Search NASA⌕ Search

Engineering topics

Kiselev, V. V.

Publications and source records attributed to Kiselev, V. V..

Planar multifrequency mid-IR microwave-pumped lasers

The characteristics of planar repetitively pulsed diffusion-cooled HF, DF, HF – DF, Xe, and HF – DF – Xe(Kr) lasers pumped by a microwave discharge (2.45 GHz) are studied depending on the pump pulse duration (10 – 40 μs) and repletion rate (50 – 400 Hz), as well as on the composition and pressure of the working gas mixture (30 – 200 Torr) at low (to 0.6 L s{sup −1}) gas flow rates. It is demonstrated for the first time that a HF – DF – Xe gas-discharge laser may simultaneously operate as a HF – DF chemical molecular laser and a recombination laser based on xenon atom transitions and generate broadband (octave) radiation in the range 2.0 – 4.2 μm with an average output power of 43 mW and an efficiency of 0.9 %. With substitution of xenon for krypton, lasing in a HF – DF – Kr laser is obtained at wavelengths of 2.52 – 4.15 μm. Lasing in a HF – DF laser was achieved simultaneously in two spectral regions (2.7 – 2.9 and 3.6 – 4.2 μm) with an output power of ∼50 mW. It is found that a decrease in the pump pulse duration with a simultaneous increase in the pulse repletion rate for retaining the average energy deposition leads to an increase in the average output power and efficiency of the laser. At low pulse repetition rates (50 – 100 Hz) and a low gas mixture flow rate, helium buffer gas can be effectively substituted for neon. Operation of the Xe laser was achieved in the spectral range 2.03 – 3.65 μm with an average output power of 580 Mw at a pump pulse duration of 20 μs, a pulse repetition rate to 10 kHz, and a maximum efficiency of 55 %. The obtained experimental results demonstrate the possibility of creating broadband HF – DF – Xe lasers emitting in the frequency range 2 – 4 μm with a desired ratio of intensities in different spectral ranges. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Determination of dynamic corrections to point coordinates of photographs obtained by the Zond 6 and Zond 8 spacecraft

The linear and angular motions of the Zond 6 and Zond 8 spacecraft imaging camera during the exposure cause displacements of the optical image points. In the case of instantaneous exposure of each individual point and the nonsimultaneous exposure of the complete frame, this leads to finite geometric shifts of the points without causing blurring of the photographic image. Therefore, when measuring the resulting photographic pictures, the problem arises of reducing the picture point positions to a common instant of time. This reduction is performed by means of dynamic corrections to the measured picture point coordinates. These corrections are found by using formulas of dynamic photogrammetry. Their use with the Zond space probe photographs is described.

Kiselev, V. V.↗