Search NASA⌕ Search

Engineering topics

Knapp, P F

Publications and source records attributed to Knapp, P F.

At least 19 records

Enhanced keV peak power and yield using twisted pair 'cables' in a z-pinch

Individual wires in a z-pinch were replaced with twisted pair 'cables' of similar linear mass on the COBRA pulsed power generator, resulting in peak power and yield increases in radiation above 1 keV. A cable is defined here as two or more fine wires twisted together to form a continuous strand with a wavelength ({lambda}{sub t}) dependent on the twists per unit length. The magnitude of {lambda}{sub t} appears to play a strong role in these increases, with the largest gains found for a {lambda}{sub t} of Almost-Equal-To 0.75 mm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time and space resolved measurement of the electron temperature, mass density and ionization state in the ablation plasma between two exploding Al wires

We have determined the properties of plasma around and between two exploding wires using high-resolution x-ray absorption spectroscopy. Plasma densities and temperatures ranging from Greater-Than-Or-Equivalent-To 0.1g/cm{sup 3} and a few eV to less than 0.01 g/cm{sup 3} and 30 eV have been measured in experiments at Cornell University with two 40 {mu}m aluminum (Al) wires spaced 1 mm apart driven by {approx}150 kA peak current pulses with 100 ns rise time. The wire plasma was backlit by the 1.4-1.6 keV continuum radiation produced by a Mo wire X-pinch. The spectrometer employed two spherically bent quartz crystals to record the absorption and backlighter spectra simultaneously. The transition between the dense Al wire core and the coronal plasma is seen as a transition from cold K-edge absorption to Mg-, Na-, and finally Ne-like absorption at the boundary. In the plasma that accumulates between the wires, ionization states up to C-Like Al are observed. The spectrometer geometry and {approx}2{mu}m X-pinch source size provide 0.3 eV spectral resolution and 20 {mu}m spatial resolution enabling us to see 1s{yields} 2p satellite transitions as separate lines as well as O-, F-, and Ne-like 1s{yields} 3p transitions that have not been seen before. A step wedge was used to calibrate the transmission, enabling density to be measured within a factor of two and temperature to be measured within {+-}25%. A genetic algorithm was developed to fit synthetic spectra calculated using the collisional-radiative code SCRAM to the experimental spectra. In order to obtain agreement it was necessary to assume multiple plasma regions with variable thicknesses, thereby allowing the inferred plasma conditions to vary along the absorption path.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Hybrid X-pinches

Results from experimental studies of a hybrid X-pinch with an initial configuration in the form of a high-current diode with conical tungsten electrodes spaced by 1-2 mm and connected to one another with 20- to 100-{mu}m-diameter wires are presented. The experiments were carried out at four facilities with a current amplitude from 200 to 1000 kA and front duration from 45 to 200 ns. It is shown that, in spite of their simpler configuration, hybrid X-pinches with a short rise time of the current pulse (50-100 ns) are highly competitive with standard X-pinches in the generated soft X-ray power and the formation of a single hot spot in them is much more stable, while hard X-ray emission is almost absent. The possibility of using hybrid X-pinches as soft X-ray sources for point projection X-ray imaging of plasma objects is considered.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High resolution absorption spectroscopy of exploding wire plasmas using an x-pinch x-ray source and spherically bent crystal

We present here the use of absorption spectroscopy of the continuum radiation from x-pinch-produced point x-ray sources as a diagnostic to investigate the properties of aluminum plasmas created by pulsed power machines. This technique is being developed to determine the charge state, temperature, and density as a function of time and space under conditions that are inaccessible to x-ray emission spectroscopic diagnostics. The apparatus and its characterization are described, and the spectrometer dispersion, magnification, and resolution are calculated and compared with experimental results. Spectral resolution of about 5000 and spatial resolution of about 20 {mu}m are demonstrated. This spectral resolution is the highest available to date in an absorption experiment. The beneficial properties of the x-pinch x-ray source as the backlighter for this diagnostic are the small source size (<5 {mu}m), smooth continuum radiation, and short pulse duration (<0.1 ns). Results from a closely spaced (1 mm) exploding wire pair are shown and the general features are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hybrid X-pinch with conical electrodes

A hybrid X-pinch configuration consisting of solid conical electrodes connected by a wire has been tested on a 45 ns risetime, 500 kA peak current pulsed power generator. Wires of different materials were loaded through holes in the cones; wire lengths were varied from 0.6 to 2 mm. Most of these hybrid X-pinches generated an intense single burst of soft x-rays and developed a single hot spot that was of micron-scale size. Hybrid X-pinches generate less hard x-ray intensity than standard X-pinches.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quasimonochromatic x-ray backlighting on the COrnell Beam Research Accelerator (COBRA) pulsed power generator

Monochromatic x-ray backlighting has been employed with great success for imaging of plasmas with strong self-emission such as x-pinches and wire array z-pinches. However, implementation of a monochromatic backlighting system typically requires extremely high quality spherically bent crystals which are difficult to manufacture and can be prohibitively expensive. Furthermore, the crystal must have a direct line of sight to the object, which typically emits copious amounts of radiation and debris. We present a quasimonochromatic x-ray backlighting system which employs an elliptically bent mica crystal as the dispersive element. In this scheme a narrow band of continuum radiation is selected for imaging, instead of line radiation in the case of monochromatic imaging. The flat piece of mica is bent using a simple four-point bending apparatus that allows the curvature of the crystal to be adjusted in situ for imaging in the desired wavelength band. This system has the advantage that it is very cost effective, has a large aperture, and is extremely flexible. The principles of operation of the system are discussed and its performance is analyzed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Growth and saturation of the axial instability in low wire number wire array Z pinches

The growth of the axial instability in low wire number wire array Z pinches using a 100 ns rise time, 1 MA pulsed power accelerator is examined. The axial instability manifests itself as a quasiperiodic variation of the radius of the coronal plasma along each wire and a consequent modulation of the rate of ablation of material from the dense wire core. The dominant wavelength of the modulation becomes constant late in time. In this work laser shadowgraphy is used to measure the growth of the wavelength and amplitude of the instability as well as the size of the coronal plasma in aluminum wire arrays from the time of plasma formation to the time the wavelength seen late in time is reached. Using magnetic probes, the distribution of current and magnetic topology are also investigated. It is found that a distinct change in magnetic field topology associated with the onset of advection of current to the array axis by the streaming wire-ablation plasma appears to be responsible for ending the growth of the axial instability and initiating the quasisteady state ablation phase of the wire array Z pinch.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Initial experiments using radial foils on the Cornell Beam Research Accelerator pulsed power generator

A novel technique involving radial foil explosions can produce high energy density plasmas. A current flows radially inward in a 5 mum thin aluminum foil from a circular anode, which contacts the foil on its outer rim, to the cathode, which connects to the foil at its geometrical center. When using small 'pin' cathodes (approx1 mm in diameter) on a medium size pulsed-current generator such as the Cornell Beam Research Accelerator, the central magnetic field approaches 400 T, yielding magnetic pressures larger than 0.5 Mbar. While the dynamics is similar to radial wire arrays, radial foil discharges have very distinct characteristics. First a plasma jet forms, with densities near 5x10{sup 18} cm{sup -3}. JxB forces lift the foil upward with velocities of approx200 km/s. A plasma bubble with electron densities superior to 5x10{sup 19} cm{sup -3} then develops, surrounding a central plasma column, carrying most of the cathode current. X-ray bursts coming from the center of this column were recorded at 1 keV photon energy. As the magnetic bubble explodes, ballistic plasma projectiles form and escape with velocities exceeding 300 km/s. Laser shadowgraphy and interferometry, gated extreme ultraviolet imaging and miniature Bdot probes are used to investigate the magnetohydrodynamics properties of such configurations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Symmetric multilayer megampere X-pinch

Raising the power of X-ray emission from an X-pinch by increasing the pinch current to the megampere level requires the corresponding increase in the initial linear mass of the load. This can be achieved by increasing either the number of wires or their diameter. In both cases, special measures should be undertaken to prevent the formation of a complicated configuration with an uncontrolled spatial structure in the region of wire crossing, because such a structure breaks the symmetry of the neck formed in the crossing region, destabilizes plasma formation, and degrades X-ray generation. To improve the symmetry of the wire crossing region, X-pinch configurations with a regular multilayer arrangement of wires in this region were proposed and implemented. The results of experiments with various symmetric X-pinch configurations on the COBRA facility at currents of {approx}1MA are presented. It is shown that an X-pinch with a symmetric crossing region consisting of several layers of wires made of different materials can be successfully used in megampere facilities. The most efficient combinations of wires in symmetric multilayer X-pinches are found in which only one hot spot forms and that are characterized by a high and stable soft X-ray yield.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Azimuthally correlated ablation between z-pinch wire cores

Azimuthally correlated wire core ablation was compared for closely spaced versus widely spaced wires in a 1 MA Z-pinch. X-ray point-projection diagnostics revealed that 240 {mu}m spaced wires exhibited a correlation coefficient approaching unity in both real space and in k-space. This correlated ablation between wires at a fixed axial location is believed to occur due to an enhanced, localized Joule heating. Wires separated by 2.47 mm or greater were uncorrelated in real space, but correlated in k-space, indicating the ablation structure between wires was shifted in phase.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nested multilayered X pinches for generators with mega-ampere current level

A symmetric X pinch configuration that is conducive to using large numbers of wires on {>=}1 MA pulsed power generators has been tested at 1 MA. Using an initial configuration of wires before their twisting, similar to nested cylindrical wire arrays, enables a geometrically simple, compact, multilayer wire configuration at the X pinch crossing region. Multilayer X pinches with the same or different materials in the inner and outer wire layers were tested. Optimization resulted in X pinch radiation sources with peak power comparable to the most successful single layer X pinch, but with a compact, single bright X radiation source more reliably obtained using the nested configuration.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Physics of Multi-Planar and Compact Cylindrical Wire Arrays Implosions on University-Scale Z-pinch Generators

The presented research focuses on investigation of Z-pinch plasma formation, implosion, and radiation characteristics as a function of the load configuration. The single planar and multi-planar wire arrays as well as compact cylindrical wire arrays were studied on the 1.3 MA UNR Zebra and 1 MA Cornell COBRA generators. The largest yields and powers were found for W and Mo double planar and compact wire arrays. A possibility of radiation pulse shaping was demonstrated. Two types of bright spots were observed in plasmas. A comparison of Mo double planar and compact wire array data indicates the possibility that the same heating mechanism operates during the final implosion and stagnation stages.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nested X Pinches on the COBRA Generator

Recent results of X pinch studies on the COBRA generator at Cornell University (peak current up to 1.2 MA and rise time of 100 ns) are presented. Using an initial configuration of wires before their twisting, similar to nested cylindrical wire arrays enables the assembly of a symmetric configuration at the X pinch crossing region. It also enables an investigation of multilayered X pinches. X pinches with different configurations, including with different materials in the inner and outer wire layers, were tested.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optical Spectroscopy Experiments on the 500 kA XP Pulsed-Power Generator

Recent experiments on the 500 kA XP pulsed-power generator at Cornell University have explored the properties of optical spectra in single wires and wire arrays. In the single wire experiments, {approx}1% of the current from XP has been directed through the single wire. Spectra have been recorded using a half-meter spectrometer and a CCD camera located adjacent to the XP pulser. We are studying the visible spectra emitted by the wires and the background light from the machine hardware in order to identify the levels of current per wire for which visible spectroscopy might provide a means to measure magnetic field strength. We have also investigated the dependence of single wire visible spectra on the current, which was measured using a calibrated non-integrating Rogowski coil. UV and XUV diodes were employed to gather information about the temporal structure of the background and wire radiation. The line radiation in the spectra was recorded with wire currents at the few kA level. This is comparable to the first 10 ns of a 32-wire array experiment on 1 Ma generator and a 600-wire array at 20 MA.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Soldered Contact and Current Risetime Effects on Negative Polarity Wire Array Z-pinches

The Cornell University COBRA pulser is a nominal 1 MA machine, capable of driving up to 32 wire cylindrical Z-pinch arrays. COBRA can operate with variable current risetimes ranging from 100 ns to 200 ns (short and long pulse, respectively). Wires are typically strung with a 'press' contact to the electrode hardware, where the wire is loosely pulled against the hardware and held there to establish electrical contact. The machine is normally negative, but a bolt-on convolute can be used to modify the current path and effectively produce positive polarity operation at the load.Previous research with single wires on a 1-5 kA pulser has shown that soldering the wire, thereby improving the wire/electrode contact, and operating in positive polarity can improve the energy deposition into the wire and enhance wire core expansion. Negative polarity showed no difference. Previous experiments on the negative polarity, 20 MA, 100 ns Z accelerator have shown that improving the contact improved the x-ray yield.Cornell data were collected on 16-wire Aluminum Z-pinch arrays in negative polarity. Experiments were conducted with both short and long current pulses with soldered and no-soldered wire/electrode contacts. The initiation, ablation, implosion and stagnation phases were compared for these four conditions. Time dependent x-ray signals were measured using diodes and diamond detectors. An inductive voltage monitor was used to infer minimum current radius achieved, as defined by a uniform shell of current moving radially inward, producing a time dependent inductance. Total energy data were collected with a metal-strip bolometer. Self-emission data were collected by an XUV 4-frame camera and an optical streak camera.In negative polarity and with short pulses, soldering appeared to produce a smaller radius pinch and decrease variations in the x-ray pulse shape. The bolometer, laser backlighter, 4-frame and streak cameras showed negligible differences in the initiation ablation and implosion phases. X-ray yield was increased with soldered arrays in negative polarity with long pulses. The bolometer also showed a 50% increase in radial power emitted for soldered arrays. 4-frame images showed soldered arrays have a more pronounced 'Christmas Tree' effect originating from the cathode. The inductive voltage monitor showed, with both long and short pulses, that soldered and no-solder arrays reached the same minimum current radius at the same time. However, with long pulses soldered arrays radiate x-rays at the time of minimum current radius while no-solder array x-ray output is delayed by {approx}20 ns, resulting in decreased x-ray yield.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of the Axial Instability in Low Wire Number Wire Array Z-Pinches

We are investigating the development of the axial instability, a modulation of the size of the coronal plasma that develops around each wire in wire-array Z-pinches. The modulation is a result of nonuniform ablation of material from the relatively cold wire core. It has long been known that the wavelength of this modulation is constant late in time and, since it is unique to different materials, it has come to be known as the fundamental mode. In these experiments we imaged individual wires with laser shadowgraphy early in time primarily in low wire number, large wire diameter aluminum arrays for ease of viewing. We Observe the development of this modulation from the time of initiation of coronal plasma, obtaining its dominant wavelength and amplitude growth as a function of time. We also studied the instability on coiled wires, which modify the wire ablation mechanism and completely suppress the fundamental mode[Hall2008]. time is discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Analysis of Compact Cylindrical Wire Array Implosions with Brass and also by Alternating Brass and Al wires on the 1-MA COBRA Generator

Implosions from compact cylindrical wire arrays (CCWA) with mid-Z and low-Z wires were carried out on the 1-MA COBRA generator at Cornell University. In particular, the CCWA used either Brass 310 (70% Cu, 30% Zn) wires or a combination of Brass 310 and Al 5056 (95% Al, 5% Mg) wires arranged in an alternating pattern. A total of 16 wires were used on either a 6 or 4 mm diameter array. The diagnostic suite included a bolometer, fast x-ray detectors, a time-integrated spectrometer, and a streak camera. A higher energy output was observed from bolometer measurements when alternating the brass and Al wires compared to using only the brass wires. This study will focus mainly on the spectroscopy of the brass and alternating brass and Al CCWA by applying the non-LTE kinetic models of Cu and Zn to account for the L-shell radiation. The resulting plasma parameters, electron density and electron temperature, will be discussed and compared for the CCWA with only brass wires and alternating brass and Al wires. The simulations with the novel Wire Ablation Dynamics Model that account for wire ablation will be performed to analyze the differences in implosion dynamics of the uniform and alternating compact cylindrical arrays.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modifying Wire Array Z-pinch Ablation Structure and Implosion Dynamics Using Coiled Arrays

Coiled arrays, a cylindrical array in which each wire is formed into a helix, suppress the modulation of ablation at the fundamental wavelength. Outside the vicinity of the wire cores, ablation flow from coiled arrays is modulated at the coil wavelength and has a 2-stream structure in the r,{theta} plane. Within the vicinity of the helical wires, ablation is concentrated at positions with the greatest azimuthal displacement and plasma is axially transported from these positions such that the streams become aligned with sections of the coil furthest from the array axis. The GORGON MHD code accurately reproduces this observed ablation structure, which can be understood in terms of JxB forces that result from the interaction of the global magnetic field with a helical current path as well as additional current paths suggested by the simulations. With this ability to control where ablation streamers occur, large wavelength coils were constructed such that the breaks that form in the wires had sufficient axial separation to prevent perturbations in the implosion sheath from merging. This produces a new mode of implosion in which the global instability can be controlled and perturbations correlated between all wires in an array. For large wavelength 8-wire coiled arrays, this produced a dramatic increase in x-ray power, equalling that of a 32-wire straight array. These experiments were carried out on the MAGPIE generator (1 MA, 240 ns) at Imperial College, and the COBRA generator (1 MA, 100 ns) at Cornell University.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗