Search NASA⌕ Search

Engineering topics

Kleissl, Jan

Publications and source records attributed to Kleissl, Jan.

Brick Schema Standardized Plug Load Control Strategies for Load Reduction: Preprint

Plug loads comprise a significant percentage of commercial building energy consumption. Applying intelligent controls to turn off plug loads when unused can provide dynamic load reduction and flexibility, which are key traits of grid-interactive efficient buildings. This capability is important for equitable decarbonization as it can enable disadvantaged communities to electrify buildings without costly upgrades to electrical infrastructure. In this work, we present the effectiveness of various control strategies along with the operational lessons that informed their design. During a three-year period, we operated over 600 smart outlets in 12 university office buildings. The attached plug loads consisted primarily of printers, TVs, water dispensers, and copiers. After recording baseline power measurements for one year, we designed plug load control (PLC) strategies for each plug load type, use, and for different risk tolerance levels because PLC can potentially be disruptive to daily work. We used the Brick Schema to facilitate the management of plug load locations and other metadata. For advanced controls, we integrated the smart plugs with heating, ventilation, and air conditioning (HVAC) systems through the campus building automation system. We found static schedules to be the least disruptive and most predictable for occupants, resulting in 38% and 66% energy savings in two studies. For printers, print server-triggered PLC produced 86% savings, the highest of all strategies with minimal occupant impact. Scheduling of water dispensers and digital signage TVs produced 49% and 70% savings respectively with opportunities to improve performance with the use of HVAC occupancy data.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Integration of a Smart Outlet-Based Plug Load Management System with a Building Automation System

The growth of and reliance on renewable energy necessitate a multi-pronged approach to achieve grid reliability and economics. As they represent a notable portion of U.S. energy consumption, commercial buildings must play an active role in this effort. Conserving energy and responding to grid conditions through demand flexibility can be achieved through the integration of major building systems. Integration of plug and process loads with lighting and heating, ventilation, and air conditioning systems maximizes the effectiveness of integrated building energy management. In this research, we demonstrate the integration of smart outlets into a building automation system. We cover the installation process as well as the architecture required for smart outlets to communicate data to the building automation system and to receive commands back. After recording power measurements for one week as a baseline, we configured the building automation system to turn the smart outlets on and off according to a set schedule. This resulted in energy savings of 66% during 1 week on 25 plug loads. This work demonstrates that grid-interactive efficient buildings are achievable through building system integration.

building automation system↗

Graph theory and nighttime imagery based microgrid design

Reducing the duration and frequency of blackouts in remote communities poses an engineering challenge for grid operators. Outage effects can also be mitigated locally through microgrids. This paper develops a systematic procedure to account for these challenges by creating microgrids prioritizing high value assets within vulnerable communities. Nighttime satellite imagery is used to identify vulnerable communities. Using an asset classification and rating system, multi-asset clusters within these communities are prioritized. Infrastructure data, geographic information systems, satellite imagery, and spectral clustering are used to form and rank microgrid candidates. A microgrid sizing algorithm is included to guide through the microgrid design process. Finally, an application of the methodology is presented using real event, location, and asset data.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Effects of Surface and Top Wind Shear on the Spatial Organization of Marine Stratocumulus-Topped Boundary Layers

Typically, the convective nature of Stratocumulus topped boundary layers (STBL) involves the motion of updrafts and downdrafts, driven by surface fluxes and radiative cooling, respectively. The balance between shear and buoyant forcings at the surface can determine the organization of updrafts between cellular and roll structures. We investigate the effect of varying shear at the surface and top of the STBL using Large Eddy Simulations, taking DYCOMS II RF01 as a base case. We focus on spatial identification of the following features: coherent updrafts and downdrafts, and observe how they are affected by varying shear. Stronger surface shear organizes the updrafts in rolls, causes less well-mixed thermodynamic profiles, and decreases cloud fraction and liquid water path (LWP). Stronger top shear also decreases cloud fraction and LWP more than surface shear, by thinning the cloud from the top. Features with stronger top than surface shear are associated with a net downward momentum transport and show early signs of decoupling. Classifying updrafts and downdrafts based on their vertical span and horizontal size confirms the dominance of tall objects spanning the whole STBL. Tall objects occupy 30% of the volume in the STBL, while short ones occupy less than 1%. For updraft and downdraft fluxes, these tall objects explain 65% of the vertical velocity variance and 83% of the buoyancy flux, on average. Stronger top shear also weakens the contribution of downdrafts to the turbulent fluxes and tilts the otherwise vertical development of updrafts.

54 ENVIRONMENTAL SCIENCES↗

On the Parameterization of Convective Downdrafts for Marine Stratocumulus Clouds

The role of nonlocal transport on the development and maintenance of marine stratocumulus (Sc) clouds in coarse-resolution models is investigated, with a special emphasis on the downdraft contribution. A new parameterization of cloud-top-triggered downdrafts is proposed and validated against large-eddy simulation (LES) for two Sc cases. The applied nonlocal mass-flux scheme is part of the stochastic multiplume eddy-diffusivity/mass-flux (EDMF) framework decomposing the turbulent transport into local and nonlocal contributions. The complementary local turbulent transport is represented with the Mellor–Yamada–Nakanishi–Niino (MYNN) scheme. This EDMF version has been implemented in the Weather Research and Forecasting (WRF) single-column model (SCM) and tested for three model versions: without mass flux, with updrafts only, and with both updrafts and downdrafts. In the LES, the downdraft and updraft contributions to the total heat and moisture transport are comparable and significant. The WRF SCM results show a good agreement between the parameterized downdraft turbulent transport and LES. While including updrafts greatly improves the modeling of Sc clouds over the simulation without mass flux, the addition of downdrafts is less significant, although it helps improve the moisture profile in the planetary boundary layer.

Wu, Elynn↗

Solar-Reflective “Cool” Walls: Benefits, Technologies, and Implementation

Raising the albedo (solar reflectance) of a building’s walls reduces unwanted solar heat gain in the cooling season. This saves electricity and lowers peak power demand by decreasing the need for air conditioning. It can also cool the outside air, which can mitigate the urban heat island effect and also improve air quality by slowing the reactions that produce smog. This project quantified the energy savings, peak demand reduction, urban cooling, and air quality improvements attainable from solar-reflective “cool” walls in California; collaborated with industry to assess the performance of existing cool-wall technologies, and to develop innovative cool-wall solutions; and worked with state and federal government agencies, utilities, and industry to create a cool-wall infrastructure, including application guidelines, a product rating program, incentives, and building code credits. Simulations indicate that cool walls provide annual energy savings, peak demand reduction, annual emission reduction, and summer heat island mitigation benefits comparable to those yielded by cool roofs, and are helpful across California and in most of the southern half of the United States (that is, in U.S. climate zones 1—4). Natural exposure trials conducted at three sites in California and another three sites across the United States indicate that cool-wall materials tend to stay clean and reflective. Significant advances were made in novel cool-wall technologies, such as fluorescent cool pigments that expand the color palette for cool-wall products. We prepared guidelines for the climate- and building-appropriate use of cool walls, convened a stakeholder workshop, and created a working group. Ongoing efforts seek to introduce or expand cool-wall provisions in building energy standards, green building programs, and energy efficiency incentive programs, and to develop a cool-wall product rating system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Solar-Reflective “Cool” Walls: Benefits, Technologies, and Implementation

Raising the albedo (solar reflectance) of a building’s walls reduces unwanted solar heat gain in the cooling season. This saves electricity and lowers peak power demand by decreasing the need for air conditioning. It can also cool the outside air, which can mitigate the urban heat island effect and also improve air quality by slowing the reactions that produce smog. This project quantified the energy savings, peak demand reduction, urban cooling, and air quality improvements attainable from solar-reflective “cool” walls in California; collaborated with industry to assess the performance of existing cool-wall technologies, and to develop innovative cool-wall solutions; and worked with state and federal government agencies, utilities, and industry to create a cool-wall infrastructure, including application guidelines, a product rating program, incentives, and building code credits. Simulations indicate that cool walls provide annual energy savings, peak demand reduction, annual emission reduction, and summer heat island mitigation benefits comparable to those yielded by cool roofs, and are helpful across California and in most of the southern half of the United States (that is, in U.S. climate zones 1—4). Natural exposure trials conducted at three sites in California and another three sites across the United States indicate that cool-wall materials tend to stay clean and reflective. Significant advances were made in novel cool-wall technologies, such as fluorescent cool pigments that expand the color palette for cool-wall products. We prepared guidelines for the climate- and building-appropriate use of cool walls, convened a stakeholder workshop, and created a working group. Ongoing efforts seek to introduce or expand cool-wall provisions in building energy standards, green building programs, and energy efficiency incentive programs, and to develop a cool-wall product rating system.

utility incentives↗

Inversion Reduction Method for Real and Complex Distribution Feeder Models

We report the proliferation of distributed generation on distribution feeders triggers a large number of integration and planning studies. Further, the complexity of distribution feeder models, short simulation time steps, and long simulation horizons rapidly render studies computational burdensome. To mend this issue, we propose a methodology for reducing the number of nodes, loads, generators, line, and transformers of p-phase distribution feeders with unbalanced loads and generation, non-symmetric wire impedance, mutual coupling, shunt capacitance, and changes in voltage and phase. The methodology is derived on a constant power load assumption and employs a Gaussian elimination inversion technique to design the reduced feeder. Compared to previous work by the authors, the inversion reduction takes half the time and voltage errors after reduction are reduced by an order of magnitude. Using a snapshot simulation the reduction is tested on six additional publicly available feeders with a maximum voltage error 0.0075 p.u. regardless of feeder size or complexity, and typical errors on the order of 1 × 10 -4 p.u. Lastly, for a day long quasi-static time series simulation on the UCSD A feeder, errors are shown to increase with changes in loading when a large number of buses removed, but shows less variation for less than 85% of buses removed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Sky camera geometric calibration using solar observations

A camera model and associated automated calibration procedure for stationary daytime sky imaging cameras is presented. The specific modeling and calibration needs are motivated by remotely deployed cameras used to forecast solar power production where cameras point skyward and use 180° fisheye lenses. Sun position in the sky and on the image plane provides a simple and automated approach to calibration; special equipment or calibration patterns are not required. Sun position in the sky is modeled using a solar position algorithm (requiring latitude, longitude, altitude and time as inputs). Sun position on the image plane is detected using a simple image processing algorithm. The performance evaluation focuses on the calibration of a camera employing a fisheye lens with an equisolid angle projection, but the camera model is general enough to treat most fixed focal length, central, dioptric camera systems with a photo objective lens. Calibration errors scale with the noise level of the sun position measurement in the image plane, but the calibration is robust across a large range of noise in the sun position. In conclusion, calibration performance on clear days ranged from 0.94 to 1.24 pixels root mean square error.

54 ENVIRONMENTAL SCIENCES↗

Coupling sky images with radiative transfer models: a new method to estimate cloud optical depth

A method for retrieving cloud optical depth ( τ c ) using a UCSD developed ground-based sky imager (USI) is presented. The radiance red–blue ratio (RRBR) method is motivated from the analysis of simulated images of various τ c produced by a radiative transfer model (RTM). From these images the basic parameters affecting the radiance and red–blue ratio (RBR) of a pixel are identified as the solar zenith angle ( θ 0 ), τ c , solar pixel angle/scattering angle ( θ s ), and pixel zenith angle/view angle ( θ z ). The effects of these parameters are described and the functions for radiance, I λ τ c , θ 0 , θ s , θ z , and RBR τ c , θ 0 , θ s , θ z are retrieved from the RTM results. RBR, which is commonly used for cloud detection in sky images, provides non-unique solutions for τ c , where RBR increases with τ c up to about τ c = 1 (depending on other parameters) and then decreases. Therefore, the RRBR algorithm uses the measured I λ meas θ s , θ z , in addition to RBR meas θ s , θ z , to obtain a unique solution for τ c . The RRBR method is applied to images of liquid water clouds taken by a USI at the Oklahoma Atmospheric Radiation Measurement (ARM) program site over the course of 220 days and compared against measurements from a microwave radiometer (MWR) and output from the Min et al. (2003) method for overcast skies. τ c values ranged from 0 to 80 with values over 80, being capped and registered as 80. A τ c RMSE of 2.5 between the Min et al. (2003) method and the USI are observed. The MWR and USI have an RMSE of 2.2, which is well within the uncertainty of the MWR. In conclusion, the procedure developed here provides a foundation to test and develop other cloud detection algorithms.

54 ENVIRONMENTAL SCIENCES↗

Validation of the NSRDB-SUNY global horizontal irradiance in California

Satellite derived global horizontal solar irradiance (GHI) from the SUNY modeled dataset in the National Solar Radiation Database (NSRDB) was compared to measurements from 27 weather stations in California during the years 1998-2005. The statistics of spatial and temporal differences between the two datasets were analyzed and related to meteorological phenomena. Overall mean bias errors (MBE) of the NSRDB-SUNY indicated a GHI overprediction of 5%, which is smaller than the sensor accuracy of ground stations. However, at coastal sites, year-round systematic positive MBEs in the NSRDB-SUNY data up to 18% were observed and monthly MBEs increased up to 54% in the summer months during the morning. These differences were explained by a tendency for the NSRDB-SUNY model to overestimate GHI under cloudy conditions at the coast during summer mornings. A persistent positive evening MBE which was independent of site location and cloudiness occurred at all stations and was explained by an error in the time-shifting method applied in the NSRDB-SUNY. A correction method was derived for these two errors to improve the accuracy of the NSRDB-SUNY data in California. (author)

14 SOLAR ENERGY↗

Quantifying the Dependencies of Rooftop Temperatures on Albedo

The thermal properties of building materials directly effect the conditions inside of buildings Heat transfer is not a primary design driver in building design. Rooftop modifications lower heat transfer, which lowers energy consumption and costs. The living environmental laboratory attitude at UCSD makes it the perfect place to test the success of these modifications.

Dominquez, Anthony↗