Search NASA⌕ Search

Engineering topics

Koehler, Paul E.

Publications and source records attributed to Koehler, Paul E..

At least 19 records

Study of 149 Sm Capture and Total Cross Sections for Burnup Credit Applications [Slides]

This presentation highlights how capture and transmission measurements were performed with the DANCE (Detector for Advanced Neutron Capture Experiments) instrument with capture data from 8 eV – 1 keV, and DICER (Device for Indirect Capture Experiments on Radionuclides) instruments with transmission data from 1meV – 1 keV. There were additional measurements of 147 Sm which had contaminant in the samples, 3.4 eV strong resonance, interesting abnormalities. The data analysis is complete and the R-Matrix analysis almost (90%) complete.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The LANSCE experimental program: accelerator requirements

The LANSCE accelerator complex exploits a flexible, high power 800 MeV proton linear accelerator to enable a broad swath of experimental work supporting multiple scientific programs. The beam requirements for these programs are diverse and change over time. The purpose of this document is to record, at a high level, the experimental requirements driving the beam delivery requirements for each experimental facility at LANSCE. Revision 0 serves to baseline the current set of experiments, and we expect to revise the document on an as-needed basis when either the experimental requirements change or are found to require a more complete definition.

43 PARTICLE ACCELERATORS↗

Production of zirconium-88 via proton irradiation of metallic yttrium and preparation of target for neutron transmission measurements at DICER

Abstract A process for the production of tens to hundreds of GBq amounts of zirconium-88 ( 88 Zr) using proton beams on yttrium was developed. For this purpose, yttrium metal targets (≈20 g) were irradiated in a ~16 to 34 MeV proton beam at a beam current of 100–200 µA at the Los Alamos Isotope Production Facility (IPF). The 88 Zr radionuclide was produced and separated from the yttrium targets using hydroxamate resin with an elution yield of 94(5)% (1σ). Liquid DCl solution in D 2 O was selected as a suitable 88 Zr sample matrix due to the high neutron transmission of deuterium compared to hydrogen and an even distribution of 88 Zr in the sample matrix. The separated 88 Zr was dissolved in DCl and 8 µL of the obtained solution was transferred to a tungsten sample can with a 1.2 mm diameter hole using a syringe and automated filling station inside a hot cell. Neutron transmission of the obtained 88 Zr sample was measured at the Device for Indirect Capture Experiments on Radionuclides (DICER).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Constraining the nuclear spin distribution using improved 197 Au neutron resonance parameters

New neutron transmission data at resonance energies using a 197 Au sample were measured using an early version of the Device for Indirect Capture Experiments on Radionuclides (DICER), which is under development at the Los Alamos Neutron Science Center (LANSCE). These data were combined with previous neutron transmission and capture data in a simultaneous R-matrix analysis to extract improved neutron resonance parameters for this nuclide. As a result, total radiation widths, Γ γ , were obtained for 33 J=1 and 44 J=2 197 Au+n resonances. Γ γ distributions for these two spins states were compared to distributions calculated according to the nuclear statistical model using published nuclear level density (NLD) and photon strength functions (PSF) measured using the Oslo technique. The calculated distributions were found to be narrower and the average values for the two spins states closer together than the data. The calculation can be brought into agreement with the data by substantial modifications to the spin distribution in 198 Au as a function of excitation energy. As far as we know, the spin distribution currently is otherwise poorly constrained. The modified spin distribution changes the shapes of the NLD and PSF extracted using the Oslo technique and so could have broad implications.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Improved $^{95}\mathrm{Mo}$ neutron resonance parameters and astrophysical reaction rates

We report improved 95 Mo neutron resonance parameters and reaction rates are important for nuclear astrophysics, testing nuclear models, and nuclear criticality safety. However, despite many previous neutron-capture and total cross-section measurements on this nuclide, there still is much room for improvement as well as several discrepancies. For example, there are very few firm resonance spin and parity assignments; average resonance parameters are available only for each parity, the currently recommended astrophysical reaction rate results in disagreements between stellar models and meteoric isotopic anomalies, and there are substantial disagreements in the neutron-capture cross section at low energies important for nuclear criticality safety. To obtain an improved set of neutron resonance parameters and astrophysical reaction rates for 95 Mo. High-resolution neutron-capture and transmission data were measured at the Oak Ridge Electron Linear Accelerator (ORELA) using highly isotopically enriched 95 Mo samples. The neutron-capture apparatus, data reduction, and analysis were improved so that information contained in the γ-ray cascade following neutron capture were used to assign resonance J π values. Following this, simultaneous analysis of the new neutron-capture and transmission data was used to obtain resonance energies, gamma widths, and neutron widths and their uncertainties to a maximum energy of 10 keV. Accurate neutron-capture cross sections also were obtained for the unresolved resonance region to a maximum energy of 500 keV and, together with the new resonance parameters, used to calculate the astrophysical reaction rates in the temperature range from 5 to 30 keV. A vastly improved set of 95Mo neutron resonance parameters and an astrophysical reaction rate accurate to about 3% were obtained. Firm J π assignments were determined for 261 of the 314 observed resonances. This is a very large improvement over the previously published 32 firm J π assignments for 108 resonances. Also, the number of resonances having both firm J π assignments and Γ γ values was increased by almost a factor of 24—from 11 to 261. Neutron- and total-radiation-width distributions and average resonance spacings, average total radiation widths, and neutron strength functions were obtained for the six different s- and p-wave possibilities. Parameters for the lowest s-wave resonance, which is most important for criticality benchmarks, were obtained with high accuracy. Simple modification of the neutron-capture apparatus and expansion and improvement of data analysis techniques led to a large increase in firm J π assignments for 95 Mo neutron resonances. The resulting astrophysical reaction rate is 20%–30% larger than the currently recommended rate at s-process temperatures, which should lead to better agreement between stellar models and meteoric isotopic anomalies. The neutron-capture cross section at low energies is substantially larger than recommended in the latest evaluation, which is problematical for criticality benchmarks. The average resonance spacing as a function of spin and parity is significantly different from current models. The total-radiation-width distributions are significantly broader than predicted by theory and show significant departures from the expected Gaussian shapes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

New Apparatus for Neutron Capture Measurements on Extra Small Radioactive Samples: The DICER Instrument at LANSCE

We report the neutron capture cross section, the probability per unit area a neutron is absorbed by a nucleus followed by the emission of gamma ray(s), is an important quantity in several fields such as astrophysics, nuclear criticality safety, radiochemical diagnostics, nuclear medicine, nuclear forensics and nuclear security. Accurate knowledge of how neutrons interact with matter is a crucial component to understand physical processes in depth. A great example is the understanding of how our universe was created, a quest that requires accurate modeling in which neutron capture cross sections are a key ingredient

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

New capability for indirect neutron capture measurements: The DICER instrument at LANSCE

The Device for Indirect Capture on Radionuclides (DICER) implements a new indirect technique for (n,γ) studies in which the neutron capture rate is determined from analysis of resonance neutron transmission data. The DICER instrument and associated radionuclide production at the Isotope Production Facility (IPF), both at the Los Alamos Neutron Science Center (LANSCE), as well radioactive sample fabrication, have been under development in the last few years. First measurements on a radioactive sample ( 88 Zr, t ½ =83.4 days), which was recently reported to have an extremely large thermal neutron capture cross section and resonance integral, are planned for the winter of 2021. A performance overview, brief details on the 88Zr fabrication and proof of good operation results will be presented.

47 OTHER INSTRUMENTATION↗

New capability for neutron transmission measurements at LANSCE: The DICER instrument

A new capability for neutron transmission measurements has been developed at the Los Alamos Neutron Science Center (LANSCE). The DICER (Device for Indirect Capture Experiments on Radionuclides) instrument is designed to tightly constrain neutron-capture cross sections for short-lived radionuclides that are beyond the reach of direct techniques, via measurement and analysis of neutron transmission resonances on these same radionuclides. The innovative DICER apparatus enables simultaneous sample-in and sample-out measurements, thus minimizing the amount of sample material needed and reducing the measurements time by half. A description of the current status of the new transmission station, along with a performance overview and results from known reactions, will be presented here.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Progress Toward an Indirect Neutron Capture Capability at LANSCE: October 2018 – September 2019

We describe progress developing the Device for Indirect Capture Experiments on Radionuclides (DICER) on flight path 13 at the Lujan Center at the Los Alamos Neutron Science Center (LANSCE). This capability is being developed to tightly constrain neutron-capture cross section on short-lived radioactive nuclides of high importance to weapons-program sponsors via neutron total cross section measurements on the same nuclides. In this report, we describe progress in this endeavor during October 2018 through September 2019.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗