Search NASA⌕ Search

Engineering topics

Koenecke, Richard

Publications and source records attributed to Koenecke, Richard.

Reflective Coatings for the Future X-Ray Mirror Substrates

We present the development of the reflective coating by magnetron sputtering deposition onto precisely-fabricated thin X-ray mirrors. Our goal is to remove distortion induced by the coating and then keep their surface pro les. We first addressed the uniform coating to minimize the distortion by introducing a mask to control the spatial distribution of the coating thickness. The uniformity was finally achieved within 1%. We next tried a platinum single-layer coating on a glass substrate with a dimension of 200 mm 125 mm. The distortion caused by the frontside coating with a thickness of 320 A was found to be at most 1 m, smaller than the previous results obtained from the non-uniform coating. We then carried out the platinum coating with the same amount of the thickness on the backside surface of the glass substrate. The surface pro le of the glass substrate was fully recovered, indicating that the residual stress was successfully balanced by the backside coating. Furthermore, we tried to an iridium single-layer coating with a thickness of 150 Aon the silicon mirrors. The frontside coating caused the degradation of the imaging quality by 7:5 arcsec in half-power width. However, the backside coating with the same amount of the thickness reduced this degradation to be 3:4 arcsec. Finally, an additional backside coating with a thickness of 100 A and the annealing to relax the residual stress were found to eliminate the distortion completely; the final degradation of the imaging quality was only 0:4 arcsec.

Mori, Hideyuki↗

Performance of NICER Flight X-Ray Concentrator

Neutron star Interior Composition ExploreR (NICER) is a NASA instrument to be onboard International Space Station, which is equipped with 56 pairs of an X-ray concentrator (XRC) and a silicon drift detector for high timing observations. The XRC is based on an epoxy replicated thin aluminum foil X-ray mirror, similar to those of Suzaku and ASTRO-H (Hitomi), but only a single stage parabolic grazing incidence optic. Each has a focal length of 1.085 m and a diameter of 105 mm, with 24 confocally aligned parabolic shells. Grazing incident angles to individual shells range from 0.4 to 1.4 deg. The flight 56 XRCs have been completed and successfully delivered to the payload integration. All the XRC was characterized at the NASA/GSFC 100-m X-ray beamline using 1.5 keV X-rays (some of them are also at 4.5 keV). The XRC performance, effective area and point spread function, was measured by a CCD camera and a proportional counter. The average effective area is about 44 sq cm at 1.5 keV and about 18 sq cm at 4.5 keV, which is consistent with a micro-roughness of 0.5 nm from individual shell reflectivity measurements. The XRC focuses about 91% of X-rays into a 2mm aperture at the focal plane, which is the NICER detector window size. Each XRC weighs only 325 g. These performance met the project requirement. In this paper, we will present summary of the flight XRC performance as well as co-alignment results of the 56 XRCs on the flight payload as it is important to estimate the total effective for astronomical observations.

X-ray concentrator↗

First Peek of ASTRO-H Soft X-Ray Telescope (SXT) In-Orbit Performance

ASTRO-H (Hitomi) is a Japanese X-ray astrophysics satellite just launched in February, 2016, from Tanegashima, Japan by a JAXA's H-IIA launch vehicle. It has two Soft X-ray Telescopes (SXTs), among other instruments, that were developed by the NASA Goddard Space Flight Center in collaboration with ISAS/JAXA and Nagoya University. One is for an X-ray micro-calorimeter instrument (Soft X-ray Spectrometer, SXS) and the other for an X-ray CCD camera (Soft X-ray Imager, SXI), both covering the X-ray energy band up to 15 keV. The two SXTs were fully characterized at the 30-m X-ray beam line at ISAS/JAXA. The combined SXT+SXS system effective area is about 250 and 300 cm(exp 2) at 1 and 6 keV, respectively, although observations were performed with the gate valve at the dewar entrance closed, which blocks most of low energy X-rays and some of high energy ones. The angular resolution for SXS is 1.2 arcmin (Half Power Diameter, HPD). The combined SXT+SXI system effective area is about 370 and 350 cm (exp 2) at 1 and 6 keV, respectively. The angular resolution for SXI is 1.3 arcmin (HPD). The both SXTs have a field of view of about 16 arcmin (FWHM of their vignetting functions).The SXT+SXS field of view is limited to 3 x 3 arcmin by the SXS array size. In-flight data available to the SXT team was limited at the time of this conference and a point-like source data is not available for the SXT+SXS. Although due to lack of attitude information we were unable to reconstruct a point spread function of SXT+SXI, according to RXJ1856.5-3754 data, the SXT seems to be working as expected in terms of imaging capability. As for the overall effective area response for both SXT+SXS and SXT+SXI, consistent spectral model fitting parameters with the previous measurements were obtained for Crab and G21.5-0.9 data. On the other hand, their 2-10 keV fluxes differ by about 20% at this point. Calibration work is still under progress. The SXT is the latest version of the aluminum foil X-ray mirror, which is extremely light-weight and very low cost, yet produces large effective area over a wide energy-band. Its area-mass ratio is the largest, 16 cm(exp 2)/kg, among ASTRO-H, Chandra, and XMM-Newton mirrors. The aluminum foil mirror is a still compelling technology depending on the mission science goal.

X-rays↗