Search NASA⌕ Search

Engineering topics

Kirsch, K. J.

Publications and source records attributed to Kirsch, K. J..

Single particle aerodynamic relaxation time analyzer

An instrument employing a laser Doppler velocimeter and a microphone to measure the phase lag of the motion of aerosol particulates relative to the motion of the fluid medium within an acoustic field is described. The relaxation times and aerodynamic diameters of the particles or droplets are determined in real time from the measured values of phase lag; thus, the size analysis is independent of the electrostatic charges and refractive indices of the particulates. The instrument is suitable for analyzing the aerodynamic size spectrum of atmospheric particulate pollutants with aerodynamic diameters ranging from 0.1 to 10.0 microns.

Mazumder, M. K.↗

Wind tunnel flow seeding for laser velocimetry applications

Flow-seeding requirements for wind tunnel studies of subsonic and transonic flow fields are discussed with reference to laser velocimeter applications. Design of an aerosol generator with an output flow rate of 60 scfm is presented. The generated aerosol is fairly monodisperse; tracer particle diameter can be varied from 0.2 to 0.5 micron; and seeding density can be varied from 100 to 10,000 particles/cu sec. Experimental data on the use of this aerosol generator with various aerosol injection mechanisms indicate that the method is suitable for wind tunnel flow seeding.

Mazumder, M. K.↗

Flow tracing fidelity of scattering aerosol in laser Doppler velocimetry

An experimental method for the determination of the flow-tracing fidelity of a scattering aerosol used in laser Doppler velocimeters was developed with particular reference to the subsonic turbulence measurements. The method employs the measurement of the dynamic response of a flow-seeding aerosol excited by acoustic waves. The amplitude and frequency of excitation were controlled in order to simulate the corresponding values of fluid turbulence components. Experimental results are presented on the dynamic response of aerosols over the size range from 0.1 to 2.0 microns in diam and over the frequency range 100 Hz to 100 kHz. It was observed that unit-density spherical scatterers with diameters of 0.2 micron followed subsonic air turbulence frequency components up to 100 kHz with 98% fidelity.

Mazumder, M. K.↗

Aerosol size spectrum analysis using relaxation time measurement

An experimental method has been developed to measure the dynamic relaxation times of aerosol particles. The particle relaxation time (tau-p) is determined from the ratio of the velocity amplitude of an aerosol particle (v-p) to the velocity amplitude of the medium (u-g) while the aerosol is subjected to acoustic excitation of a known frequency. A differential laser Doppler velocimeter is used to measure v-p, while a microphone is used to measure u-g. From the value of tau-p, the aerodynamic diameter of the particle can be determined if the particle density is known. The method can be applied to real-time in situ measurement of size distribution of an aerosol containing both solid particles and liquid droplets in the range of 0.1-10.0-micron diameters.

Kirsch, K. J.↗

Fluid dynamic studies on scattering aerosol and its generation for application as tracer particles in supersonic flow measurements utilizing laser Doppler velocimeter

An experimental study on the particle-fluid interactions of scattering aerosols was performed using monodisperse aerosols of different particle sizes for the application of laser Doppler velocimeters in subsonic turbulence measurements. Particle response was measured by subjecting the particles to an acoustically excited oscillatory fluid velocity field and by comparing the ratio of particle velocity amplitude to the fluid velocity amplitude as a function of particle size and the frequency of oscillation. Particle velocity was measured by using a differential laser Doppler velocimeter. The test aerosols were fairly monodisperse with a mean diameter that could be controlled over the size range from 0.1 to 1.0 micron. Experimental results on the generation of a fairly monodisperse aerosol of solid particles and liquid droplets and on the aerosol response in the frequency range 100 Hz to 100 kHz are presented. It is indicated that a unit density spherical scatterer of 0.3 micron-diameter would be an optimum choice as tracer particles for subsonic air turbulence measurements.

Mazumder, M. K.↗

Flow tracing fidelity of scattering aerosol in laser Doppler velocimetry

An experimental method for determinating the flow tracing fidelity of a scattering aerosol used in laser Doppler velocimeters was developed with particular reference to the subsonic turbulence measurements. The method employs the measurement of the dynamic response of a flow seeding aerosol excited by acoustic waves. The amplitude and frequency of excitation were controlled to simulate the corresponding values of fluid turbulence components. Experimental results are presented on the dynamic response of aerosols over the size range from 0.1 to 2.0 microns in diameter and over the frequency range 100 Hz to 100 kHz. It was observed that unit density spherical scatterers with diameters of 0.2 microns followed subsonic air turbulence frequency components up to 100 kHz with 98 percent fidelity.

Mazumder, M. K.↗

Generation and fluid dynamics of scattering aerosols in laser Doppler velocimetry

An experimental study on the particle-fluid interactions of scattering aerosols was performed using monodisperse aerosols of different particle sizes for the application of laser Doppler velocimeters in subsonic turbulence measurements. Particle response was measured by subjecting the particles to an acoustically excited flow field where the particle Reynolds numbers were controlled to simulate the corresponding values of fluid turbulence. The test aerosols were fairly monodisperse with a mean diameter that could be controlled over the size range from 0.1 to 1.0 micron. Experimental results on the generation of a fairly monodisperse aerosol of solid particles and liquid droplets and on the aerosol response in the frequency range 100 Hz to 100 kHz are presented. The present study indicates that a unit density spherical scatterer of 0.3 micron-diameter would be an optimum choice as tracer particles for subsonic air turbulence measurements.

Mazumder, M. K.↗