Engineering topics
Klein, M.
Publications and source records attributed to Klein, M..
The KATRIN superconducting magnets: Overview and first performance results
The KATRIN experiment aims for the determination of the effective electron anti-neutrino mass from the tritium beta-decay with an unprecedented sub-eV sensitivity. The strong magnetic fields, designed for up to 6 T, adiabatically guide β-electrons from the source to the detector within a magnetic flux of 191 Tcm 2 . A chain of ten single solenoid magnets and two larger superconducting magnet systems have been designed, constructed, and installed in the 70-m-long KATRIN beam line. The beam diameter for the magnetic flux varies from 0.064 m to 9 m, depending on the magnetic flux density along the beam line. Two transport and tritium pumping sections are assembled with chicane beam tubes to avoid direct "line-of-sight" molecular beaming effect of gaseous tritium molecules into the next beam sections. The sophisticated beam alignment has been successfully cross-checked by electron sources. In addition, magnet safety systems were developed to protect the complex magnet systems against coil quenches or other system failures. The main functionality of the magnet safety systems has been successfully tested with the two large magnet systems. The complete chain of the magnets was operated for several weeks at 70% of the design fields for the first test measurements with radioactive krypton gas. The stability of the magnetic fields of the source magnets has been shown to be better than 0.01% per month at 70% of the design fields. This paper gives an overview of the KATRIN superconducting magnets and reports on the first performance results of the magnets.
PERLE - Lattice Design and Beam Dynamics Studies
PERLE (Powerful ERL for Experiments) is a novel ERL test facility, initially proposed to validate choices for a 60 GeV ERL foreseen in the design of the LHeC and the FCC-eh. Its main thrust is to probe high current, CW, multi-pass operation with superconducting cavities at 802 MHz (and perhaps testing other frequencies of interest). With very high virtual beam power (~ 10 MW), PERLE offers an opportunity for controllable study of every beam dynamic effect of interest in the next generation of ERL design; becoming a ‘stepping stone' between present state-of-art 1 MW ERLs and future 100 MW scale applications. PERLE design features Flexible Momentum Compaction lattice architecture for six vertically stacked return arcs and a high-current, 6 MeV, photo-injector. With only one pair of 4 cavity cryomodules, 400 MeV beam energy can be reached in 3 re-circulation passes, with beam currents in excess of 15 mA. The beam is decelerated in 3 consecutive passes back to the injection energy, transferring virtually stored energy back to the RF. This unique facility will serve as a test-bed for high current ERL technologies, as well as a user facility in low energy electron and photon physics.
A Note on Effective Superpotentials and Kutasov Duality
Explore the source record for details and available documents.
Matrix Model, Kutasov Duality and Factorization of Seiberg-Witten Curves
Explore the source record for details and available documents.
On Supersymmetry Breaking in Intersecting Brane Models
Explore the source record for details and available documents.
Baryon content in a sample of 91 galaxy clusters selected by the South Pole Telescope at 0.2 <z < 1.25
We estimate total mass (M-500), intracluster medium (ICM) mass (M-ICM), and stellar mass (M-star) in a Sunyaev-Zel'dovich effect (SZE) selected sample of 91 galaxy clusters with masses M-500 greater than or similar to 2.5 x 10(14) M-circle dot and redshift 0.2 < z < 1.25 from the 2500 deg(2) South Pole Telescope SPT-SZ survey. The total masses M-500 are estimated from the SZE observable, the ICM masses M-ICM are obtained from the analysis of Chandra X-ray observations, and the stellar masses M-star are derived by fitting spectral energy distribution templates to Dark Energy Survey griz optical photometry and WISE or Spitzer near-infrared photometry. We study trends in the stellar mass, the ICM mass, the total baryonic mass, and the cold baryonic fraction with cluster halo mass and redshift. We find significant departures from self-similarity in the mass scaling for all quantities, while the redshift trends are all statistically consistent with zero, indicating that the baryon content of clusters at fixed mass has changed remarkably little over the past approximate to 9 Gyr. We compare our results to the mean baryon fraction (and the stellar mass fraction) in the field, finding that these values lie above (below) those in cluster virial regions in all but the most massive clusters at low redshift. Using a simple model of the matter assembly of clusters from infalling groups with lower masses and from infalling material from the low-density environment or field surrounding the parent haloes, we show that the measured mass trends without strong redshift trends in the stellar mass scaling relation could be explained by a mass and redshift dependent fractional contribution from field material. Similar analyses of the ICM and baryon mass scaling relations provide evidence for the so-called 'missing baryons' outside cluster virial regions.
Calibration of high voltages at the ppm level by the difference of $$^{83{\mathrm{m}}}$$Kr conversion electron lines at the KATRIN experiment
Not Available
First transmission of electrons and ions through the KATRIN beamline
The Karlsruhe Tritium Neutrino (KATRIN) experiment is a large-scale effort to probe the absolute neutrino mass scale with a sensitivity of 0.2 eV (90% confidence level), via a precise measurement of the endpoint spectrum of tritium β-decay. This work documents several KATRIN commissioning milestones: the complete assembly of the experimental beamline, the successful transmission of electrons from three sources through the beamline to the primary detector, and tests of ion transport and retention. In the First Light commissioning campaign of autumn 2016, photoelectrons were generated at the rear wall and ions were created by a dedicated ion source attached to the rear section; in July 2017, gaseous 83m Kr was injected into the KATRIN source section, and a condensed 83m Kr source was deployed in the transport section. In this paper we describe the technical details of the apparatus and the configuration for each measurement, and give first results on source and system performance. In conclusion, we have successfully achieved transmission from all four sources, established system stability, and characterized many aspects of the apparatus.
A multicomponent matched filter cluster confirmation tool for eROSITA: initial application to the RASS and DES-SV data sets
We describe a multi-component matched filter cluster confirmation tool (MCMF) designed for the study of large X-ray source catalogs produced by the upcoming X-ray all-sky survey mission eROSITA. We apply the method to confirm a sample of 88 clusters with redshifts $0.05<z<0.8$ in the recently published 2RXS catalog from the ROSAT all-sky survey (RASS) over the 208 deg$^2$ region overlapped by the Dark Energy Survey (DES) science verification (DES-SV) dataset. In our pilot study, we examine all X-ray sources, regardless of their extent. Our method employs a multi-color red sequence (RS) algorithm that incorporates the X-ray count rate and peak position in determining the region of interest for followup and extracts the positionally and color weighted optical richness $\lambda_{\mathrm{MCMF}}$ as a function of redshift for each source. Peaks in the $\lambda_{\mathrm{MCMF}}$-redshift distribution are identified and used to extract photometric redshifts, richness and uncertainties. The significances of all optical counterparts are characterized using the distribution of richnesses defined along random lines of sight. These significances are used to extract cluster catalogs and to estimate the contamination by random superpositions of unassociated optical systems. The delivered photometric redshift accuracy is $\delta z / (1+z)=0.010$. We find a well defined X-ray luminosity-$\lambda_{\mathrm{MCMF}}$ relation with an intrinsic scatter of $\delta \ln(\lambda_\mathrm{MCMF}| L_\mathrm{x})=0.21$. Matching our catalog with the DES-SV redMaPPer catalog yields good agreement in redshift and richness estimates; comparing our catalog with the South Pole Telescope (SPT) selected clusters shows no inconsistencies. SPT clusters in our dataset are consistent with the high mass extension of the RASS based $\lambda_{\mathrm{MCMF}}$-mass relation
Operation of a quantum dot in the finite-state machine mode: Single-electron dynamic memory
A single electron dynamic memory is designed based on the non-equilibrium dynamics of charge states in electrostatically defined metallic quantum dots. Using the orthodox theory for computing the transfer rates and a master equation, we model the dynamical response of devices consisting of a charge sensor coupled to either a single and or a double quantum dot subjected to a pulsed gate voltage. We show that transition rates between charge states in metallic quantum dots are characterized by an asymmetry that can be controlled by the gate voltage. This effect is more pronounced when the switching between charge states corresponds to a Markovian process involving electron transport through a chain of several quantum dots. By simulating the dynamics of electron transport we demonstrate that the quantum box operates as a finite-state machine that can be addressed by choosing suitable shapes and switching rates of the gate pulses. We further show that writing times in the ns range and retention memory times six orders of magnitude longer, in the ms range, can be achieved on the double quantum dot system using experimentally feasible parameters, thereby demonstrating that the device can operate as a dynamic single electron memory.
Commissioning of the vacuum system of the KATRIN Main Spectrometer
The KATRIN experiment will probe the neutrino mass by measuring the β-electron energy spectrum near the endpoint of tritium β-decay. We performed an integral energy analysis by an electro-static spectrometer (``Main Spectrometer''), an ultra-high vacuum vessel with a length of 23.2 m, a volume of 1240 m 3 , and a complex inner electrode system with about 120 000 individual parts. The strong magnetic field that guides the β-electrons is provided by super-conducting solenoids at both ends of the spectrometer. Its influence on turbo-molecular pumps and vacuum gauges had to be considered. Furthermore, a system consisting of 6 turbo-molecular pumps and 3 km of non-evaporable getter strips has been deployed and was tested during the commissioning of the spectrometer. In this paper the configuration, the commissioning with bake-out at 300 °C, and the performance of this system are presented in detail. The vacuum system has to maintain a pressure in the 10 -11 mbar range. We demonstrated that the performance of the system is already close to these stringent functional requirements for the KATRIN experiment, which will start at the end of 2016.
Zeeman spectroscopy of the internal transition {sup 4}T{sub 1} to {sup 6}A{sub 1} of Fe{sup 3+} ions in wurtzite GaN
Internal transitions of Fe{sup 3+} ions in wurtzite gallium nitride were analyzed by means of photoluminescence, Zeeman, and transmission spectroscopy in order to investigate the fine structure. Magnetic fields up to 14 T were applied perpendicular or parallel to the crystal c-axis, causing a characteristic splitting pattern of the luminescence related to the transition from the {sup 4}T{sub 1} excited state to the {sup 6}A{sub 1} ground state of Fe{sup 3+}. The complete Hamiltonian matrix is constructed taking into account the crystal field in cubic and trigonal symmetry, spin-orbit interaction, and the influence of external magnetic fields. Numerical solution yields the exact energy level scheme of the excited state {sup 4}G of Fe{sup 3+} ions in GaN, which partly revises assumptions based on a qualitative treatment considering group theory only and invoking the influence of a Jahn-Teller effect. The coincidence of the calculated energy levels with the experimental data verifies the derived fine structure of the 3d metal ion.
A large hadron electron collider at CERN
This document provides a brief overview of the recently published report on the design of the Large Hadron Electron Collider (LHeC), which comprises its physics programme, accelerator physics, technology and main detector concepts. The LHeC exploits and develops challenging, though principally existing, accelerator and detector technologies. This summary is complemented by brief illustrations of some of the highlights of the physics programme, which relies on a vastly extended kinematic range, luminosity and unprecedented precision in deep inelastic scattering. Illustrations are provided regarding high precision QCD, new physics (Higgs, SUSY) and eletron-ion physics. The LHeC is designed to run synchronously with the LHC in the twenties and to achieve an integrated luminosity of O(100)fb –1 . It will become the cleanest high resolution microscope of mankind and will substantially extend as well as complement the investigation of the physics of the TeV energy scale, which has been enabled by the LHC.
A Statistical Sampling Method for Uncertainty Analysis with SCALE and XSUSA
Explore the source record for details and available documents.
Measurement of beauty photoproduction near threshold using di-electron events with the H1 detector at HERA
The cross section for $ep \to e b\bar{b} X$ in photoproduction is measured with the H1 detector at the $ep$-collider HERA. The decay channel $b\bar{b} \to ee X^\prime$ is selected by identifying the semi-electronic decays of the b-quarks. The total production cross section is measured in the kinematic range given by the photon virtuality $Q^2 \le 1 GeV^2$, the inelasticity $0.05 \le y \le 0.65$ and the pseudorapidity of the $b$-quarks $|\eta(b)|$,$|\eta(\bar{b})| \le 2$. The differential production cross section is measured as a function of the average transverse momentum of the beauty quarks <$P_T$(b)> down to the threshold. The results are compared to next-to-leading-order QCD predictions.
Comparison of XSUSA and 'two-step' approaches for full-core uncertainty quantification
While there are multiple sources of error that are introduced into the standard computational regime for simulating reactor cores, rigorous uncertainty analysis methods are available primarily for quantifying the effects of cross section uncertainties. Two methods for propagating cross section uncertainties through core simulators are the XSUSA statistical approach and the 'Two-Step' method. The XSUSA approach, which is based on the SUSA code package, is fundamentally a stochastic sampling method. Alternatively, the Two-Step method utilizes generalized perturbation theory in the first step and stochastic sampling in the second step. The consistency of these two methods in quantifying uncertainties in the multiplication factor and in the core power distribution will be examined in the framework of phase 1-3 of the UAM Benchmark. Using the TMI core as a base model for analysis, the XSUSA and Two-Step methods are applied with certain limitations and the results are compared to those produced by other stochastic sampling-based codes. Based on the uncertainty analysis results, conclusions are made for which method is currently a more viable option for computing uncertainties in burnup and transient calculations. (authors)
Development of a statistical sampling method for uncertainty analysis with SCALE
A new statistical sampling sequence called Sampler has been developed for the SCALE code system. Random values for the input multigroup cross sections are determined by using the XSUSA program to sample uncertainty data provided in the SCALE covariance library. Using these samples, Sampler computes perturbed self-shielded cross sections and propagates the perturbed nuclear data through any specified SCALE analysis sequence, including those for criticality safety, lattice physics with depletion, and shielding calculations. Statistical analysis of the output distributions provides uncertainties and correlations in the desired responses. (authors)