G M s = 0.003 ± 0.010 (stat) ± 0.004 (syst) ± 0.009 (ff), where the third error is due to the limits of precision on the electromagnetic form factors and radiative corrections. With this measurement, the world data on strange contributions to nucleon form factors are seen to be consistent with zero and not more than a few percent of the proton form factors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for Effects Beyond the Born Approximation in Polarization Transfer Observables in e-vectorp Elastic Scattering

Intensive theoretical and experimental efforts over the past decade have aimed at explaining the discrepancy between data for the proton electric to magnetic form factor ratio, G{sub E}/G{sub M}, obtained separately from cross section and polarization transfer measurements. One possible explanation for this difference is a two-photon-exchange contribution. In an effort to search for effects beyond the one-photon-exchange or Born approximation, we report measurements of polarization transfer observables in the elastic H(e-vector,e{sup '}p-vector) reaction for three different beam energies at a Q{sup 2}=2.5 GeV{sup 2}, spanning a wide range of the kinematic parameter {epsilon}. The ratio R, which equals {mu}{sub p}G{sub E}/G{sub M} in the Born approximation, is found to be independent of {epsilon} at the 1.5% level. The {epsilon} dependence of the longitudinal polarization transfer component P{sub l} shows an enhancement of (2.3{+-}0.6)% relative to the Born approximation at large {epsilon}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Recoil Polarization Measurements of the Proton Electromagnetic Form Factor Ratio to Q{sup 2}=8.5 GeV{sup 2}

Among the most fundamental observables of nucleon structure, electromagnetic form factors are a crucial benchmark for modern calculations describing the strong interaction dynamics of the nucleon's quark constituents; indeed, recent proton data have attracted intense theoretical interest. In this Letter, we report new measurements of the proton electromagnetic form factor ratio using the recoil polarization method, at momentum transfers Q{sup 2}=5.2, 6.7, and 8.5 GeV{sup 2}. By extending the range of Q{sup 2} for which G{sub E}{sup p} is accurately determined by more than 50%, these measurements will provide significant constraints on models of nucleon structure in the nonperturbative regime.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cross sections and Rosenbluth separations in {sup 1}H(e,e{sup '}K{sup +})LAMBDA up to Q{sup 2}=2.35 GeV{sup 2}

The kaon electroproduction reaction {sup 1}H(e,e{sup '}K{sup +})LAMBDA was studied as a function of the virtual-photon four-momentum, Q{sup 2}, total energy, W, and momentum transfer, t, for different values of the virtual-photon polarization parameter. Data were taken at electron beam energies ranging from 3.40 to 5.75 GeV. The center of mass cross section was determined for twenty-one kinematics corresponding to Q{sup 2} of 1.90 and 2.35 GeV{sup 2}, and the longitudinal, sigma{sub L}, and transverse, sigma{sub T}, cross sections were separated using the Rosenbluth technique at fixed W and t. The separated cross sections reveal a flat energy dependence at forward kaon angles not satisfactorily described by existing electroproduction models. Influence of the kaon pole on the cross sections was investigated by adopting an off-shell form factor in the Regge model, which better describes the observed energy dependence of sigma{sub T} and sigma{sub L}.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Characterization of an advanced focal plane for multispectral linear array (MLA) application

It is pointed out that the MLA instrument represents the next generation in the Landsat series of earth resources satellites. The MLA sensor concept utilizes a pushbroom scan mode to eliminate electromechanical scan mirrors, and the lower reliabililty and higher power dissipation which accompany their employment. The pushbroom scanner makes use of a linear array which consists generally of thousands of detectors oriented perpendicular to the along-track direction of the satellite. Test techniques have been developed for the measurement of the module parameters which are critical to MLA focal plane performance. These measurements include the determination of infrared responsivity, linearity over the dynamic range, temporal noise, and fixed pattern effects on each detector element of each module tested. Tests related to spectral response, crosstalk, and spot scan profiles are also conducted. A description is provided of the test equipment involved.

King, P.↗

Vectorcardiographic changes during extended space flight (M093): Observations at rest and during exercise

The objectives of Skylab Experiment M093 were to measure electrocardiographic signals during space flight, to elucidate the electrophysiological basis for the changes observed, and to assess the effect of the change on the human cardiovascular system. Vectorcardiographic methods were used to quantitate changes, standardize data collection, and to facilitate reduction and statistical analysis of data. Since the Skylab missions provided a unique opportunity to study the effects of prolonged weightlessness on human subjects, an effort was made to construct a data base that contained measurements taken with precision and in adequate number to enable conclusions to be made with a high degree of confidence. Standardized exercise loads were incorporated into the experiment protocol to increase the sensitivity of the electrocardiogram for effects of deconditioning and to detect susceptability for arrhythmias.

Smith, R. F.↗

Vectorcardiographic changes during extended space flight

To assess the effects of space flight on cardiac electrical properties, vectorcardiograms were taken on the 9 Skylab astronauts during the flights of 28, 59, and 84 days. The Frank lead system was used and observations were made at rest; during 25%, 50% and 75% of maximum exercise; during a short pulse of exercise (150 watts, 2 minutes); and after exercise. Data from 131 in-flight tests were analyzed by computer and compared to preflight and postflight values. Statistically significant increase in QRS vector magnitude (six of nine crewmen); T vector magnitude (five of nine crewmen); and resting PR interval duration (six of nine crewmen) occurred. During exercise the PR interval did not differ from preflight. Exercise heart rates inflight were the same as preflight, but increased in the immediate postflight period. With the exception of the arrhythmias, no deleterious vectorcardiographic changes were observed during the Skylab missions.

Smith, R. F.↗