Search NASA⌕ Search

Engineering topics

Knauer, J.

Publications and source records attributed to Knauer, J..

At least 19 records

Multi-X-point radiation and its dynamics in up/down asymmetry in plasma detachment regimes in Wendelstein 7-X

In Wendelstein 7-X (W7-X), stable plasma detachment in ECRH hydrogen plasmas is routinely achieved with the standard magnetic configuration, containing five magnetic islands in the scrape-off layer (SOL). Plasma detachment induced by intrinsic carbon impurities is characterized by a high radiation fraction (ƒ rad ) with significantly reduced divertor heat load and particle flux. In this work, we present the radiation dynamics during the detached plasma (DP) phase, such as the shift of radiation zones in radial and poloidal directions towards the X-points as ƒ rad increases (∼0.6–0.9), as well as the penetration of the radiation layer into the confinement region in the deep DP phase with ƒ rad approaching unity. In particular, a structure of multi-X-point radiation (multi-XPR) with an up/down asymmetry in the DP phase is highlighted, which is revealed by bolometer tomography and is further confirmed by video diagnostics. The multi-XPR structure forms helical 3D bands aligned with W7-X field periodicity. Field reversal experiments show that the brightest XPR displaces between the upper and lower SOL regions, suggesting the E× B drift effects. This paper presents the multi-XPR structure observed in the W7-X plasma in detail for the first time. A simplified model considering the influence of the poloidal E× B drift ( V d ) on the impurity flow in the SOL shows that the downstream drift toward the target or target shadow region ( V d < 0) decreases the impurity content, while the upstream drift toward the LCFS ( V d > 0) increases the impurity content. On this basis, the poloidal drift potentially leads to an up/down asymmetry of impurity density in the SOL despite the symmetry magnetic topology. The dynamics of the up/down asymmetry in the multi-XPR structure is also related to the magnitude V d /D (normalized to the impurity diffusivity), with an additional effect owing to the radial inward shift of the emission zone. These results provide new insights into impurity-induced detachment dynamics and provide a basis for improving 3D modeling of impurity transport, which typically does not consider drifts.

E × B drift↗

Improvements to the characterization of Agfa x-ray film for use on opacity spectroscopy diagnostics

The National Ignition Facility uses a soft x-ray opacity spectrometer for x-ray spectral imaging in high-energy-density experiments. The increased demand for a better spectral resolution prompted the investigation into the Agfa D4 film. Characterization is already under way for the film. A Manson x-ray source using six different anodes was used to expose film to the linear optical density (OD) region. This is a continuation of the previous work, and the updated analysis process is communicated here. The identified uncertainties have been reduced with the updated steps that improve the results of the characterization process. In conclusion, when the Stanford Synchrotron Radiation Lightsource Beamline 16-2 was operational, the film was characterized at that source. Its beam offered a higher fluency with a lower exposure time needed to reach saturation. Results for both sources are compared in this paper.

47 OTHER INSTRUMENTATION↗

Achieving stationary high performance plasmas at Wendelstein 7-X

This work reports on recent results on the search for high performance plasma scenarios at the magnetically confined stellarator fusion device Wendelstein 7-X. In four new designed scenarios, the development from transient toward stationary plasmas of improved performance has been realized. In particular, a high performance duration of up to 5 s, an energy confinement time of 0.3 s, a diamagnetic energy of 1.1 MJ, a central ion temperature of 2.2 keV, and a fusion triple product of 3.4 x 10 19 m -3 ∙ keV ∙ s have been achieved, and previously observed limitations of the machine have been overcome, regarding both the performance and its duration. The two main experimental techniques for stationary high performance are neutral beam injection core fueling on the one hand and the use of a magnetic field configuration with internal islands on the other hand. Two of the developed scenarios are expected to be extendable straightforward toward a duration of several tens of seconds, making use of the long pulse operation capabilities of W7-X.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Observation of impurity accumulation and its compatibility with high plasma performance in W7-X

At the W7-X stellarator, the bolometer system has measured an intensive radiation zone in the inner plasma region (at a normalized radius $ρ$ ~ 0.3–0.4) in the hydrogen plasma generated by electron cyclotron resonance heating; it differs from the normal plasma radiation distribution with an edge-localized emission zone. Spectroscopic diagnostics have recorded high-Z elements such as iron. This phenomenon happens in the plasma phases after gas supply turn-off, which results in all impurity relevant diagnostic signals increasing for several seconds. Despite the enhancement of the core radiation, the plasma energy confinement is improved. A transport analysis shows that this impurity radiation behavior is associated with a low diffusion coefficient ($D$~ 0.02 m 2 s -1 ) and a reversal of the convection around the radial position of the emission peak, which, under normal conditions, separates the zones of outward convection in the central (|$V$| ~ 0.1 m s -1 ) and inward convection in the outer region (|$V$| ~ 0.3 m s -1 ). An impurity accumulation around this radial position has been identified. The transport coefficients obtained are comparable with the theoretical predictions of collisional impurity transport. In the plasma phases studied, both impurity and energy confinement are enhanced. The mechanism responsible for the improvement is believed to be a reduction of micro-instabilities associated with the observed steepening of the density profile, initiated by a low edge plasma density (<1.0 × 10 19 m -3 ) after switching off the gas fueling. The normalized temperature and density gradients fulfil the condition for the suppression of ITG turbulence.

suppression of ITG turbulence↗

Effects of drifts on scrape-off layer transport in W7-X

Abstract Drifts affect particle, momentum, and energy transport in the scrape-off layer (SOL) of tokamaks and stellarators, altering plasma flows and creating asymmetries between divertors. To understand how drifts affect SOL transport in the W7-X island divertor, an experiment was performed to compare plasmas with matched core parameters but opposite magnetic field directions, and therefore opposite drift transport directions. Parallel flow measurements made with coherence imaging spectroscopy are interpreted with the aid of a diagnostic forward model and a 1D simple SOL model that includes the E × B drift. In low-density plasmas ( n ‾ e < 2 × 10 19 m −3 ), the poloidal E × B drift induces a large poloidal density asymmetry within the island SOL, as measured by divertor Langmuir probes. This in turn causes the parallel flow stagnation point to shift from the position halfway between targets to the X-point in the drift direction, leading to near-unidirectional flow throughout the SOL. As density increases, the effects of the poloidal E × B drift decrease substantially, resulting in a smaller density asymmetry and the development of a counter-streaming flow pattern. For the entire density range probed in this experiment ( n ‾ e = 1.5 − 6 × 10 19 m −3 ), the experimental observations are more consistent with the effects of the poloidal E × B drift than the radial E × B drift.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The phase-2 particle x-ray temporal diagnostic for simultaneous measurement of multiple x-ray and nuclear emission histories from OMEGA implosions (invited)

Electron-temperature (T e ) measurements in implosions provide valuable diagnostic information, as T e is negligibly affected by residual flows and other non-thermal effects unlike ion-temperature inferred from a fusion product spectrum. In OMEGA cryogenic implosions, measurement of T e (t) can be used to investigate effects related to time-resolved hot-spot energy balance. The newly implemented phase-2 Particle X-ray Temporal Diagnostic (PXTD) utilizes four fast-rise (~15 ps) scintillator-channels with distinct x-ray filtering. Titanium and stepped aluminum filtering were chosen to maximize detector sensitivity in the 10–20 keV range, as it has been shown that these x rays have similar density and temperature weighting to the emitted deuterium–tritium fusion neutrons (DTn) from OMEGA Cryo-DT implosions. High quality data have been collected from warm implosions at OMEGA. These data have been used to infer spatially integrated T e (t) with <10% uncertainty at peak emission. Nuclear and x-ray emission histories are measured with 10 ps relative timing uncertainty for x rays and DTn and 12 ps for x rays and deuterium- 3 He protons (D 3 Hep). A future upgrade to the system will enable spatially integrated T e (t) with 40 ps time-resolution from cryogenic DT implosions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

LLE Diagnostic Resource Team for Innovative Fusion Concepts (Final Report)

The LLE Diagnostic Resource Team for Innovative Fusion Concepts provided travelling neutron diagnostics, consultancy on neutron diagnostics, and consultancy on tritium handling to fusion companies. An existing neutron detector was recalibrated for low yields and two detectors were built based on designs proven on the Omega Laser Facility. The three detectors allow measurements over a wide range of yields (from 10 to 1E7 incident neutrons). The detectors were calibrated for DD neutrons on a dedicated OMEGA shot day. Neutron detectors from the company MIFTI were also calibrated on OMEGA. MIFTI is currently using their detectors and two of our detectors on staged Z-pinch experiments at UCSD. The Team acted as consultants for the development of a liquid scintillator array to detect neutrons from muon induced fusion by NK Labs. Segments of NK Labs’ detector were tested at the LLE using radioactive sources and a DD neutron generator. The Team also acted as consultants for the design of a tritium handling system for NK Labs. A new type of neutron spectrometer was designed and built, and has completed preliminary testing.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analysis of hydrogen fueling, recycling, and confinement at Wendelstein 7-X via a single-reservoir particle balance

Abstract A single-reservoir particle balance for the main plasma species hydrogen has been established for W7-X. This has enabled the quantitative characterization of the particle sources in the standard island divertor configuration for the first time. Findings from attached scenarios with two different island sizes with a boronized wall and turbo molecular pumping are presented. Fueling efficiencies, particle flows and source locations were measured and used to infer the total particle confinement time τ p . Perturbative gas injection experiments served to measure the effective particle confinement time τ p * . Combining both confinement times provides access to the global recycling coefficient R ¯ . Hydrogen particle inventories have been addressed and the knowledge of particle sources and sinks reveals the core fueling distribution and provides insight into the capability of the magnetic islands to control exhaust features. Measurements of hydrogen fueling efficiencies were sensitive to the precise fueling location and measured between 12% and 31% with the recycling fueling at the strike line modeled at only 6%, due to much higher densities. 15% of the total 5.2 × 10 22 a/s recycling flow ionizes far away from the recycling surfaces in the main chamber. It was shown that 60% of recycled particles ionize above the horizontal and 18% above the vertical divertor target, while the remainder of the recycling flow ionizes above the baffle (7%). Combining these source terms with their individual fueling efficiencies resolves the core fueling distribution. Due to the higher fueling efficiency in the main chamber, up to 51% of the total 5.1 × 10 21 s −1 core fueling particles are entering the confined plasma from the main chamber. τ p values in the range of 260 ms were extracted for these discharges. Together with τ p , the global recycling coefficient R ¯ was resolved for every τ p * measurement and a typical value close to unity was obtained. An increase of the island size, resulted in no change of τ p , but doubled τ p * , indicating the feasibility of the control coils as an actuator to control exhaust features without affecting core confinement properties.

recycling↗

Plasma radiation behavior approaching high-radiation scenarios in W7-X

The W7-X stellarator has so far performed experiments under both limiter and divertor conditions. The plasma is mostly generated by ECR-heating with powers up to 6.5 MW, and the plasma density is usually limited by the radiation losses from low-Z impurities (such as carbon and oxygen) released mainly from the graphite targets. The present work first summarizes the radiation loss fractions f rad achieved in quasi-stationary hydrogen plasmas in both operational phases, and then shows how impurity radiation behaves differently with the two different boundary conditions as the plasma density increases. The divertor operation is emphasized and some beneficial effects (with respect to impurity radiation) are highlighted: (1) intensive radiation is located at the edge (r/a > 0.8) even at high radiation loss fractions, (2) the plasma remains stable up to f rad approaching unity, (3) the reduction in the stored energy is about 10% for high f rad scenarios. Moreover, effects of wall boronisation on impurity radiation profiles are also presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

2D measurements of parallel counter-streaming flows in the W7-X scrape-off layer for attached and detached plasmas

Abstract Investigations of particle parallel flow velocities have been carried out for the scrape-off layer (SOL) of the Wendelstein 7-X (W7-X) stellarator, in order to gain insights on the SOL transport properties during attached and detached plasma scenarios. The experimental evidence is based on the coherence imaging spectroscopy (CIS) diagnostic, able to measure 2D impurity emission intensity and flow velocity. The impurity monitored by CIS is C 2+ , characterized by a line-emission intensity observed to be linearly proportional to the total plasma radiated power in both attached and detached plasmas. The related C 2+ velocity shows a strong dependence on the line-averaged electron density while remaining insensitive to the input power. During attached plasmas, the velocity increases with increasing line-averaged density. The tendency reverses in the transition to and during detachment, in which the velocity decreases by at least a factor of 2. The sharp drop in velocity, together with a rise in line-emission intensity, is reliably correlated to the detachment transition and can therefore be used as one of its signatures. The impurity flow velocity appears to be well coupled with the main ions’ one, thus implying the dominant role of impurity-main ion friction in the parallelimpurity transport dynamics. In view of this SOL impurity transport regime, the CIS measurement results are here interpreted with the help of EMC3-Eirene simulations, and their major trends are already explainable with a simple 1D fluid model.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Impurity transport in ion- and electron-root confinement scenarios at Wendelstein 7-X

This paper reports on the observation of enhanced Ar impurity confinement in high density, turbulence reduced ion-root confinement (IRC) scenarios in Wendelstein 7-X (W7-X). Compared to the central electron-root confinement (CERC), Ar densities are substantially increased up to one order of magnitude and Ar flux profiles switch from slightly positive to pronounced negative fluxes all along the plasma radius in IRC. Estimations of the diffusive D and convective V transport parameter profiles using the STRAHL impurity transport code suggest a fundamentally different behavior in CERC and IRC with, compared to neoclassical values, high diffusive D and typical V profiles in CERC versus strongly reduced D and pronounced negative V profiles in IRC.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-performance ECRH at W7-X: experience and perspectives

The second operation phase of W7-X (OP1.2) showed the potential of exclusively electron cyclotron resonance heating (ECRH)-sustained plasma operations in stellarators. Employing multi-pass ECRH scenario in the second harmonic O-mode (O2-ECRH), stationary densities of up to 1.4 × 10 20 m -3 could be achieved. This scenario also made stationary divertor detachment possible, which is a reactor-relevant scenario for power and particle exhaust. At high densities and with sufficiently high density gradients for an improved ion confinement, the coupling between the electrons and ions was strong enough to bring the ion temperature to values above 3 keV and to the neoclassical limit for some magnetic configurations, thus enabling to test the W7-X neoclassical optimization. The planned enhancement of the ECRH performance will enable to advance towards reactor-relevant beta values and to investigate their stability and confinement of fast particles, which is a priority goal of W7-X.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterization of injection and confinement improvement through impurity induced profile modifications on the Wendelstein 7-X stellarator

Pulsed injections of boron carbide granules into Wendelstein 7-X stellarator (W7-X) plasmas transiently increase the plasma stored energy and core ion temperatures above the reference W7-X experimental programs by up to 30%. In a series of 4 MW electron cyclotron resonance heating experiments, the PPPL Probe Mounted Powder Injector provided 50 ms bursts of 100 μm granules every 350 ms at estimated quantities ranging from approximately 1 mg/pulse to over 30 mg/pulse. For each injection, the stored energy was observed to initially drop and the radiated power transiently increased, while the radial electron density profile rose at the edge as material was assimilated. Once the injected boron carbide was fully absorbed, the density rise transitioned to the core while the stored energy increased above the previous baseline level by an amount linearly correlated with the injection quantity. During the injection, the ion temperature gradient steepened with peak core ion temperatures observed to increase from a nominal 1.7 keV to over 2.6 keV for the largest injection amounts. Enhanced performance is accompanied by a reversal of the radial electric field at ρ < 0.3, indicating that the core transport has switched to the ion root. These observations are suggestive of a change in transport and provide further evidence that externally induced profile modifications provide a possible path to enhanced W7-X performance metrics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterization of Agfa Structurix series D4 and D3sc x-ray films in the 0.7–4.6 keV energy range

X-ray films remain a key asset for high-resolution x-ray spectral imaging in high-energy-density experiments conducted at the National Ignition Facility (NIF). The soft x-ray Opacity Spectrometer (OpSpec) fielded at the NIF has an elliptically shaped crystal design that measures x rays in the 900–2100 eV range and currently uses an image plate as the detecting medium. However, Agfa D4 and D3sc x-ray films’ higher spatial resolution provides increased spectral resolution to the data over the IP-TR image plates, driving the desire for regular use of x-ray film as a detecting medium. The calibration of Agfa D4 x-ray film for use in the OpSpec is communicated here. These calibration efforts are vital to the accuracy of the NIF opacity measurements and are conducted in a previously un-studied x-ray energy range under a new film development protocol required by NIF. The absolute response of Agfa D4 x-ray film from 705 to 4620 eV has been measured using the Nevada National Security Site Manson x-ray source. A broader range of energies was selected to compare results with previously published data. The measurements were taken using selected anodes, filters, and applied voltages to produce well-defined energy lines.

Dutra, E. C. (ORCID:0000000167649195)↗

Understanding detachment of the W7-X island divertor

The fundamental behavior of the W7-X island divertor under detached conditions, which has been theoretically predicted with the EMC3-Eirene code, is re-examined here under the experimental conditions achieved so far and compared with the first experimental results. Both simulations and experiments cover a range of divertor configurations and plasma parameters, and show the following common trends: (1) with rising impurity radiation, the target heat load decreases 'uniformly' over the entire target surface in the sense that both the peak and average heat loads can drop by an order of magnitude. Impurity radiation (mainly from intrinsic carbon) occurs primarily at the plasma edge and the resulting negative impact on the stored energy is less than 10%. (2) When the total radiation exceeds a critical level, the target particle flux (the recycling flux Γrecy) begins to fall and can drop by a factor of 3–5 at high radiation levels without an obvious indication of significant volume recombination. (3) While Γ recy decreases, the divertor neutral pressure continues to build up and reaches a maximum, at which point Γ recy has declined significantly. (4) During detachment, the electron temperature at the last closed flux surface falls in a way that is not quantitatively understandable from parallel classical heat conduction processes. This paper presents a physical explanation of the numerical/experimental results described above. Furthermore, using the EMC3-Eirene code as a diagnostic tool, we are able, apparently for the first time, to provide a full quantitative analysis of each transport channel in the island divertor, aiming to clarify how the island divertor plasma self-regulates to maintain particle, energy, and momentum balance under detached conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A multi-channel x-ray temporal diagnostic for measurement of time-resolved electron temperature in cryogenic deuterium–tritium implosions at OMEGA

Electron-temperature (T e ) measurements in implosions provide valuable diagnostic information, as Te is unaffected by residual flows and other non-thermal effects unlike ion temperature inferred from a fusion product spectrum. In OMEGA cryogenic implosions, measurement of T e (t) can be used to investigate effects related to time-resolved hot-spot energy balance. The proposed diagnostic utilizes five fast-rise (~15 ps) scintillator channels with distinct x-ray filtering. Furthermore, titanium and stepped aluminum filtering were chosen to maximize detector sensitivity in the 10 keV–20 keV range, as it has been shown that these x rays have similar density and temperature weighting to the emitted deuterium–tritium fusion neutrons. Initial data collected using a prototype nosecone on the existing neutron temporal diagnostic demonstrate the validity of this diagnostic technique. The proposed system will be capable of measuring spatially integrated T e (t) with 20 ps time resolution and <10% uncertainty at peak emission in cryogenic DT implosions.

47 OTHER INSTRUMENTATION↗

Direct and seasonal legacy effects of the 2018 heat wave and drought on European ecosystem productivity

In summer 2018, central and northern Europe were stricken by extreme drought and heat (DH2018). The DH2018 differed from previous events in being preceded by extreme spring warming and brightening, but moderate rainfall deficits, yet registering the fastest transition between wet winter conditions and extreme summer drought. Using 11 vegetation models, we show that spring conditions promoted increased vegetation growth, which, in turn, contributed to fast soil moisture depletion, amplifying the summer drought. We find regional asymmetries in summer ecosystem carbon fluxes: increased (reduced) sink in the northern (southern) areas affected by drought. These asymmetries can be explained by distinct legacy effects of spring growth and of water-use efficiency dynamics mediated by vegetation composition, rather than by distinct ecosystem responses to summer heat/drought. The asymmetries in carbon and water exchanges during spring and summer 2018 suggest that future land-management strategies could influence patterns of summer heat waves and droughts under long-term warming.

54 ENVIRONMENTAL SCIENCES↗