Search NASASearch

Engineering topics

Klepczynski, W. J.

Publications and source records attributed to Klepczynski, W. J..

Comparison of LASSO and GPS time transfers

The LASSO is a technique which should allow the comparison of remote atomic clocks with sub-nanosecond precision and accuracy. The first successful time transfer using LASSO has been carried out between the Observatoire de la Cote d'Azur in France and the McDonald Observatory in Texas, United States. This paper presents a preliminary comparison of LASSO time transfer with GPS common-view time transfer.

Lewandowski, W.

Performance data of US Naval Observatory VLG-11 hydrogen masers since September, 1983

In 1983, two VLC-11 masers were delivered to the U.S. Naval Observatory by the Smithsonian Astrophysical Observatory. Last year the short-term stability of these masers was reported and the effect of this short-term stability on timekeeping performance was examined. Since the date of installation, 13 September 1983, data on the masers' long-term performance have been accumulated. The Allan variance, agma(tau), of the relative frequency between the masers reaches a minimum of about 4 parts in 10 to the 16th power at averaging times 5,000 seconds and rises at longer averaging times due, at least partly, to systematic frequency drift. The systematic frequency drifts, expressed in units of fractional frequency difference per day are discussed.

Vessot, R. F. C.

Comparison of VLBI, TV and traveling clock techniques for time transfer

A three part experiment was conducted to develop and compare time transfer techniques. The experiment consisted of (1) a very long baseline interferometer (VLBI), (2) a high precision portable clock time transfer system between the two sites, and (3) a television time transfer. A comparison of the VLBI and traveling clock shows each technique can perform satisfactorily at the five nsec level. There was a systematic offset of 59 nsec between the two methods, which we attributed to a difference in epochs between VLBI formatter and station clock. The VLBI method had an internal random error of one nsec at the three sigma level for a two day period. Thus, the Mark II system performed well, and VLBI shows promise of being an accurate method of time transfer. The TV system, which had technical problems during the experiment, transferred time with a random error of about 50 nsec.

Spencer, J. H.

The USNO/NRL Green Bank interferometer program

Application of the connected-element radio interferometer of the National Radio Astronomy Observation in Green Bank, West Virginia to the determination of improved source coordinates, astronomical constants, and variations in Earth rotation parameters is discussed. It is concluded that because of the brevity and discontinuity of the data so far no reliable conclusions regarding the accuracy of the data can be drawn.

Klepczynski, W. J.

Synchronization of clocks by very-long-baseline interferometry

Two hydrogen-maser clocks, one at Haystack Observatory and one at the National Radio Astronomy Observatory, were synchronized by means of observations of several extragalactic radio sources on March 28, and again on September 23, 1977. Observations were made sequentially in eight 360-kHz bands distributed between about 8.4 and 8.5 GHz with spacings designed to enable the group-delay difference between the signals received at the two observatories from a given source to be estimated unambiguously, within an uncertainty of less than 1 ns set by receiver noise. The epoch and the rate differences between the observatories' clocks for each experiment were estimated by analysis of observations that spanned several hours. The application of corrections for the contributions to the delays of the antennas, feeds, receiver systems, and recorders yielded absolute determinations of the clock epoch differences. During each experiment, portable cesium clocks were flown from the U.S. Naval Observatory to the observatories and back. The traveling-clock data, analyzed in each case after the VLBI synchronization had been completed, confirmed the VLBI results to within 18 and 14 ns for the first and second experiments, respectively.

Clark, T. A.

Time transfer with the NAVSTAR global positioning system

The NAVSTAR global positioning system (GPS) was evaluated and tested in terms of performance. A variety of operational and technical issues were addressed which characterize the performance of the system. The precision and accuracy of the transfer of GPS time to the static user were measured and a base of information was developed that would support and expediate efforts to develop and evaluate specialized user equipment to exhibit the operational GPS's precision timing characteristics.

Roth, B. D.

Two-Way Time Transfer via Geostationary Satellites NRC/NBS, NRC/USNO and NBS/USNO via Hermes and NRC/LPTF (France) via Symphonie

In most of the experiments, 1 pps pulses of the station atomic clocks were exchanged between the partners, and a cubic equation was fitted to the 1000 to 2000 second measurements. The equations were exchanged and substracted to obtain the time difference of the stations. The standard deviation in the fit of the equations varied, depending on conditions, from 1.5 ns to 16 ns. For the last month of the Hermes experiment, a 1 MHz signal was used, giving a standard deviation of 0.18 ns. The comparison of the time scales via satellite and via Loran-C (BIH Circular D) show clearly that some Loran-C links are very good, but that the NBS link varies by 1 micron s. Via the satellite the frequencies of the time scales can be compared with an accuracy of 2 x 10 to the minus 14 power.

Costain, C.

Two-way time transfers between NRC/NBS and NRC/USNO via the Hermes (CTS) satellite

At each station the differences were measured between the local UTC seconds pulse and the remote UTC pulse received by satellite. The difference between the readings, if station delays are assumed to be symmetrical, is two times the difference between the clocks at the two ground station sites. Over a 20-minute period, the precision over the satellite is better than 1 ns. The time transfer from NRC to the CRC satellite terminal near Ottawa and from NBS to the Denver HEW terminal was examined.

Costain, C. C.