From zonal to nodal capacity expansion planning: Spatial aggregation impacts on a realistic test-case
Explore the source record for details and available documents.
Engineering topics
Publications and source records attributed to Knueven, Ben.
Explore the source record for details and available documents.
The presentation highlights the market analysis capabilities, both price-taker analysis and the novel market surrogate models approach, applied to optimal design of electricity and hydrogen co-production systems. The research findings were presented at the 2023 AIChE Annual Meeting.
Low-salt-rejection reverse osmosis (LSRRO) is an emerging membrane-based desalination technology for concentrating brines with potentially lower energy consumption and cost than thermally driven processes. We assess the technoeconomic performance of LSRRO by using an optimization model that minimizes the levelized cost of water (LCOW). We develop detailed models for the RO module and other equipment using WaterTAP (Water treatment Technoeconomic Assessment Platform), an open-source simulation and optimization software for water treatment. We improve upon previous LSRRO cost optimization studies by optimizing the salt permeability for each stage, which has significant implications for technoeconomic performance. We present the cost-optimal design, operation, and performance for three cases: 35 g/L TDS feed at 70% recovery, 70 g/L at 55%, and 125 g/L at 35%. The cost-optimal LCOW and specific energy consumption (SEC) for these cases are 0.70, 1.89, and 7.41 $/m 3 and 3.9, 8.4, and 30.4 kWh/m 3 , respectively. For each case, we use sensitivity analyses to provide guidance on key factors that impact economic viability. We also present the cost-optimal LCOW and SEC for feed concentrations between 5 and 220 g/L TDS and recoveries between 30 and 90%. So, we compare LSRRO to other high-salinity desalination technologies and find that it may be cost-competitive below feed concentrations of 125 g/L.
The presentation was delivered at the 2022 American Institute of Chemical Engineers (AIChE) annual meeting.
As Integrated Energy Systems (IES) combine multiple energy and storage technologies to provide potentially more value and less risk via resource diversification, complementary overbuild, increased flexibility, and revenue-stacking, IES value is dependent on electricity market dispatch and grid interactions should play an important role in IES design and operation. This study hybridizes and retrofits wind and combustion turbine plants to study the impacts of replacing gas generation capacity with wind, battery, PEM electrolysis, hydrogen tanks and hydrogen turbines. The optimized design is co-simulated in a production cost model with different bidding strategies in order to compare performance and highlight the importance of grid-interactions. We analyze the revenue and dispatch changes as well as the price and cost implications of wind-battery-hydrogen IESs.
Abstract not provided.
Distributed energy resources (DER) in distribution systems, including renewable generation, micro-turbine, and energy storage, can be used to restore critical loads following extreme events to increase grid resiliency. However, properly coordinating multiple DERs in the system for multi-step restoration process under renewable uncertainty and fuel availability is a complicated sequential optimal control problem. Due to its capability to handle system non-linearity and uncertainty, reinforcement learning (RL) stands out as a potentially powerful candidate in solving complex sequential control problems. Moreover, the offline training of RL provides excellent action readiness during online operation, making it suitable to problems such as load restoration, where in-time, correct and coordinated actions are needed. In this study, a distribution system prioritized load restoration based on a simplified single-bus system is studied: with imperfect renewable generation forecast, the performance of an RL controller is compared with that of a deterministic model predictive control (MPC). Our experiment results show that the RL controller is able to learn from experience, adapt to the imperfect forecast information and provide a more reliable restoration process when compared with the baseline MPC controller.
WaterTAP is a new open source library of water-specific models built on the IDAES Integrated Platform to support the design and optimization of integrated water treatment systems, improve existing systems and enable the analysis of new designs incorporating emerging technologies. WaterTAP enables advanced modeling and optimization for: conceptual and multiscale design, dynamics and model predictive control of water systems and networks.
Abstract not provided.
Abstract not provided.
We present a perfect formulation for a single generator in the unit commitment problem, inspired by the dynamic programming approach taken by Frangioni and Gentile. This generator can have characteristics such as ramp-up/ramp-down constraints, time-dependent start-up costs, and start-up/shut-down limits. To develop this perfect formulation, we extend the result of Balas on unions of polyhedra to present a framework allowing for flexible combinations of polyhedra using indicator variables. Here, we use this perfect formulation to create a cut-generating linear program, similar in spirit to lift-and-project cuts, and demonstrate computational efficacy of these cuts in a utility-scale unit commitment problem.
Here, we present sufficient conditions under which thermal generators can be aggregated in mixed-integer linear programming (MILP) formulations of the unit commitment (UC) problem, while maintaining feasibility and optimality for the original disaggregated problem. Aggregating thermal generators with identical characteristics (e.g., minimum/maximum power output, minimum up/down-time, and cost curves) into a single unit reduces redundancy in the search space induced by both exact symmetry (permutations of generator schedules) and certain classes of mutually non-dominated solutions. We study the impact of aggregation on two large-scale UC instances, one from the academic literature and another based on real-world operator data. Our computational tests demonstrate that when present, identical generators can negatively affect the performance of modern MILP solvers on UC formulations. Further, we show that our reformation of the UC MILP through aggregation is an effective method for mitigating this source of computational difficulty.