Search NASA⌕ Search

Engineering topics

Kiriyama, H

Publications and source records attributed to Kiriyama, H.

Extreme field limits in the interaction of laser light with ultrarelativistic electrons

The critical electric field of quantum electrodynamics is so strong that it produces electron-positron pairs from vacuum, converting the energy of light into matter. This field has become feasible through the construction of extremely high power lasers or/and with the sophisticated use of nonlinear processes in relativistic plasmas. A feasibility of the experiments on the collision of laser light and high intensity electromagnetic pulses, generated by relativistic flying mirrors, with relativistic electrons for the studying of extreme field limits in the nonlinear interaction of electromagnetic waves is discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

X-ray emission from relativistically moving electron density cusps

We report on novel methods to generate ultra-short, coherent, X-rays using a laserplasma interaction. Nonlinear interaction of intense laser pulses with plasma creates stable, specific structures such as electron cusps. For example, wake waves excited in an underdense plasma by an intense, short-pulse laser become dense and propagate along with the laser pulse. This is called a relativistic flying mirror. The flying mirror can reflect a counter-propagating laser pulse and directly convert it into high-frequency radiation, with a frequency multiplication factor of {approx} 4{gamma}{sup 2} and pulse shortening with the same factor. After the proof-of-principle experiments, we observed that the photon number generated in the flying mirror is close to the theoretical estimate. We present the details of the experiment in which a 9 TW laser pulse focused into a He gas jet generated the Flying Mirror, which partly reflected a 1 TW pulse, giving up to {approx} 10{sup 10} photons, 60 nJ (1.4 Multiplication-Sign 10{sup 12} photons/sr) in the XUV spectral region (12.8-22 nm).

07 ISOTOPE AND RADIATION SOURCES↗

The spectra of the multicharged argon hollow ions: Observation, modeling and using for diagnostics of the early stage of the heating of clusters by a super high contrast femtosecond laser pulses

A study is made of the ultra-short laser pulse irradiation of Ar cluster targets. Experiments have been performed with large cluster sizes and using very high laser contrasts, which have allowed clear and unambiguous observation of exotic inner-shell transitions in near-neutral Ar ions. The interaction of the main laser pulse with the unperturbed target is a necessary requirement for observing these lines. Our measurements are supported by kinetics calculations in which a very detailed atomic model is used. The calculations predict all of the spectral features found experimentally, and support the notion that the X-ray emission arises from many ion stages of the Ar plasma, from near-neutral through He-like ions, and from a range of plasma temperatures and densities. Differences between X-ray argon clusters excited at the laser-cluster and laser-droplet interactions have been analyzed. X-ray spectral methods have been proposed to determine the parameters of the plasma formed at the early stages of its evolution. It has been shown that the spectra of hollow ions are the most informative in the first moments of the heating of a cluster, whereas the diagnostics of the late stages can be performed using the conventional lines of multicharged ions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quantitative measurement of hard x-ray spectra for high intensity laser produced plasma

X-ray line spectra ranging from 17 to 77 keV were quantitatively measured with a Laue spectrometer, composed of a cylindrically curved crystal and a detector. Either a visible CCD detector coupled with a CsI phosphor screen or an imaging plate can be chosen, depending on the signal intensities and exposure times. The absolute sensitivity of the spectrometer system was calibrated using pre-characterized laser-produced x-ray sources and radioisotopes. The integrated reflectivity for the crystal is in good agreement with predictions by an open code for x-ray diffraction. The energy transfer efficiency from incident laser beams to hot electrons, as the energy transfer agency for specific x-ray line emissions, is derived as a consequence of this work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhancement of Photon Number Reflected by the Relativistic Flying Mirror

Laser light reflection by a relativistically moving electron density modulation (flying mirror) in a wake wave generated in a plasma by a high intensity laser pulse is investigated experimentally. A counterpropagating laser pulse is reflected and upshifted in frequency with a multiplication factor of 37-66, corresponding to the extreme ultraviolet wavelength. The demonstrated flying mirror reflectivity (from 3x10{sup -6} to 2x10{sup -5}, and from 1.3x10{sup -4} to 0.6x10{sup -3}, for the photon number and pulse energy, respectively) is close to the theoretical estimate for the parameters of the experiment.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electron Optical Injection with Head-On and Countercrossing Colliding Laser Pulses

A high stability electron bunch is generated by laser wakefield acceleration with the help of a colliding laser pulse. The wakefield is generated by a laser pulse; the second laser pulse collides with the first pulse at 180 deg. and at 135 deg. realizing optical injection of an electron bunch. The electron bunch has high stability and high reproducibility compared with single pulse electron generation. In the case of 180 deg. collision, special measures have been taken to prevent damage. In the case of 135 deg. collision, since the second pulse is countercrossing, it cannot damage the laser system.

43 PARTICLE ACCELERATORS↗

Laser driven proton beam for the applications: toward ultra-high intensity and short pulse proton beam

As a benchmark experiment to realize a novel and compact laser driven proton accelerator whose significant features are high number density in a short pulse width (approxns), 2.4 MeV laser driven proton beam is stably focused at 1 Hz repetition rate by using a pair of permanent quadrupole magnets (PMQs) with large apertures whose diameters and field strengths are 3.5 cm and 55 T/m for the first and 2.3 cm and 60 T/m for the second magnets, respectively. The proton beam has been focused to a focal spot of 3x8 mm{sup 2} in horizontal and vertical direction (full width at half maximum) at 650approxmm from the source, which is well reproduced by the simulation. The further optimization of the focusing system will sure to pave a way to the novel proton accelerator with which we can investigate the physics appeared in the short time scale as well as that in a high energy density matter, oncology, astrophysics, and so on.

43 PARTICLE ACCELERATORS↗

Contrast Effect on the Laser Injected Electron Beam

Laser-plasma interaction generates a high energy electron beam. The laser contrast ratio is one of the important parameters for laser acceleration due to pre-plasma effects. For the high laser contrast ratio, a 140 MeV monoenergetic electron beam with a charge of 100 pC is obtained. For the low laser contrast ratio; a low quality electron beam or no electron beam are generated, because the pre-pulse blowout plasma electrons and put into disorder the plasma before the main pulse interacting the plasma. The laser contrast ratio should be high in order to generate a high quality electron beam with a high charge.

43 PARTICLE ACCELERATORS↗

Radiobiological study by using laser-driven proton beams

Particle acceleration driven by high-intensity laser systems is widely attracting interest as a potential alternative to conventional ion acceleration, including ion accelerator applications to tumor therapy. Recent works have shown that a high intensity laser pulse can produce single proton bunches of a high current and a short pulse duration. This unique feature of laser-ion acceleration can lead to progress in the development of novel ion sources. However, there has been no experimental study of the biological effects of laser-driven ion beams. We describe in this report the first demonstrated irradiation effect of laser-accelerated protons on human lung cancer cells. In-vitro A549 cells are irradiated with a proton dose of 20 Gy, resulting in a distinct formation of gamma-H2AX foci as an indicator of DNA double-strand breaks. This is a pioneering result that points to future investigations of the radiobiological effects of laser-driven ion beams. The laser-driven ion beam is apotential excitation source for time-resolved determination of hydroxyl (OH) radical yield, which will explore relationship between the fundamental chemical reactions of radiation effects and consequent biological processes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

On-Target Contrast Diagnostic via Specular Reflectivity Measurement

High-power laser contrast is challenging to measure, especially in the real target irradiation conditions. We present a convenient and relatively simple contrast diagnostic technique based on the measurement of target specular reflectivity at full laser power. The reflectivity remains high even at intensities above 10{sup 19} W/cm{sup 2} in the case of a high-contrast prepulse-free laser. On the contrary, the specular reflectivity drops in the case of lower contrast, due to the beam break-up and increased absorption caused by the preformed plasma. The technique was demonstrated using three different laser systems with several contrast conditions: Astra (CLF, RAL), TiS laser at APRI, GIST, and J-KAREN (APRC, JAEA).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Application of laser-accelerated protons to the demonstration of DNA double-strand breaks in human cancer cells

We report the demonstrated irradiation effect of laser-accelerated protons on human cancer cells. In vitro (living) A549 cells are irradiated with quasimonoenergetic proton bunches of 0.8-2.4 MeV with a single bunch duration of 15 ns. Irradiation with the proton dose of 20 Gy results in a distinct formation of {gamma}-H2AX foci as an indicator of DNA double-strand breaks generated in the cancer cells. This is a pioneering result that points to future investigations of the radiobiological effects of laser-driven ion beams. Unique high-current and short-bunch features make laser-driven proton bunches an excitation source for time-resolved determination of radical yields.

61 RADIATION PROTECTION AND DOSIMETRY↗

Focusing and spectral enhancement of a repetition-rated, laser-driven, divergent multi-MeV proton beam using permanent quadrupole magnets

A pair of conventional permanent magnet quadrupoles is used to focus a 2.4 MeV laser-driven proton beam at a 1 Hz repetition rate. The magnetic field strengths are 55 and 60 T/m for the first and second quadrupoles, respectively. The proton beam is focused to a spot with a size of less than {approx}3x8 mm{sup 2} at a distance of 650 mm from the source. This result is in good agreement with the Monte Carlo particle trajectory simulation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Femtosecond laser driven high-flux highly collimated MeV-proton beam

Highlly collimated energetic protons whose energies are up to 4 MeV are generated by an intense femtosecond Titanium Sappheire laser pulse interacting with a 7.5, 12.5, and 25 {mu}m-thick Polyimide tape target and 5 {mu}m-thick copper target. We find no clear difference on the proton spectra from 7.5, 12.5, and 25 {mu}m Polyimide tape target. The highest conversion efficiency from laser energy into protons of {approx}3% is observed with a 7.5 {mu}m thick Polyimide target. The quality of the proton beam is good enough to obtain a clear projection image of a mesh having 10 {mu}m line and space structure, installed into the passage of the beam. We obtain clear vertical lines on the proton intensity profiles from the copper target, which are considered to be transferred from the surface of the copper target. From it, we can restrict the size of the proton emitting region to be {approx}20 {mu}m.

43 PARTICLE ACCELERATORS↗

Opportunities for TeV Laser Acceleration

A set of ballpark parameters for laser, plasma, and accelerator technologies that define for electron energies reaching as high as TeV are identified. These ballpark parameters are carved out from the fundamental scaling laws that govern laser acceleration, theoretically suggested and experimentally explored over a wide range in the recent years. In the density regime on the order of 10{sup 16} cm{sup -3}, the appropriate laser technology, we find, matches well with that of a highly efficient high fluence LD driven Yb ceramic laser. Further, the collective acceleration technique applies to compactify the beam stoppage stage by adopting the beam-plasma wave deceleration, which contributes to significantly enhance the stopping power and energy recovery capability of the beam. Thus we find the confluence of the needed laser acceleration parameters dictated by these scaling laws and the emerging laser technology. This may herald a new technology in the ultrahigh energy frontier.

43 PARTICLE ACCELERATORS↗

Efficient production of a collimated MeV proton beam from a polyimide target driven by an intense femtosecond laser pulse

High-flux energetic protons whose maximum energies are up to 4 MeV are generated by an intense femtosecond titanium:sapphire laser pulse interacting with 7.5, 12.5, and 25 {mu}m thick polyimide tape targets. Laser pulse with an energy of 1.7 J and with a duration of 34 fs is focused with an f/3.4 parabolic mirror giving an intensity of 3x10{sup 19} W cm{sup -2}. The main pulse to amplified spontaneous emission (ASE) intensity contrast ratio is 2.5x10{sup 7}. The conversion efficiency from the laser energy into the proton kinetic energies is achieved to be {approx}3%, which is comparable to or even higher than those achieved in the previous works; using nanometer-thick targets, in combination with the short-pulse lasers that have almost the same pulse width and the intensity but different main pulse to ASE intensity contrast of {approx}10{sup 10} [Neely et al., Appl. Phys. Lett. 89, 021502 (2006)], in which the authors claim that the main mechanism is target normal sheath acceleration; or using the 7.5 {mu}m thick polyimide target, in combination with the short-pulse laser, which has almost the same pulse width and the intensity, but the main pulse to ASE intensity contrast ratio was controlled to be 2.5x10{sup 5} [Yogo et al., Phys. Rev. E 77, 016401 (2008)], in which the authors claim the efficient acceleration by the mechanism of the underdense plasma model. The contrast ratio of the present experiment is in between these two experiments. The possible mechanism of this regime is discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗