Search NASA⌕ Search

Engineering topics

Kleedtke, Noah A.

Publications and source records attributed to Kleedtke, Noah A..

Hybrid Particle Swarm-Interpolation Algorithm for Improved Critical Experiment Design

The typical goal of designing a critical experiment is twofold: a system that is both critical and optimized for some other value. This value could be an energy-integrated sensitivity, percent fissions in a certain energy range, or some other value that can be calculated by a transport code. By simulating different combinations of reflector, moderator, and fuel thicknesses a designer can identify such a desirable configuration. The domain of all possible combinations of these thicknesses is referred to as the experiment search space. As more dimensions are added, the search space increases in size exponentially. For a three-dimensional case, which includes three thickness values between zero and ten centimeters to the nearest tenth of a millimeter, a total of 1,000 3 , configurations exists. Rather than check each configuration individually, which would be extremely computationally expensive, it has been shown to be more efficient to use a conventional particle swarm optimization (PSO) algorithm to identify critical and optimal configurations. This work presents the theory and implementation of a novel hybrid PSO interpolation algorithm to perform these optimizations faster than a conventional PSO algorithm. To demonstrate this, an example optimization will be carried out by the conventional and hybrid PSO algorithms and their performances will be compared.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Sensitivity Coefficients Calculated for the Prompt Neutron Decay Constant At or Near Delayed Critical

The derivation of a non-invasive prompt neutron decay constant sensitivity coefficient is provided in this work. The computation of the sensitivity coefficient derived in this work does not require modification of Monte Carlo source code and is based on capabilities available in Monte Carlo N-Particle R© Code Version 6.2. The prompt neutron decay constant sensitivity coefficients are calculated for 44-group and 252-group energy structures for specific nuclide-reaction pairs in the Jezebel benchmark experiment. The nuclide-reaction pairs investigated in this work include Pu- 239(n,f), Pu-240(n,f), and Pu-241(n,f). Physical explanations of the sensitivity profiles exhibited by the 252-group energy structure are investigated for the prompt neutron multiplication factor, mean neutron lifetime, and prompt neutron decay constant. The prompt neutron decay constant sensitivity coefficients calculated for the 44-group and 252-group energy structure of Pu-239(n,f) are compared. Lastly, the 44-group energy structure sensitivity coefficients calculated are used for nuclear-data induced uncertainty quantification of the neutron multiplication factor. This work shows that a reduction in the nuclear data-induced uncertainty of the neutron multiplication factor is possible for all nuclide-reaction pairs investigated when prompt neutron decay constant sensitivity coefficients are utilized. This is important for new critical experiment design optimization studies of measurement configurations. This work provides a basis for more detailed sensitivity analysis and uncertainty quantification of nuclide, reaction, and energy-specific cross section data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Sensitivity Coefficients Calculated for the Prompt Neutron Decay Constant at or Near Delayed Critical [Abstract]

Experimenters at Los Alamos National Laboratory (LANL) measure the prompt neutron decay constant for many experiments at the National Criticality Experiments Research Center (NCERC) to infer reactivity and the effective neutron multiplication factor. These quantities are very important for nuclear criticality safety and validating nuclear data. Uncertainty in measures of criticality of an experimental configuration can be determined prior to physically performing the experiment by applying first order perturbation theory to Monte Carlo codes, such as MCNP®. The first order perturbation theory produces first derivatives of some nuclear parameter to nuclear data (e.g., cross section data). This first derivative is commonly referred to as a sensitivity coefficient. Currently, the MCNP® software has the capability of computing effective neutron multiplication factor sensitivity coefficients to cross section data. This work builds off of this MCNP® capability and the first order perturbation theory to provide a method of calculating sensitivity coefficients for the prompt neutron decay constant at or near delayed critical to cross section data. The prompt neutron decay constant sensitivity coefficient calculated in this work does not depend on any modification of the MCNP® source code. Prompt neutron decay constant sensitivity coefficient calculations can be used to infer reactivity and effective neutron multiplication factor sensitivity coefficient values as well. By investigating the trends of prompt neutron decay constant sensitivity coefficients for nuclide-reaction pairs across energy spectra, experiments can be designed to maximize or minimize the uncertainty in the prompt neutron decay constant in a particular energy region, which can lead to further optimization studies. Prompt neutron decay constant sensitivity coefficients will be calculated for the Jezebel benchmark. Subsequently, these sensitivity coefficients will be used in a data assimilation process to determine if there is or are optimal experiments that can be performed to provide insight into adjustments of uncertain/inaccurate cross section data. Specifically, the effect of the prompt neutron decay constant sensitivity coefficients on the nuclear data-induced uncertainty in the effective neutron multiplication factor will be examined

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The CWS Experiments – An Experimental Study of the Effects of Chlorine on Thermal Neutron Absorption

The Chlorine Worth Study (CWS) experiments consist of layers of Zero Power Physics Reactor plates moderated by high density polyethylene, polyvinyl chloride, and chlorinated polyvinyl chloride with the goal to produce a thermal critical experiment. A thick high density polyethylene reflector surrounds the experiments. Aluminum fuel trays and frames were used to conduct the intrinsic heat generation of the plutonium plates away from the core and out to the top plate and the platen, both acting as heat sinks. The goal of the CWS experiments was to provide benchmark critical experiments that were sensitive to chlorine and matched the sensitivity of criticality safety applications for aqueous chloride operations at PF-4 at Los Alamos National Laboratory. The specific aqueous chloride PF-4 applications were solutions of 30 g/L plutonium, 300 g/L plutonium, and 600 g/L plutonium. The CWS experiments were designed using prototype methods developed by the ARCHIMEDES and EUCLID projects at Los Alamos National Laboratory. The CWS experiments were performed in December of 2021 at the National Criticality Experiments Research Center at the Nevada Nuclear Security Site on the Planet critical assembly. It is intended that the CWS experiments will be evaluated and submitted to the ICSBEP in the future as criticality safety benchmarks.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Particle Swarm Optimization Algorithm for Critical Experiment Design

Nuclear criticality experiments are used to validate nuclear cross section data used by simulation software. This is typically achieved by designing a critical system with a high sensitivity to a certain material’s cross section. Once the experiment has been carried out, a high fidelity model of the system is developed into a benchmark. When this benchmark model is simulated by a transport code, some of the difference between the experimental and computational effective neutron multiplication factor can be attributed to inaccurate nuclear data. Nuclear data evaluators then can make adjustments accordingly to improve cross section data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Sensitivity Studies, Gap Analysis, and Benchmark Experiment Optimization for Reactor Physics and Criticality Safety Applications

Many new reactor designs, such as advanced reactors and micro reactors, have materials that lack nuclear data validation. This is also true for many other applications in criticality safety and global security. Both differential and integral experiments are needed to validate cross-section data. Without this, a user cannot have confidence in the predicted results of a radiation-transport code. This work describes an approach called ARCHIMEDES (Application Relevant Critical/Subcritical HEU/Pu-based Integral Measurements for Enhancing Data and Evaluating Sensitivities) to design new criticality experiments that have similar k eff cross-section sensitivities to an application of interest. This process involves simulations to generate cross-section sensitivities to a parameter of interest (such as k eff ), a gap analysis to determine which existing benchmarks are most similar to the application, and an experiment optimization. Recently, there has been a great deal of interest in the reactor physics community on advanced reactors, micro reactors, and accelerator driven systems (ADS). This work will apply the described method to specific examples in this area. The focus of this work will be on the sensitivity study and gap analysis, while future work will include experiment design.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Gaussian Process Optimization of Sensitivity-Based Similarity Metrics between New Nuclear Applications and New/Existing Benchmarks

Confidently designing safe, new nuclear criticality experiments requires expert judgement, which could take years of experience. Sensitivity/uncertainty (S/U) analysis can be utilized by less experienced individuals to conservatively estimate uncertainties in important parameters, such as k eff , in newly proposed nuclear applications. This type of analysis relies on matching new nuclear applications with existing benchmark experiments. The Whisper-1.1 software package included in MCNP6.2 ®1 contains more than 1,100 International Criticality Safety Benchmark Evaluation Project (ICSBEP) benchmarks. These benchmarks however rarely match new nuclear applications. The number of benchmarks available to match a given set of materials or geometric configurations varies significantly. Furthermore, recently performed benchmark experiments may not have had enough time to be properly documented and published. Benchmarks are vital for determining the accuracy of nuclear data and can assist nuclear physics and evaluators in improving nuclear data libraries. Exhaustively exploring the parameter space using simulations with software such as MCNP is too computationally expensive. In this work, Gaussian process optimization was implemented to reduce the number of simulations needed for optimization over multiple parameters. This optimization scheme was designed to selectively generate new benchmarks with high sensitivity-based similarity metrics to user-defined nuclear applications. Two benchmark models of spherically nested shells containing plutonium, uranium, tantalum, and water were used in the optimization to match an application containing plutonium plates, stacked in a tantalum reflector, surrounded by water.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗