Search NASA⌕ Search

Engineering topics

Klein, J. E.

Publications and source records attributed to Klein, J. E..

Hydride Bed Helium-3 Recovery and Partial Regeneration

Savannah River Tritium Enterprise has used LaNi 4.25 Al 0.75 (LANA75) hydride beds to store hydrogen isotopes for over two decades. A benefit of using LANA75 is that the 3He generated from tritium decay is retained in the hydride material, allowing the hydride beds to deliver high-purity product gas. A disadvantage is that the 3He accumulates in the LANA75 material over time, which forms a heel that cannot be removed under normal operating conditions. The heel traps hydrogen in the bed, slowly reducing the operational capacity of the bed as the heel grows. Eventually, the 3 He begins to release from the material, preventing the delivery of high-purity product. The hydride beds are replaced when (1) operational capacity is reduced such that it is impactive to routine operations, and/or (2) product purity is not maintained due to 3 He release.Several beds were operated beyond their design life. One of these beds was selected to undergo heating beyond its normal operating temperature to evaluate the possibility of removing a portion of the hydrogen and helium heel to improve bed function until a replacement could take place. This bake-out removed a portion of the hydrogen and helium heel, and preliminary data indicate that bake-outs may partially regenerate the beds. The bed’s performance will continue to be monitored, and additional bake-outs will likely be performed. Performing bake-outs results in increasing the recovery of 3 He, more efficient end-of-life activities (such as isotopic exchange), and extension of the useful service life of the bed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Metal Bellows Valve Reliability Testing - Copper Stem Tip Testing

SRNL was funded in Mid-Year FY20 by NNSA NA-231 to continue evaluation of alternate valves for use in tritium service to support domestic Mo-99 production. The focus of the effort was to identify valve cycle life as a function of actuator size and stem tip material. Using the minimum size actuator to reliability open and close valves can reduce glovebox size and thus support domestic companies to “come to market” faster in supplying Mo-99 to the US market. This report serves as a continuation to the FY19 report and summarizes the task activities completed in FY20 after authorization to start work was obtained on May 5 th , 2020. Copper stem tips were tested on the Swagelok 1C and 5C actuated metal bellows valves. With ambitions to cycle each set 150,000 times, both 1C and 5C valves were met with high failure rates. The smaller 1C actuated valves required additional closing pressure to form a seal with the Cu stem tips installed however, excessive stem tip deformation may be the root cause of the majority of the valves failing before 500 cycles. The larger 5C actuated valves were cycled 150,000 times but still resulted in 80% failure rate, suspected of metal fatigue in the bellows due to high cycling frequencies.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗