Search NASASearch

Engineering topics

Kittel, P.

Publications and source records attributed to Kittel, P..

At least 19 records

NASA Space Cryocooler Programs: A 2003 Overview

Mechanical cryocoolers represent a significant enabling technology for NASA's Earth and Space Science missions. An overview is presented of ongoing cryocooler activities within NASA in support of current flight projects, near-term flight instruments, and long-term technology development. NASA programs in Earth and space science observe a wide range of phenomena, from crop dynamics to stellar birth. Many of the instruments require cryogenic refrigeration to improve dynamic range, extend wavelength coverage, and enable the use of advanced detectors. Although, the largest utilization of coolers over the last decade has been for instruments operating at medium to high cryogenic temperatures (55 to 150 K), reflecting the relative maturity of the technology at these temperatures, important new developments are now focusing at the lower temperature range from 4 to 20 K in support of studies of the origin of the universe and the search for planets around distant stars. NASA's development of a 20K cryocooler for the European Planck spacecraft and its new Advanced Cryocooler Technology Development Program (ACTDP) for 6-18 K coolers are examples of the thrust to provide low temperature cooling for this class of missions.

Ross, R. G., Jr.

Simple Two-Dimensional Corrections for One-Dimensional Pulse Tube Models

One-dimensional oscillating flow models are very useful for designing pulse tubes. They are simple to use, not computationally intensive, and the physical relationship between temperature, pressure and mass flow are easy to understand when used in conjunction with phasor diagrams. They do not possess, however, the ability to directly calculate thermal and momentum diffusion in the direction transverse to the oscillating flow. To account for transverse effects, lumped parameter corrections, which are obtained though experiment, must be used. Or two-dimensional solutions of the differential fluid equations must be obtained. A linear two-dimensional solution to the fluid equations has been obtained. The solution provides lumped parameter corrections for one-dimensional models. The model accounts for heat transfer and shear flow between the gas and the tube. The complex Nusselt number and complex shear wall are useful in describing these corrections, with phase relations and amplitudes scaled with the Prandtl and Valensi numbers. The calculated ratio, a, between a two-dimensional solution of the oscillating temperature and velocity and a one-dimensional solution for the same shows a scales linearly with Va for Va less than 30. In this region alpha less than 0.5, that is, the enthalpy flow calculated with a two-dimensional model is 50% of a calculation using a one-dimensional model. For Va greater than 250, alpha = 0.8, showing that diffusion is still important even when it is confined to a thing layer near the tube wall.

Lee, J. M.

NASA space cryocooler programs -- a 2003 overview

Mechanical cryocoolers represent a significant enabling technology for NASA's Earth and Space Science Missions. An overview is presented of ongoing cryocooler activities within NASA in support of current flight projects, near-term instruments, and long-term technology development.

cryocoolers

Zero Boil Off Cryogen Storage for Future Launchers

Zero boil off (ZBO) cryogen storage using both cryocoolers and passive insulation technologies will enable long-term exploration missions by allowing designers to optimize tankage without the need for excess cryogen storage to account for boil off. Studies of ZBO (zero boil off) have been on-going in the USA for several years. More recently, a review of the needs of advanced space propulsion took place in Europe. This showed the interest of the European community in cryogenic propulsion for planetary missions as well as the use of liquid hydrogen for large power electric propulsion (manned Mars missions). Although natural boiling could be acceptable for single leg missions, passive insulation techniques yield roughly a I% per month cryogen loss and this would not be cost effective for robotic planetary missions involving storage times greater than one year. To make economic sense, long-term exploration missions require lower tank capacity and longer storage times. Recent advances in cryocooler technology, resulting in vast improvements in both cooler efficiency and reliability, make ZBO is a clear choice for planetary exploration missions. Other, more near term applications of ZBO include boil-off reduction or elimination applied to first and upper stages of future earth-to-orbit (ETO) launchers. This would extend launch windows and reduce infrastructure costs. Successors to vehicles like Ariane 5 could greatly benefit by implementing ZBO. Zero Boil Off will only be successful in ETO launcher applications if it makes economic sense to implement. The energy cost is only a fraction of the total cost of buying liquid cryogen, the rest being transportation and other overhead. Because of this, higher boiling point cryogens will benefit more from on-board liquefaction, thus reducing the infrastructure costs. Since hydrogen requires a liquefier with at least a 17% efficiency just to break even from a cost standpoint, one approach for implementing ZBO in upper stages would be to actively cool the shield in the hydrogen tank to reduce the parasitic losses. This would allow the use of less expensive, presently available coolers (80 K vs. 20 K) and potentially simplify the system by requiring only a single compressor on the pad amd a single disconnect line. The compressor could be a hefty commercial unit, with only the cold head requiring expensive flight development and qualification. While this is actually a reduced boil off configuration rather than a zero-boil off case, if the cryogen loss could be cut significantly, the increase in hold time and reduced need for draining and refilling the propellant tanks could meet the vehicle operations needs in the majority of instances.Bearing in mind the potential benefits of ZBO, NASA AMES and SNECMA Moteurs decided to exchange their technical views on the subject. This paper will present a preliminary analysis for a multi-mission module using a fairly low thrust cryogenic engine and ZBO during cruise. Initial mass is 5.5. tons (in ETO). The cryogenic engine will be used near each periapsis in order to minimize the AV requirement. The payload obtained by this propulsion system is compared to a classical storable bipropellant propulsion system for several cases (e. g. Mars lander, Jupiter orbiter, Saturn orbiter). For the Jupiter and Saturn cases, the power source could be an RTG or a large parabolic mirror illuminating a solar panel. It is shown -that - due to its much larger specific impulse - the cryogenic ZBO solution provides much higher payloads, especially for exploration missions involving landing on planets, asteroids, comets, or other celestial bodies.

Valentian, D.

An Overview of NASA Efforts on Zero Boiloff Storage of Cryogenic Propellants

Future mission planning within NASA has increasingly motivated consideration of cryogenic propellant storage durations on the order of years as opposed to a few weeks or months. Furthermore, the advancement of cryocooler and passive insulation technologies in recent years has substantially improved the prospects for zero boiloff storage of cryogenics. Accordingly, a cooperative effort by NASA's Ames Research Center (ARC), Glenn Research Center (GRC), and Marshall Space Flight Center (MSFC) has been implemented to develop and demonstrate "zero boiloff" concepts for in-space storage of cryogenic propellants, particularly liquid hydrogen and oxygen. ARC is leading the development of flight-type cryocoolers, GRC the subsystem development and small scale testing, and MSFC the large scale and integrated system level testing. Thermal and fluid modeling involves a combined effort by the three Centers. Recent accomplishments include: 1) development of "zero boiloff" analytical modeling techniques for sizing the storage tankage, passive insulation, cryocooler, power source mass, and radiators; 2) an early subscale demonstration with liquid hydrogen 3) procurement of a flight-type 10 watt, 95 K pulse tube cryocooler for liquid oxygen storage and 4) assembly of a large-scale test article for an early demonstration of the integrated operation of passive insulation, destratification/pressure control, and cryocooler (commercial unit) subsystems to achieve zero boiloff storage of liquid hydrogen. Near term plans include the large-scale integrated system demonstration testing this summer, subsystem testing of the flight-type pulse-tube cryocooler with liquid nitrogen (oxygen simulant), and continued development of a flight-type liquid hydrogen pulse tube cryocooler.

Hastings, Leon J.

Performance Testing of a Lightweight, High Efficiency 95 K Cryocooler

Performance data are presented for a flight-like, lightweight, high efficiency pulse tube cryogenic cooler. The cooler has a mass of less than 4.0 kg, and an efficiency of 12 W/W, which is 18% of Carnot at 95 K, nearly double the efficiency of previous cooler designs, The mass of the cooler has been reduced by approximately a factor of three. The design point cooling power is 10 watts at 95 K at a heat rejection temperature of 300 K. The no-load temperature is 45 K. The compressor is built by Hymatic Engineering, UK, and is of a horizontally opposed piston design using flexure bearings. The vertical pulse tube is built by TRW with the heat exchanger or cold block located approximately mid-way along the tube. The final assembly and integration is also performed by TRW. The inertance tube and dead volume are contained within one of the compressor end caps. The cooler was developed by TRW under a joint NASA-DOD program, and has a goal of 10 yr operating lifetime. Potential NASA applications will focus on using coolers of this type in Zero boil off (ZBO) cryogen storage topologies for next generation launch vehicles. Zero boil off systems will feature significant reductions in tank size and Initial Mass to Low Earth Orbit (IMLEO), thereby significantly reducing the cost of access to space, and enabling future missions. The coolers can be used directly in liquid oxygen (LOx) or liquid methane ZBO systems, as shield coolers in liquid hydrogen tanks, or as first stage coolers in two-stage liquid hydrogen (LH2) ZBO cooler systems. Finally, the coolers could find applications in exploration missions where either propellants or breathable oxygen are extracted from the planetary atmosphere using a Sabatier or similar process. The gases could then be liquefied for storage either directly in return vehicle propellant tanks or on the planetary surface. Data presented were taken with the cooler operating in a vacuum of 10 (exp -5) torr, at controlled rejection temperatures from 300 K down to 275 K using a cold water heat exchanger bolted to the cooler. Heat loads were varied between 0.5 W and 15 W by supplying current to a 50 omega resistor mounted on a copper cold plate which was bolted to the cooler cold block. Silicon diodes mounted on both the cold plate and the heat exchanger provided accurate temperature measurement to within plus or minus 0.25 K and plus or minus 0.5 K respectively, up to 100 K with plus or minus 1% accuracy above 100 K. Input power to the compressor was limited to 180 W, corresponding to a maximum stroke of 80%.

Salerno, Lou

Terrestrial Applications of Zero Boil-Off Cryogen Storage

Storing cryogenic propellants with zero boil off (ZBO) using a combination of active (cryocoolers) and passive technologies has recently received a great deal of attention for applications such as future long-term space missions. This paper will examine a variety of potential near-term terrestrial applications for ZBO and, where appropriate, provide a rough order of magnitude cost benefit of implementing ZBO technology. NASA's Space Shuttle power system uses supercritical propellant tanks, which are filled several days before launch. If the launch does not occur within 48-96 hours, the tanks must be drained and refilled, further delaying the launch. By implementing ZBO, boil off could be eliminated and pad hold time extended. At the launch site, vented liquid hydrogen (LH2) storage dewars lose 1200-1600 gal/day through boiloff. Implementing ZBO would eliminate this, saving $300,000-$400,000 per year. Similarly, overland trucking of LH2 from the supplier to the launch site via roadable dewars results in a cryogen loss of ten percent per tanker (1500 gal/tanker). Providing a cryocooler on board the rig would prevent this loss. Previous work investigating variable density insulation found that a 50% reduction in evaporation from a 6000 gallon dewar would save $5000 per year. For a 20 year dewar lifetime, the payback period would be less than two years. Similar benefits could be realized at other storage facilities across the nation. Within the superconductivity community, there is skepticism about using coolers, based upon reliability concerns. By providing a cooler on the dewar, lifetime could be extended while retaining fail-safe capability. If the cooler failed, it would merely lower the storage life of the dewar.

Salerno, L. J.

A Liquefier for Mars Surface Propellant Production

NASA's planned Mars exploration missions will require that cryogenic propellants be manufactured on the surface. The present scenario calls for oxygen and methane gases to he produced using the carbon dioxide atmosphere plus seed hydrogen brought from Earth. Gases will require liquefaction for both storage on the Martian surface and for use in the ascent vehicle. The planned liquefaction rates range from 12.6 g/hr of oxygen for the 2003 robotic mission to 2500 g/hr for the later human missions. This paper presents the results of a nitrogen liquefaction demonstration using a commercially available cryocooler. The experiment was set up to liquefy nitrogen gas instead of oxygen to limit laboratory safety concerns. A nitrogen gas condensor, attached to the cooler's cold tip, was sized to liquefy up to 42 gN2/hr at the intended storage pressure (0.2 MPa). The experiment was conducted inside an atmospheric, air-filled, refrigerated chamber simulating the average Martian daytime temperature (240 K). In this demonstration a liquefaction rate of 9.1 gN2/hr was realized, which is equivalent to 13 gO2/hr.

Salerno, Lou J.

Useful Scaling Parameters for the Pulse Tube

A set of eight non-dimensional scaling parameters for use in evaluating the performance of Pulse Tube Refrigerators is presented. The parameters result after scaling the mass, momentum and energy conservation equations for an axisymmetric, two-dimensional system. The physical interpretation of the parameters are described, and their usefulness is outlined for the enthalpy flow tube (open tube of the pulse tube). The scaling parameters allow the experimentalist to characterize three types of transport: enthalpy flow, mass streaming and heat transfer between the gas and the tube. Also reported are the results from a flow visualization experiment in which steady mass streaming in compressible oscillating flow is observed.

Lee, J. M.

An Orifice Pulse Tube Cooler for CMOS Computer Cooling

The subject orifice pulse tube cooler employs dual opposed compressor pistons, clearance seals, moving coil linear motors, and flexible bearings cooling capacity is 100 watts at 200 K. A matrix of optimizations explored load temperatures and cooling capacities of 50 K, 100 K, 200 K, 1 watt, 10 watts, and 100 watts. The optimization process resulted in a design with zero second entrance flow and a non-resonant pulse tube. Topics include performance results, mechanical design, and development problems and solutions. The development seeks to use orifice pulse tube mechanical simplicity to achieve a computer cooler with acceptable efficiency, low materials cost, low labor cost, long life, high reliability, low vibration, operation at the standard 60 Hz U.S. grid frequency, and control through simple drive and control electronics.

Riggle, P.

Efficiency Calculations For a Magnetic Refrigerator Operating Between 2K and 10K

An adiabatic demagnetization refrigerator (ADR) is being developed at NASA-Ames Research Center. The ADR will operate between 2 K and 10 K and will provide 50 mW of cooling at 2 K. The refrigerant in the ADR is Gadolinium Gallium Garnet (GGG). Absorption of heat at 2 K and heat rejection at 10 K in this fully static refrigerator is made possible by the incorporation of 2 K and 10 K heat switches. Physical layout and experimental results are presented in a parallel paper. The present paper discusses the thermal losses associated with components of the ADR as they occur in various parts of the refrigeration cycle. The results are summarized in terms of a prediction for the ADR efficiency.

Helvensteijn, Ben P. M.

Steady Secondary Momentum and Enthalpy Streaming in the Pulse Tube Refrigerator

Our study investigates the steady secondary streaming that occurs in the pulse tube refrigerator through application of the conservation laws and support by flow visualization experiments. A series expansion of the mass, momentum and energy conservation laws for an axisymmetric system yields a set of linear differential equations. The series solution is expanded in the small parameter epsilon = 1/Str where Str is the Strouhal number. The O(1) basic flow problem is solved for the case of a compressible ideal gas oscillating within a cylindrical tube. The phase and amplitude of the boundary conditions on axial velocity are treated as independent parameters. The basic solution for the gas domain is solved for the case of temperature and heat flux coupling to the tube wall. The temperature coupled solution shows how the Fourier number of the tube wall affects the gas temperature, phase angle, and time-averaged enthalpy flow. The basic solution is also examined for the time-averaged Reynolds stresses which are shown to be the driving force that produces steady secondary momentum streaming. Calculated solutions to the steady momentum streaming are shown to be in qualitative agreement with flow visualization experiments.

Lee, J. M.

Thermal Conductances Of Cold Metal Contacts Below 6 K

Conductances vary with temperature according to simple power law. Report presents data on thermal conductances of pure aluminum and stainless-steel 304 contact pairs. Data cover contacts with surface finishes of 0.1- to 1.6-micrometer root-mean-square roughness at temperatures from 1.6 to 6.0 K, under applied contact forces up to 670 N. Such data needed for optimal design of bolted joints in cryogenic instruments, particularly infrared instruments and focal-plane sensors.

Salerno, L. J.

Thermal conductance of augmented pressed metallic contacts at liquid helium temperatures

The thermal conductance of uncoated oxygen-free high conductivity (OFHC) copper, 6061-T6 aluminum, free-machining brass, and 304 stainless steel sample pairs which were augmented with a gold coated 6061-T6 aluminum washer inserted between the contact surfaces was measured over the temperature range of 1.6 to 6.0 K, with applied forces from 22 to 670 N. The contact surfaces of the sample pairs were prepared with a 0.8 micron lapped finish, while the finish of the aluminum washer was 0.2 micron lapped. The contribution to the overall thermal impedance by the bulk conductance of the aluminum washer was negligible. It was found that addition of the washer offered no significant conductance improvement over an uncoated single contact pair; any benefits from using the gold plated washer were counteracted by the addition of two more contact surfaces. Additionally, the thermal conductance of a 'combination' aluminum sample pair having one gold coated and one uncoated surface was measured and compared to the washer pair. The ratio of the conductance of the washer pair to half the conductance of the 'combination' pair was found to be constant and near unity over the temperature range of the data obtained, within experimental error.

Salerno, L. J.

Ideal orifice pulse tube refrigerator performance

The recent development of orifice pulse tube refrigerators has raised questions as to what limits their ultimate performance. Using an analogy to the Stirling cycle refrigerator, the efficiency (cooling power per unit input power) of an ideal orifice pulse tube refrigerator is shown to be T1/T0, the ratio of the cold temperature to the hot temperature.

Kittel, P.

Report of the sensor cooler technology panel

The Sensor Cooler Technology Panel identified three major areas in which technology development must be supported in order to meet the system performance requirements for the Astrotech 21 mission set science objectives. They are: long life vibration free refrigerators; mechanical refrigeration for 2 K to 5 K; and flight testing of emerging prototype refrigerators. A development strategy and schedule were recommended for each of the three areas.

Ross, Ronald

Salt materials testing for a spacecraft adiabatic demagnetization refrigerator

As part of a technology development effort to qualify adiabatic demagnetization refrigerators for use in a NASA spacecraft, such as the Space Infrared Telescope Facility, a study of low temperature characteristics, heat capacity and resistance to dehydration was conducted for different salt materials. This report includes results of testing with cerrous metaphosphate, several synthetic rubies, and chromic potassium alum (CPA). Preliminary results show that CPA may be suitable for long-term spacecraft use, provided that the salt is property encapsulated. Methods of salt pill construction and testing for all materials are discussed, as well as reliability tests. Also, the temperature regulation scheme and the test cryostat design are briefly discussed.

Savage, M. L.