National transonic facility Mach number system

The Mach number system for the Langley Research Center's National Transonic Facility was designed to measure pressures to determine Mach number to within + or - 0.002. Nine calibration laboratory type fused quartz gages, four different range gages for the total pressure measurement, and five different range gages for the static pressure measurement were used to satisfy the accuracy requirement over the 103,000-890,000 Pa total pressure range of the tunnel. The system which has been in operation for over 1 year is controlled by a programmable data process controller to select, through the operation of solenoid valves, the proper range fused quartz gage to maximize the measurement accuracy. The pressure gage's analog outputs are digitized by the process controller and transmitted to the main computer for Mach number computation. An automatic two-point on-line calibration of the nine quartz gages is provided using a high accuracy mercury manometer.

Kern, F. A.↗

Camera add-on records time of exposure

Time photograph is taken and is permanently recorded on edge of exposure by compact electronics module that attaches to camera case. Single-chip timing circuit drives LED display, which is imaged on film plane. Normally blanked display is unblanked when shutter switch is activated.