Search NASA⌕ Search

Engineering topics

Klein, A. L.

Publications and source records attributed to Klein, A. L..

Efficacy of anticoagulation in resolving left atrial and left atrial appendage thrombi: A transesophageal echocardiographic study

BACKGROUND: Transesophageal echocardiography (TEE) is the gold standard for evaluation of the left atrium and the left atrial appendage (LAA) for the presence of thrombi. Anticoagulation is conventionally used for patients with atrial fibrillation to prevent embolization of atrial thrombi. The mechanism of benefit and effectiveness of thrombi resolution with anticoagulation is not well defined. METHODS AND RESULTS: We used a TEE database of 9058 consecutive studies performed between January 1996 and November 1998 to identify all patients with thrombi reported in the left atrium and/or LAA. One hundred seventy-four patients with thrombi in the left atrial cavity (LAC) and LAA were identified (1.9% of transesophageal studies performed). The incidence of LAA thrombi was 6.6 times higher than LAC thrombi (151 vs 23, respectively). Almost all LAC thrombi were visualized on transthoracic echocardiography (90.5%). Mitral valve pathology was associated with LAC location of thrombi (P <.0001), whereas atrial fibrillation or flutter was present in most patients with LAA location of thrombi. Anticoagulation of 47 +/- 18 days was associated with thrombus resolution in 80.1% of the patients on follow-up TEE. Further anticoagulation resulted in limited additional benefit. CONCLUSIONS: LAC thrombi are rare and are usually associated with mitral valve pathology. Transthoracic echocardiography is effective in identifying these thrombi. LAA thrombi occur predominantly in patients with atrial fibrillation or flutter. Short-term anticoagulation achieves a high rate of resolution of LAA and LAC thrombi but does not obviate the need for follow-up TEE.

NASA Discipline Cardiopulmonary↗

Internet-based transfer of cardiac ultrasound images

A drawback to large-scale multicentre studies is the time required for the centralized evaluation of diagnostic images. We evaluated the feasibility of digital transfer of echocardiographic images to a central laboratory for rapid and accurate interpretation. Ten patients undergoing trans-oesophageal echocardiographic scanning at three sites had representative single images and multiframe loops stored digitally. The images were analysed in the ordinary way. All images were then transferred via the Internet to a central laboratory and reanalysed by a different observer. The file sizes were 1.5-72 MByte and the transfer rates achieved were 0.6-4.8 Mbit/min. Quantitative measurements were similar between most on-site and central laboratory measurements (all P > 0.25), although measurements differed for left atrial width and pulmonary venous systolic velocities (both P < 0.05). Digital transfer of echocardiographic images and data to a central laboratory may be useful for multicentre trials.

NASA Discipline Cardiopulmonary↗

Assessment of diastolic function by tissue Doppler echocardiography: comparison with standard transmitral and pulmonary venous flow

The objective of this study was to determine the utility of Doppler tissue echocardiography in the evaluation of diastolic filling and in discriminating between normal subjects and those with various stages of diastolic dysfunction. We measured myocardial velocities in 51 patients with various stages of diastolic dysfunction and in 27 normal volunteers. The discriminating power of each of the standard Doppler indexes of left ventricular filling, pulmonary venous flow, and myocardial velocities was determined with the use of Spearman rank correlation and analysis of variance F statistics. Early diastolic myocardial velocity (E(m)) was higher in normal subjects (16.0 +/- 3.8 cm/s) than in patients with either delayed relaxation (n = 15, 7.5 +/- 2.2 cm/s), pseudonormal filling (n = 26, 7.6 +/- 2.3 cm/s), or restrictive filling (n = 10, 7.4 +/- 2.4 cm/s, P <.0001). E(m ) was the best single discriminator between control subjects and patients with diastolic dysfunction (P =.7, F = 64.5). Myocardial velocities assessed by Doppler tissue echocardiography are useful in differentiating patients with normal from those with abnormal diastolic function. Myocardial velocity remains reduced even in those stages of diastolic dysfunction characterized by increased preload compensation.

NASA Discipline Regulatory Physiology↗

New Doppler echocardiographic applications for the study of diastolic function

Doppler echocardiography is one of the most useful clinical tools for the assessment of left ventricular (LV) diastolic function. Doppler indices of LV filling and pulmonary venous (PV) flow are used not only for diagnostic purposes but also for establishing prognosis and evaluating the effect of therapeutic interventions. The utility of these indices is limited, however, by the confounding effects of different physiologic variables such as LV relaxation, compliance and filling pressure. Since alterations in these variables result in changes in Doppler indices of opposite direction, it is often difficult to determine the status of a given variable when a specific Doppler filling pattern is observed. Recently, color M-mode and tissue Doppler have provided useful insights in the study of diastolic function. These new Doppler applications have been shown to provide an accurate estimate of LV relaxation and appear to be relatively insensitive to the effects of preload compensation. This review will focus on the complementary role of color M-mode and tissue Doppler echocardiography and traditional Doppler indices of LV filling and PV flow in the assessment of diastolic function.

NASA Discipline Cardiopulmonary↗