Pioneer Venus observations of plasma and field structure in the near wake of Venus

Ionospheric plasma density depletions or 'holes' are observed by the Pioneer Venus orbiter in association with radial magnetic fields in the near wake of Venus. This report presents examples of the collected observations of these unexpected features of the Venus nightside ionosphere obtained by the Langmuir probe, magnetometer, ion mass spectrometer, retarding potential analyzer, plasma analyzer, and electric field experiments. The connection between plasma density depletions and temperature changes, changes in ion composition, plasma wave emissions, and magnetic fields with a substantial radial component is illustrated. Mechanisms that may be responsible for the formation and maintenance of holes are suggested.

Luhmann, J. G.↗

The Venus ionosphere at grazing incidence of solar radiation - Transport of plasma to the night ionosphere

A quasi-two-dimensional model of the Venusian ionosphere is used to calculate the ion number densities and horizontal ion bulk velocities expected for a range of solar zenith angles near the terminator (80-100 deg). These results are compared with data from the Pioneer Venus Orbiter retarding potential analyzer. It is shown that antisunward horizontal plasma fluxes produced by solar EUV-induced pressure gradients are sufficient to maintain the nighttime ionosphere. While photoionization is the dominant source of ionospheric plasma for solar zenith angles less than 92 deg, plasma transport from the dayside is the dominant plasma source for solar zenith angles greater than 95 deg. It is also shown that the main nightside plasma peak at a height of 140 km is of the F2 type; its height and shape are therefore quite insensitive to the height of the ion source.

Whitten, R. C.↗

A new concept of plasma motion and planetary magenetic field for Venus

It is shown that the magnetohydrodynamic conditions of the Venus ionosphere near the terminator favor convection of a magnetic field rather than diffusion. Consequently, any planetary magnetic field which Venus may possess will be strongly affected by the global antisunward flow of the ionosphere which has been revealed by the Pioneer-Venus retarding potential analyzer. The magnetic flux from an internal magnetic field will accumulate in the night hemisphere. Details of the structure and dynamics of such accumulations depend on particular details of the magnetic field source and the time-dependent plasma flow pattern, but a simple interpretation of observational data yields a magnetic dipole moment of 7 x 10 to the 20th cu cm directed along the planet spin vector.

Knudsen, W. C.↗

Improved Venus ionopause altitude calculation and comparison with measurement

Improved approximations are incorporated into the inviscid fluid method originated by Spreiter et al (1970) in calculations of the altitude of the Venus ionopause. The altitude calculations are then compared with median altitudes measured by the Pioneer Venus retarding potential analyzer. The calculated ionopause shape is found to closely approximate the measured meridian shape in the solar zenith angle (SZA) range of zero-135 deg. The use of improved ionospheric pressure field ionosheath pressure and Prandtl-Meyer expansion approximations lowers the terminator ionopause altitude to approximately half that obtained with the usual Spreiter approximations. It is also determined that the calculated dawn ionopause is about 300 km higher than the dusk ionopause, and that both ionopauses are close to their respective measured meridian values. It is concluded that median ionopause altitude within the SZA angle range may be calculated without inclusion of a viscous interaction in the theory.

Knudsen, W. C.↗

On the maintenance of the Venus nightside ionosphere - Electron precipitation and plasma transport

The relative contributions of electron precipitation and transport of dayside plasma to the maintenance of the Venus nightside ionosphere during the long Venusian night are investigated based on simultaneous Pioneer Venus Orbiter Retarding Potential Analyzer measurements of suprathermal electron fluxes and plasma densities. In about 20 orbits, the nightside integral electron flux of electrons with energies between 5 and 45 eV is observed to be relatively constant in time and altitude, while plasma density is observed to vary by a factor of 10 or more with no correlation with the electron flux. Ionization rates and ion density height profiles are computed for O(+) and O2(+) as a function of magnetic dip angle based on a typical electron spectrum, or a downward flux of O(+) ions. Comparison of the computed profiles with the measured median O(+) and O2(+) density profiles reveals that the measured profiles can only be reproduced by a downward flux of O(+) equal to about 10 to the 8th/sq cm per sec; suprathermal electron energy distributions produce O2(+) and O(+) levels only about half and one tenth those usually observed, respectively. It is thus concluded that transport of O(+) ions from the dayside Venus ionosphere is responsible for approximately 75% of the typical nightside ionization, with variations in O(+) transport mechanism responsible for most of the observed nightside density variations. The remaining ionization is attributed to suprathermal electrons, which contribute principally to the O2(+) peak.

Spenner, K.↗

Anti-solar acceleration of ionospheric plasma across the Venus terminator

It is demonstrated that the horizontal ionospheric particle pressure gradient across the Venus terminator is the principal body force accelerating the plasm to the observed anti-solar velocity. The large scale horizontal electromagnetic body force is typically an order of magnitude smaller than the particle pressure gradient. The viscous body forces above 300 km - drag or acceleration - are also an order of magnitude smaller than the pressure gradient body force. In the immediate vicinity of the ionopause where the ionospheric plasma density decreases below 1000 ions/cu cm and the magnetic field strength increases, the electromagnetic body force may become significant. The electromagnetic body force may also be significant in the nightside ionosphere. The bulk of the ionospheric flow momentum is not derived from the ionosheath momentum.

Knudsen, W. C.↗

Observation of the Venus mantle, the boundary region between solar wind and ionosphere

For three orbit paths of the Pioneer Venus orbiter the interaction between the solar wind and the Venusian ionosphere has been studied. Results of the retarding potential analyzer and the magnetometer are described for the boundary region between the solar wind and the planetary ionosphere. These are the first measurements that show that a transition region exists between the two plasmas of different origin. The observed magnetic field and current system producing it appear strong enough to stop the solar wind flow in front of the ionosphere and to separate the shocked solar wind from the ionosphere. The transition region between the ionosheath and the ionosphere is called the 'mantle'. The observed mantle electron energy spectra close to the ionopause show ionospheric character. With increasing height the number of electrons that have ionospheric energies decreases, and the number of electrons that have solar wind energies gradually increases toward the ionosheath boundary, where only solar wind energy spectra are observed. The mantle surrounds the frontside of the ionosphere and extends probably more than eight Venus radii downstream.

Spenner, K.↗

Suprathermal electron energy distribution within the dayside Venus ionosphere

The suprathermal electron energy distribution for the dayside ionosphere has been derived from data returned by the Pioneer-Venus orbiter retarding potential analyzer. The shape and magnitude of the spectrum are consistent with the assumption that solar EUV radiation is the only significant source. The magnitude of the spectrum and its variation with altitude suggest that significant vertical transport occurs, with the electrons being lost through the ionopause. In turn, significant vertical transport suggests that the effective vertical electron heat conductivity may be comparable to the field-free value. The heat input to the thermal electron gas from the measured suprathermal electron flux is too small by a factor of at least five to maintain the observed electron temperature profile if the electron thermal conductivity is assumed to be close to the field-free value. It is thus inferred that most of the heat is supplied by the solar wind.

Knudsen, W. C.↗

Solar zenith angle dependence of ionospheric ion and electron temperatures and density on Venus

The measurements taken during the first year of the Pioneer Venus orbiter retarding potential analyzer indicate the changes of ion and electron temperatures with solar zenith angles. The ion density decreases by an order of magnitude from dayside to nightside; median ion temperatures above 300 km are constant with the solar zenith angle below 150 deg and reach 2300 K at the ionopause. The ion temperatures below 300 km are almost constant with solar zenith angles during the dayside, but increase with the angles on the nightside. The electron temperatures suggest a constant heat flux into the electron gas at the ionopause which may be supplied by dissipation of energy by the whistler mode plasma waves at the ionopause and/or conduction of heat from the ionosheath through the mantle.

Miller, K. L.↗

Model calculations of the dayside ionosphere of Venus - Energetics

A model of the energy balance of the dayside ionosphere of Venus is presented. Calculations of the dayside electron and ion temperature profiles are carried out and compared with data from experiments on the Pioneer Venus orbiter. The coupled heat conduction equations for electrons and ions are solved for several values of the solar zenith angle. It is shown that thermal conductivities are inhibited by the presence of a horizontal magnetic field. A realistic model of the magnetic field that includes fluctuations is employed in deriving an appropriate expression for the thermal conductivity. The contributions of photoelectrons, ion chemistry, Joule heating, and solar wind heating to the energy balance of the ionosphere are considered.

Cravens, T. E.↗

Transport of ionospheric O/+/ ions across the Venus terminator and implications

Data from the Pioneer Venus orbiter retarding potential analyzer demonstrate that the velocity of ionospheric O(+) ions in the vicinity of the terminator is directed antisunward and radially inward toward the planet in the range of 1-8 km/s. The velocity tends to increase with altitude, and may increase to still larger values just below the ionopause. The Alfven Mach number of the flow is generally greater than 1, indicating that the flow is controlled more by inertial forces than by magnetic forces. The ion Mach number is also greater than one. The flux of O(+) ions across the terminator planetwise is estimated to be equal to the integrated recombination rate of O2(+) on the night side within a factor of 2. Ion transport contributes substantially, and possibly predominantly, to the maintenance of the night side ionosphere.

Knudsen, W. C.↗

Ion energetics in the Venus nightside ionosphere

Consideration is given to the energetics of the ion gas flowing across the terminator into the Venus nightside ionosphere. Expressions are derived for the transport time of the ion gas (through 1 radian in solar zenith angle), the heat transfer time from the hot electron gas to the ions of an amount equal to the ion thermal energy), and the time required for vertical heat conduction to remove the internal energy of the ion column above a reference altitude, and it is shown that the time constant for transport is an order of magnitude smaller than the electron heat transfer time and comparable to the conduction time, and thus the ion gas is not a vertical conductive steady state. The conversion of bulk flow ion kinetic energy into heat is suggested as the mechanism responsible for the maintenance of the nightside ion temperatures at their observed values. It is thus concluded that the flow of the ion gas is quasi-adiabatic, and that steady-state, vertical, one dimensional energy balance models must be used with caution in the Venus ionosphere.

Knudsen, W. C.↗

Simple models of the thermal structure of the Venusian ionosphere

Analytical and numerical models of plasma temperatures in the Venusian ionosphere are proposed. The magnitudes of plasma thermal parameters are calculated using thermal-structure data obtained by the Pioneer Venus Orbiter. The simple models are found to be in good agreement with the more detailed models of thermal balance. Daytime and nighttime temperature data along with corresponding temperature profiles are provided.

Whitten, R. C.↗

Pioneer Venus Orbiter planar retarding potential analyzer plasma experiment

The retarding potential analyzer (RPA) on the Pioneer Venus Orbiter Mission measures most of the thermal plasma parameters within and near the Venusian ionosphere. Parameters include total ion concentration, concentrations of the more abundant ions, ion temperatures, ion drift velocity, electron temperature, and low-energy (0-50 eV) electron distribution function. Several functions not previously used in RPA's were developed and incorporated into this instrument to accomplish these measurements on a spinning spacecraft with a small bit rate. The more significant functions include automatic electrometer ranging with background current compensation; digital, quadratic retarding potential step generation for the ion and low-energy electron scans; a current sampling interval of 2 ms throughout all scans; digital logic inflection point detection and data selection; and automatic ram direction detection.

Knudsen, W. C.↗

Thermal structure and energy influx to the day- and nightside Venus ionosphere

The thermal structure of and energy influx to the dayside and nightside Venus ionosphere are discussed, based on data obtained by the Pioneer Venus spacecraft. Where the dayside ionosphere appears relatively constant in total ion concentration, ion and electron temperatures and ion composition below the ionopause, retarding potential analyzer measurements confirm the presence of strong spatial and temporal variations in nightside ion concentration. Ion temperatures on the nightside above 225 km are found to be larger by a factor of two or more than on the dayside, and comparable to electron temperatures on the day and night sides. Models of dayside and nightside ion temperatures consistent with observations require the heat input of 0.003 erg/sq cm sec and 0.005 erg/sq cm sec, respectively, to the ion gas to raise the ion temperature above that of the neutral gas, presumably by means of Joule heating.

Knudsen, W. C.↗

The energetics of the ionosphere of Venus - A preliminary model based on Pioneer Venus observations

A model of the energy balance of the dayside ionosphere of Venus is presented. The coupled energy equations for electrons and ions are solved numerically and the calculated temperatures are compared with temperatures measured by instruments on the Pioneer Venus Orbiter. Neutral and ion density profiles consistent with those measured by various Pioneer Venus experiments are used in the model. It was found that using standard EUV sources and thermal conductivities the calculations produce temperatures that are much lower than the measured ones. Consequently, further calculations were performed in which (1) the thermal conductivities were inhibited by means of an almost horizontal magnetic field and/or (2) heat inflow into both the electron and ion gas at the top of the ionosphere was assumed due to the solar wind interaction. It was found that the calculated and measured temperatures were in reasonably good agreement if the thermal conductivities were inhibited by a near horizontal field of about 10 gammas and if the electron and ion heat fluxes were taken to be 4 x 10 to the 9th eV/sq cm/sec and 10 to the 7th eV/sq cm/sec, respectively.

Cravens, T. E.↗

Retarding potential analyzer for the Pioneer-Venus Orbiter Mission

The retarding potential analyzer on the Pioneer-Venus Orbiter Mission has been designed to measure most of the thermal plasma parameters within and near the Venusian ionosphere. Parameters include total ion concentration, concentrations of the more abundant ions, ion temperatures, ion drift velocity, electron temperature, and low-energy (0-50 eV) electron distribution function. To accomplish these measurements on a spinning vehicle with a small telemetry bit rate, several functions, including decision functions not previously used in RPA's, have been developed and incorporated into this instrument. The more significant functions include automatic electrometer ranging with background current compensation; digital, quadratic retarding potential step generation for the ion and low-energy electron scans; a current sampling interval of 2 ms throughout all scans; digital logic inflection point detection and data selection; and automatic ram direction detection. Extensive numerical simulation and plasma chamber tests have been conducted to verify adequacy of the design for the Pioneer Mission.

Knudsen, W. C.↗

Thermal structure and major ion composition of the Venus ionosphere - First RPA results from Venus orbiter

Pioneer Venus in situ measurements of thermal plasma quantities were obtained by a retarding potential analyzer. Evidence for significant solar wind heating of the ionosphere and indications that the ionosphere is close to diffusive equilibrium are reported. Information on ionopause height, the ionospheric particle pressures at the ionopause, and the measured ratio of ionospheric scale height to ionopause ratio is presented.

Knudsen, W. C.↗