Performance degradation and cleaning of photovoltaic arrays

NASA tests results from an 18 mo program of cleaning silicone-encapsulated and glass fronted solar cell panels in urban and desert environments to examine the effects of cleaning on module performance are reported. The panels were cleaned on weekly, monthly, quarterly, or semi-annual basis, while other panels of the same construction were not cleaned and served as controls. Commercially-available detergents and city water were employed for the tests, and the measurements were maintained of the modules' continuing short-circuit current output. The decay of the output was determined by least square regression analyses. Performance degradation was noticeably less in glass covered, rather than silicone-encapsulated modules which decayed faster in urban than in desert environments. Lower frequency cleanings are recommended where labor costs are high.

Sheskin, T. J.↗

Evaluation of cleaners for photovoltaic modules exposed in an outdoor environment

Power recovery of silicone encapsulated and glass covered photovoltaic modules, exposed for two years to a suburban environment, was measured after washing with a variety of cleaners including detergents, abrasive soap, and hydrocarbon solvents. Silicone encapsulated modules in operating environments may experience significant power losses or require extensive periodic cleaning. Glass front-faced modules in similar situations are much less affected. Organic hydrocarbon solvents or abrasives were found to be about five times more effective than mild detergents in cleaning encapsulated modules.

Knapp, W. D.↗

Photovoltaic system test facility electromagnetic interference measurements

Field strength measurements on a single row of panels indicates that the operational mode of the array as configured presents no radiated EMI problems. Only one relatively significant frequency band near 200 kHz showed any degree of intensity (9 muV/m including a background level of 5 muV/m). The level was measured very near the array (at 20 ft distance) while Federal Communications Commission (FCC) regulations limit spurious emissions to 15 muV/m at 1,000 ft. No field strength readings could be obtained even at 35 ft distant.

Johnson, J. A.↗

ERDA/Lewis research center photovoltaic systems test facility

A national photovoltaic power systems test facility (of initial 10-kW peak power rating) is described. It consists of a solar array to generate electrical power, test-hardware for several alternate methods of power conversion, electrical energy storage systems, and an instrumentation and data acquisition system.

Forestieri, A. F.↗