Search NASA⌕ Search

Engineering topics

Koch, L.

Publications and source records attributed to Koch, L..

Introducing a Markov chain-based time calibration procedure for multi-channel particle detectors: application to the SuperFGD and ToF detectors of the T2K experiment

Inter-channel mis-synchronisation can be a limiting factor to the time resolution of high performance timing detectors with multiple readout channels and independent electronics units. In these systems, time calibration methods employed must be able to efficiently correct for minimal mis-synchronisation between channels and achieve the best detector performance. We present an iterative time calibration method based on Markov Chains, suitable for detector systems with multiple readout channels. Starting from correlated hit pairs alone, and without requiring an external reference time measurement, the method solves for fixed per-channel offsets, with precision limited only by the intrinsic single-channel resolution. A mathematical proof that the method is able to find the correct time offsets to be assigned to each detector channel in order to achieve inter-channel synchronisation is given, and it is shown that the number of iterations to reach convergence within the desired precision is controllable with a single parameter. Numerical studies are used to confirm unbiased recovery of true offsets. Finally, the application of the calibration method to the Super Fine-Grained Detector (SuperFGD) and the Time of Flight (TOF) detector at the upgraded T2K near detector (ND280) shows good improvement in overall timing resolution, demonstrating the effectiveness in a real-world scenario and scalability.

calibration and fitting methods↗

Characterization of a radiation detector based on opaque water-based liquid scintillator

Here, we present the characterization of a novel radiation detector based on an opaque water-based liquid scintillator. Opaque scintillators, also known as LiquidO, are made to be highly scattering, such that the scintillation light is effectively confined, and read out through wavelength-shifting fibers. The 1-liter, 32-channel prototype demonstrates the capability for both spectroscopy and topological reconstruction of point-like events. The design, construction, and evaluation of the detector are described, including modeling of the scintillation liquid optical properties and the detector’s response to gamma rays of several energies. A mean position reconstruction error of 4.4 mm for 1.6 MeV-equivalent events and 7.4 mm for 0.8 MeV-equivalent events is demonstrated using a simple reconstruction approach analogous to center-of-mass.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Spectral observation of the soft X-ray background and of the North Polar Spur with solid state spectrometers

Soft X-ray diffuse background observations in the 0.3-1.5 keV interval of two sky regions, near the north galactic pole and the North Polar Spur (NPS) are reported. Data were taken with a solid-state spectrometer carried by a rocket. The near-polar region exhibited O VII ion emissions at 530 eV. A second component was not identified but was attributed to the Galactic Halo. Fe XVIII, Ne IX, and O VIII contributions were detected in the NPS, along with an enhancement at 1.35 keV from Mg XI lines. A two-temperature contour was fit to the spectra and chi-square confidence levels of 90 and 68 percent were obtained.

Rocchia, R.↗

The HEAO-3 Cosmic Ray Isotope spectrometer

This paper describes the Cosmic Ray Isotope instrument launched aboard the HEAO-3 satellite on September 20, 1979. The primary purpose of the experiment is to measure the isotopic composition of cosmic ray nuclei from Be-7 to Fe-58 over the energy range 0.5 to 7 GeV/nucleon. In addition charge spectra will be measured between beryllium and tin over the energy range 0.5 to 25 GeV/nucleon. The charge and isotope abundances measured by the experiment provide essential information needed to further our understanding of the origin and propagation of high energy cosmic rays. The instrument consists of 5 Cerenkov counters, a 4 element neon flash tube hodoscope and a time-of-flight system. The determination of charge and energy for each particle is based on the multiple Cerenkov technique and the mass determination will be based upon a statistical analysis of particle trajectories in the geomagnetic field.

Bouffard, M.↗

Carbon and oxygen X-ray line emission from the interstellar medium

A soft X-ray, 0.3-1.0 keV spectrum from a 1 sr region which includes a portion of the North Polar Spur, obtained by three rocketborne lithium-drifted silicon detectors, shows the C V, C VI, O VII and O VIII emission lines. The spectrum is well fitted by a two-component, modified Kato (1976) model, where the coronal emission is in collisional equilibrium, with interstellar medium and North Polar Spur temperatures of 1.1 and 3.8 million K, respectively.

Schnopper, H. W.↗

First detection of line emission from the hot interstellar medium with solid state detectors

Previously reported enhanced soft X-ray emission from the North-Galactic Polar region supports the theory of a hot interstellar component. This paper reports the first detection of line emission from the hot interstellar component in the North-Galactic-Polar region. Measurements were made with solid state Si(Li) detectors aboard a spin-stabilized rocket launched from the White Sands Missile Range on March 22, 1980. Two features are clearly present in the low energy portion of the spectrum derived from the data. They correspond to emission lines from C V (300 eV) and C VI (360 eV), and from O VII (560 eV) and O VIII (650 eV). The detection of emission lines coming from these highly stripped ions is direct evidence for the thermal origin of the emission and confirms the presence of a hot (1-million K) component in the interstellar medium.

Schnopper, H. W.↗

Properties of a silica aerogel Cerenkov radiator used in a cosmic ray telescope

A silica aerogel Cerenkov radiator with a refractive index of 1.06 has been flown in a balloon borne cosmic ray telescope. Clear separation of the elements in the iron group was achieved even at high energies. No detectable scintillation component was found. Some optical properties of the silica aerogel used in this flight are presented.

Cantin, M.↗