Search NASA⌕ Search

Engineering topics

Klein, M

Publications and source records attributed to Klein, M.

Plans for an ERL Test Facility at CERN

The baseline electron accelerator for LHeC and one option for FCC-he is an Energy Recovery Linac. To prepare and study the necessary key technologies, CERNhas started – in collaboration with JLAB and Mainz University – the conceptual design of an ERL Test Facility (ERL-TF). Staged construction will allow the study under different conditions with up to 3 passes, beam energies of up to about 1 GeV and currents of up to 50 mA. The design and development of superconducting cavity modules, including coupler and HOM damper designs, are also of central importance for other existing and future accelerators and their tests are at the heart of the current ERL-TF goals. However, the ERL-TF could also provide a unique infrastructure for several applications that go beyond developing and testing the ERL technology at CERN. In addition to experimental studies of beam dynamics, operational and reliability issues in an ERL, it could equally serve for quench tests of superconducting magnets, as physics experimental facility on its own right or as test stand for detector developments. This contribution will describe the goals and the concept of the facility and the status of the R&D.

Jensen, Erik↗

TH-E-BRF-07: Raman Spectroscopy for Radiation Treatment Response Assessment in a Lung Metastases Mouse Model

Purpose: Raman spectroscopy is an optical spectroscopic method used to probe chemical information about a target tissue. Our goal was to investigate whether Raman spectroscopy is able to distinguish lung tumors from normal lung tissue and whether this technique can identify the molecular changes induced by radiation. Methods: 4T1 mouse breast cancer cells were implanted subcutaneously into the flanks of 6 Balb/C female mice. Four additional mice were used as “normal lung” controls. After 14 days, 3 mice bearing tumors received 6Gy to the left lung with 6MV photons and the other three were treated as “unirradiated tumor” controls. At a 24-hour time point, lungs were excised and the specimens were sectioned using a cryostat; alternating sections were either stained with hematoxylin and eosin (H and E) for evaluation by a pathologist or unstained for Raman measurements. 240 total Raman spectra were collected; 84 from normal lung controls; 63 from unirradiated tumors and 64 from tumors irradiated with 6Gy in a single fraction. Raman spectra were also collected from normal lung tissues of mice with unirradiated tumors. Principal component analysis (PCA) and discriminant function analysis (DFA) were performed to analyze the data. Results: Raman bands assignable to DNA/RNA showed prominent contributions in tumor tissues while Raman bands associated with hemoglobin showed strong contributions in normal lung tissue. PCA/DFA analysis identified normal lung tissue and tumor with 100% and 98.4% accuracy, respectively, relative to pathologic scoring. Additionally, normal lung tissues from unirradiated mice bearing tumors were classified as normal with 100% accuracy. In a model consisting of unirradiated and irradiated tumors identification accuracy was 79.4% and 93.8% respectively, relative to pathologic assessment. Conclusion: Initial results demonstrate the promise for Raman spectroscopy in the diagnosis normal vs. lung metastases as well as the assessment of radiation therapy response. Further investigations are needed to validate these results. This study was supported in part by a research grant from Varian Medical Systems, Palo Alto, CA.

60 APPLIED LIFE SCIENCES↗

Detection of high frequency intensity oscillations at RESEDA using the CASCADE detector

We have explored the technological potential of combining neutron resonance spin echo (NRSE) with the time-of-flight method in quasielastic neutron scattering (QENS) experiments. For these test measurements at the new NRSE instrument RESEDA (FRM II, Munich), we have employed CASCADE, one of the fastest neutron detectors in the world, developed at the University of Heidelberg. Conventionally, scintillation detectors are used, in order to detect neutron intensities with high time resolution. In contrast, we used the new CASCADE detector converting neutrons in thin {sup 10}B layers being capable of resolving neutron intensity modulations up to the megahertz regime. This fast detector allows us to abandon the last resonance flip coil of a standard NRSE setup. The classical spin echo signal is replaced by a time-modulated signal. In this setup, fast intensity modulations are present at the detector position. In order to demonstrate, that NRSE-CASCADE operates well up to detector frequencies of 10 MHz, we performed elastic polarization test measurements on a standard sample. The CASCADE detector is a multidetector accumulating counts in 128 x 128 pixels on a surface of 200 mm x 200 mm. We have analyzed the signal in 600 pixels, providing information about the spin phase reaching the detector and about the resolution function of this new variant tested at RESEDA.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electromagnetically induced transparency in paraffin-coated vapor cells

Antirelaxation coatings in atomic vapor cells allow ground-state coherent spin states to survive many collisions with the cell walls. This reduction in the ground-state decoherence rate gives rise to ultranarrow-bandwidth features in electromagnetically induced transparency (EIT) spectra, which can form the basis of, for example, long-time scale slow and stored light, sensitive magnetometers, and precise frequency standards. Here we study, both experimentally and theoretically, how Zeeman EIT contrast and width in paraffin-coated rubidium vapor cells are determined by cell and laser-beam geometry, laser intensity, and atomic density. Using a picture of Ramsey pulse sequences, where atoms alternately spend ''bright'' and ''dark'' time intervals inside and outside the laser beam, we explain the behavior of EIT features in coated cells, highlighting their unique characteristics and potential applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Slow-light dynamics from electromagnetically-induced-transparency spectra

We show how slow-light pulse delays in realistic electromagnetically-induced-transparency (EIT) media can be determined directly from static transmission spectra. Using only the measured EIT linewidth and off-resonant transmission, the absolute delay of a slow-light pulse in an optically thick, power-broadened medium can be simply and accurately determined, while capturing more complex optical pumping behavior.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Collider physics at HERA.

From 1992 to 2007, HERA, the first electron-proton collider, operated at cms energies of about 320 GeV and allowed the investigation of deep-inelastic and photoproduction processes at the highest energy scales accessed thus far. This review is an introduction to, and a summary of, the main results obtained at HERA during its operation.

43 PARTICLE ACCELERATORS↗