Kinzey, Bruce R

Publications and source records attributed to Kinzey, Bruce R.

Laboratory Evaluation of LED T8 Replacement Lamp Products

A report on a lab setting analysis involving LED lamps intended to directly replace T8 fluorescent lamps (4') showing light output, power, and economic comparisons with other fluorescent options.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Demonstration Assessment of Light-Emitting Diode (LED) Parking Lot Lighting in Leavenworth, KS

This report describes the process and results of a demonstration of solid-state lighting (SSL) technology in a commercial parking lot lighting application, under the U.S. Department of Energy (DOE) Solid-State Lighting Technology GATEWAY Demonstration Program. The parking lot is for customers and employees of a Walmart Supercenter in Leavenworth, Kansas and this installation represents the first use of the LED Parking Lot Performance Specification developed by the DOE’s Commercial Building Energy Alliance. The application is a parking lot covering more than a half million square feet, lighted primarily by light-emitting diodes (LEDs). Metal halide wall packs were installed along the building facade. This site is new construction, so the installed baseline(s) were hypothetical designs. It was acknowledged early on that deviating from Walmart’s typical design would reduce the illuminance on the site. Walmart primarily uses 1000W pulse-start metal halide (PMH) lamps. In order to provide a comparison between both typical design and a design using conventional luminaires providing a lower illuminance, a 400W PMH design was also considered. As mentioned already, the illuminance would be reduced by shifting from the PMH system to the LED system. The Illuminating Engineering Society of North America (IES) provides recommended minimum illuminance values for parking lots. All designs exceeded the recommended illuminance values in IES RP-20, some by a wider margin than others. Energy savings from installing the LED system compared to the different PMH systems varied. Compared to the 1000W PMH system, the LED system would save 63 percent of the energy. However, this corresponds to a 68 percent reduction in illuminance as well. In comparison to the 400W PMH system, the LED system would save 44 percent of the energy and provide similar minimum illuminance values at the time of relamping. The LED system cost more than either of the PMH systems when comparing initial costs. However, when the life-cycle costs from energy and maintenance were factored into the scenario, the LED system had lower costs at the end of a 10-year analysis period. The LED system had a 6.1 year payback compared to the 1000W PMH system and a 7.5 year payback versus the 400W PMH system. The costs reflect high initial cost for the LED luminaire, plus more luminaires and (subsequently) more poles for the LED system. The other major issue affecting cost effectiveness was that Leavenworth, Kansas has very low electricity costs. The melded rate for this site was $0.056 per kWh for electricity. However, if the national electricity rate of $0.1022/kWh was used the payback would change to between four and five years for the LED system. This demonstration met the GATEWAY requirements of saving energy, matching or improving illumination, and being cost effective. The project also demonstrated that the Commercial Building Energy Alliance (CBEA) specification works in practice. Walmart appreciated having an entire site lighted by LEDs to gain more experience with the technology. Walmart is reviewing the results of the demonstration as they consider their entire real estate portfolio.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Demonstration Assessment of Light-Emitting Diode (LED) Street Lighting Host Site: Lija Loop, Portland, Oregon

This report describes the process and results of a demonstration of solid-state lighting (SSL) technology in a residential street lighting application, under the U.S. Department of Energy GATEWAY Solid-State Lighting Technology Demonstration Program. In this project, eight 100W (nominal) high-pressure sodium cobra head fixtures were replaced with a like number of LED street light luminaires manufactured by Leotek, Inc. The Leotek product achieved an estimated payback in the Lija Loop installation of about 20 years for replacement scenarios and a much shorter 7.6 years for new installations. Much of the associated energy savings (55%) supporting these payback periods, however, were achieved by reducing average horizontal photopic illuminance a similar amount (53%). Examined from a different perspective, the measured performance suggests that the Leotek product is at approximate parity with the HPS cobra head in terms of average delivered photopic illumination for a given power consumption. HPS comprises the second most efficacious street lighting technology available, exceeded only by low pressure sodium (LPS). LPS technology is not considered suitable for most street lighting applications due to its monochromatic spectral output and poor color rendering ability; therefore, this LED product is performing at an efficiency level comparable to its primary competition in this application.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Demonstration Assessment of Light-Emitting Diode (LED) Roadway Lighting at the I-35W Bridge, Minneapolis, MN

This report describes the process and results of a demonstration of solid-state lighting (SSL) technology conducted in 2009 at the recently reconstructed I-35W bridge in Minneapolis, MN. The project was supported under the U.S. Department of Energy (DOE) Solid-State Lighting GATEWAY Technology Demonstration Program. Other participants in the demonstration project included the Minnesota Department of Transportation (Mn/DOT), Federal Highways Administration (FHWA), and BetaLED™ (a division of Ruud Lighting). Pacific Northwest National Laboratory (PNNL) conducted the measurements and analysis of the results. DOE has implemented a three-year evaluation of the LED luminaires in this installation in order to develop new longitudinal field data on LED performance in a challenging, real-world environment. This document provides information through the initial phase of the I-35W bridge project, up to and including the opening of the bridge to the public and the initial feedback received on the LED lighting installation from bridge users. Initial findings of the evaluation are favorable, with minimum energy savings level of 13% for the LED installation relative to the simulated base case using 250W high-pressure sodium (HPS) fixtures. The LEDs had an average illuminance level of 0.91 foot candles compared to 1.29 fc for the HPS lamps. The LED luminaires cost $38,000 more than HPS lamps, yielding a lengthy payback period, however the bridge contractor had offered to include the LED luminaires as part of the construction package at no additional cost. One potentially significant benefit of the LEDs in this installation is avoiding rolling lane closures on the heavily-traveled interstate bridge for the purpose of relamping the HPS fixtures. Rolling lane closures involve multiple crew members and various maintenance and safety vehicles, diversion of traffic, as well as related administrative tasks (e.g., approvals, scheduling, etc.). Mn/DOT records show an average cost of relamping fixtures along interstate roadways of between $130-150 per pole. The previous bridge saw a lamp mortality rate of approximately 50% every two years, though the new bridge was designed to minimize many of the vibration issues. A voluntary Web-based feedback survey of nearly 500 self-described bridge users showed strong preference for the LED lighting - positive comments outnumbered negative ones by about five-to-one.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Lighting the Great Outdoors: LEDs in Exterior Applications

Recent progress in the development of white light LEDs promises great impact by opening up the huge potential for LED illumination in new areas. One such area is general illumination for exterior applications. For example, there are an estimated combined 60.5 million roadway and parking installations in the U.S. These lights account for an estimated 53.3 TWh of electricity usage annually -- nearly 7% of all lighting. If LEDs could provide the same light performance with just 25% greater efficiency, savings of over 13 TWh could be achieved. In 2007, the authors assessed emerging LED lighting technologies in a parking garage and on a city street. The purpose of these tests was to enable a utility to determine whether energy efficiency programs promoting white light LED products might be justified. The results have supported the great promise of LEDs in exterior applications, while also highlighting the barriers that continue to hinder their widespread adoption. Such barriers include 1) inconsistent product quality across manufacturers; 2) lack of key metrics for comparing LEDs to conventional sources; and 3) high upfront cost of LED luminaires compared to conventional luminaires. This paper examines these barriers, ways in which energy-efficiency programs could help to overcome them, and the potential for energy and financial savings from LED lighting in these two exterior applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Demonstration Assessment of Light Emitting Diode (LED) Walkway Lighting at the Federal Aviation Administration William J. Hughes Technical Center, in Atlantic City, New Jersey

This report documents the results of a collaborative project to demonstrate a solid state lighting (SSL) general illumination product in an outdoor area walkway application. In the project, six light-emitting diode (LED) luminaires were installed to replace six existing high pressure sodium (HPS) luminaires mounted on 14-foot poles on a set of exterior walkways and stairs at the Federal Aviation Administration (FAA) William J. Hughes Technical Center in Atlantic City, New Jersey, during December, 2007. The effort was a U.S. Department of Energy (DOE) SSL Technology Gateway Demonstration that involved a collaborative teaming agreement between DOE, FAA and Ruud Lighting (and their wholly owned division, Beta LED). Pre- and post-installation power and illumination measurements were taken and used in calculations of energy savings and related economic payback, while personnel impacted by the new lights were provided questionnaires to gauge their perceptions and feedback. The SSL product demonstrated energy savings of over 25% while maintaining illuminance levels and improving illuminance uniformity. PNNL's economic analysis yielded a variety of potential payback results depending on the assumptions used. In the best case, replacing HPS with the LED luminaire can yield a payback as low as 3 years. The new lamps were quite popular with the affected personnel, who gave the lighting an average score of 4.46 out of 5 for improvement.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

INCIDENT REPORTING: LEARNING FROM EXPERIENCE

Experience makes a superior teacher. Sharing the details surrounding safety events is one of the best ways to help prevent their recurrence elsewhere. This approach requires an open, non-punitive environment to achieve broad benefits. The Hydrogen Incident Reporting Tool (www.h2incidents.org) is intended to facilitate the sharing of lessons learned and other relevant information gained from actual experiences using and working with hydrogen and hydrogen systems. Its intended audience includes those involved in virtually any aspect of hydrogen technology, systems and use, with an emphasis towards energy and transportation applications. The database contains records of safety events both publicly available and/or voluntarily submitted. Typical records contain a general description of the occurrence, contributing factors, equipment involved, and some detailing of consequences and changes that have been subsequently implemented to prevent recurrence of similar events in the future. The voluntary and confidential nature and other characteristics surrounding the database mean that any analysis of apparent trends in its contents cannot be considered statistically valid for a universal population. A large portion of reported incidents have occurred in a laboratory setting due to the typical background of the reporting projects, for example. Yet some interesting trends are becoming apparent even at this early stage of the database’s existence and general lessons can already be taken away from these experiences. This paper discusses the database and a few trends that have already become apparent for the reported incidents. Anticipated future uses of this information are also described. This paper is intended to encourage wider participation and usage of the incidents reporting database and to promote the safety benefits offered by its contents.

08 HYDROGEN↗