Three-pole wigglers at NSLS-II

The National Synchrotron Light Source-II (NSLS-II) at Brookhaven National Lab (BNL) is a third-generation medium-energy storage ring with 3 GeV and sub-nm-rad horizontal emittance, equipped with a top-off capability of 500 mA. It is designed to deliver an extremely intense photon beam across a wide spectral range, from the far-infrared to the very hard X-ray region. This outstanding performance is achieved through a combination of bending magnets (BM), three-pole wigglers (3 PW), and advanced insertion device (ID) sources. Six three-pole wigglers have been constructed at the NSLS-II IDs Lab. These devices are used to produce broadband radiation with lower angular power density and to monitor the electron beam emittance and energy spread. Here, this paper describes the R&D activities focused on developing the required magnetic and mechanical designs, along with magnetic field optimization and the final magnetic measurement results. It also covers the spectral brightness, flux, power density, spatial and angular output properties of the 3 PWs, including their commissioning results and their effects on the performance of the NSLS-II storage ring.

36 MATERIALS SCIENCE↗

Measurements of High Coercitivity PrFeB magnets at the Louis Neel Laboratory

Magnetization curves of newly developed high coercivity PrFeB magnets have been measured at various temperatures down to 40K. The measurement was carried out at the Lous Néel Laboratory in Grenoble, France using its 11T superconducting magnetometer. It has been shown that no significant gain in performance can be achieved below 77K where one can expect 16% gain in the remanence compared to that at a room temperature.

43 PARTICLE ACCELERATORS↗

Spectrum-Based Alignment of In-Vacuum Undulators in a Low-Emittance Storage Ring

In-vacuum undulators (IVU) are used extensively at light source facilities, in particular at medium-energy storage rings, where these devices are the main sources of high-brightness hard X-rays. The relatively small vertical magnetic gaps that are used in these planar undulators make them rather sensitive to misalignments of magnet arrays with respect to the electron orbit in the vertical plane. Based on commissioning results of undulator-based hard X-ray beamlines at the National Synchrotron Light Source II (NSLS-II)—a Department of Energy Office of Science User Facility at Brookhaven National Laboratory— IVU misalignment was found to be the most frequent cause of spectral “underperformance.” It is possible, nevertheless, to restore the performance using a spectrum-based IVU alignment procedure described in this article.

47 OTHER INSTRUMENTATION↗

Development and operation of a Pr 2 Fe 14 B based cryogenic permanent magnet undulator for a high spatial resolution x-ray beam line

Short period, high field undulators are used to produce hard x-rays on synchrotron radiation based storage ring facilities of intermediate energy and enable short wavelength free electron laser. Cryogenic permanent magnet undulators take benefit from improved magnetic properties of RE 2 Fe 14 B (Rare Earth based magnets) at low temperatures for achieving short period, high magnetic field and high coercivity. Using Pr 2 Fe 14 B instead of Nd 2 Fe 14 B, which is generally employed for undulators, avoids the limitation caused by the spin reorientation transition phenomenon, and simplifies the cooling system by allowing the working temperature of the undulator to be directly at the liquid nitrogen one (77 K). We describe here the development of a full scale (2 m), 18 mm period Pr 2 Fe 14 B cryogenic permanent magnet undulator (U18). The design, construction and optimization, as well as magnetic measurements and shimming at low temperature are presented. In conclusion, the commissioning and operation of the undulator with the electron beam and spectrum measurement using the Nanoscopmium beamline at SOLEIL are also reported.

43 PARTICLE ACCELERATORS↗

Latest experiences and future plans on NSLS-II insertion devices

National Synchrotron Light Source-II (NSLS-II) is the latest storage ring of 3 GeV energy at the Brookhaven National Laboratory (BNL). The horizontal emittance of the electron beam with the currently installed six damping wigglers is 0.9 nm.rad, which could be further reduced to 0.5 nm.rad with more insertion devices (IDs). With only one RF cavity the beam current is restricted to 200 mA. Five hundred mA operation is envisaged for next year with an addition of the second cavity. Six (plus two branches) beamlines have been commissioned in the initial phase of the project. In July 2015, three NIH funded beamlines called “Advanced Beamlines for Biological Investigations with X-rays” (ABBIX) will be added for operation. This paper describes the experiences of ID development, installation, and commissioning for the NSLS-II project as well as our future plans to improve the performance of the facility in terms of source development.

43 PARTICLE ACCELERATORS↗

Magnet system optimization for segmented adaptive-gap in-vacuum undulator

Segmented Adaptive Gap in-vacuum Undulator (SAGU), in which different segments have different gaps and periods, promises a considerable spectral performance gain over a conventional undulator with uniform gap and period. According to calculations, this gain can be comparable to the gain achievable with a superior undulator technology (e.g. a room-temperature in-vacuum hybrid SAGU would perform as a cryo-cooled hybrid in-vacuum undulator with uniform gap and period). However, for reaching the high spectral performance, SAGU magnetic design has to include compensation of kicks experienced by the electron beam at segment junctions because of different deflection parameter values in the segments. Here we show that such compensation to large extent can be accomplished by using a passive correction, however, simple correction coils are nevertheless required as well to reach perfect compensation over a whole SAGU tuning range. Magnetic optimizations performed with Radia code, and the resulting undulator radiation spectra calculated using SRW code, demonstrating a possibility of nearly perfect correction, are presented.

47 OTHER INSTRUMENTATION↗

NSLS-II storage ring insertion device and front-end commissioning and operation

The National Synchrotron Light Source II (NSLS-II) is a state of the art 3 GeV third generation light source at Brookhaven National Laboratory. During spring/ summer of 2014, the storage ring was commissioned up to 50 mA without insertion devices. In the fall of 2014, we began commissioning of the project beamlines, which included seven insertion devices on six ID ports. Beamlines IXS, HXN, CSX-1, CSX-2, CHX, SRX, and XPD-1 consist of elliptically polarized undulator (EPU), damping wigglers (DW) and in-vacuum undulators (IVU) covering from VUV to hard x-ray range. In this paper, experience with commissioning and operation is discussed. We focus on reaching storage ring performance with IDs, including injection, design emittance, compensation of orbit distortions caused by ID residual field, source point stability, beam alignment and tools for control, monitoring and protection of the ring chambers from ID radiation.