Search NASA⌕ Search

Engineering topics

Koffas, T.

Publications and source records attributed to Koffas, T..

25 records · Page 2

Event reconstruction in a liquid xenon Time Projection Chamber with an optically-open field cage

nEXO is a proposed tonne-scale neutrinoless double beta decay (0νββ) experiment using liquid 136 Xe (LXe) in a Time Projection Chamber (TPC) to read out ionization and scintillation signals. Between the field cage and the LXe vessel, a layer of LXe (“skin” LXe) is present, where no ionization signal is collected. Only scintillation photons are detected, owing to the lack of optical barrier around the field cage. Here, in this work, we show that the light originating in the skin LXe region can be used to improve background discrimination by 5% over previous published estimates. This improvement comes from two elements. First, a fraction of the γ-ray background is removed by identifying light from interactions with an energy deposition in the skin LXe. Then, background from 222 Rn dissolved in the skin LXe can be efficiently rejected by tagging the α decay in the 214 Bi- 214 Po chain in the skin LXe.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reflectance of Silicon Photomultipliers at Vacuum Ultraviolet Wavelengths

Characterization of the vacuum ultraviolet (VUV) reflectance of silicon photomultipliers (SiPMs) is important for large-scale SiPM-based photodetector systems. In this work, we report the angular dependence of the specular reflectance in vacuum of SiPMs manufactured by Fondazionc Bruno Kessler (FBK) and Hamamatsu Photonics K.K. (HPK) over wavelengths ranging from 120 to 280 nm. Refractive index and extinction coefficient of the thin silicon-dioxide film deposited on the surface of the FBK SiPMs are derived from reflectance data of an FBK silicon wafer with the same deposited oxide film as SiPMs. The diffuse reflectance of SiPMs is also measured at 193 nm. We use the VUV spectral dependence of the optical constants to predict the reflectance of the FBK silicon wafer and FBK SiPMs in liquid xenon.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurements of electron transport in liquid and gas Xenon using a laser-driven photocathode

Measurements of electron drift properties in liquid and gaseous xenon are reported. The electrons are generated by the photoelectric effect in a semitransparent gold photocathode driven in transmission mode with a pulsed ultraviolet laser. The charges drift and diffuse in a small chamber at various electric fields and a fixed drift distance of 2.0 cm. At an electric field of 0.5 kV/cm, the measured drift velocities and corresponding temperature coefficients respectively are 1.97 ± 0.04 mm/µs and (-0.69 ± 0.05)%/K for liquid xenon, and 1.42 ± 0.03 mm/µs and (+0.11 ± 0.01)%/K for gaseous xenon at 1.5 bar. In addition, we measure longitudinal diffusion coefficients of 25.7±4.6 cm2/s and 149±23 cm2/s, for liquid and gas, respectively. The quantum efficiency of the gold photocathode is studied at the photon energy of 4.73 eV in liquid and gaseous xenon, and vacuum. These charge transport properties and the behavior of photocathodes in a xenon environment are important in designing and calibrating future large scale noble liquid detectors.

Njoya, Oumarou↗

Strip sensor performance in prototype modules built for ATLAS ITk

ATLAS experiment is preparing an upgrade of its detector for High-Luminosity LHC (HL-LHC) operation. The upgrade involves installation of the new all-silicon Inner Tracker (ITk). In the context of the ITk preparations, more than 80 strip modules were built with prototype barrel sensors. They were tested with electrical readout on a per-channel basis. In general, an excellent performance was observed, consistent with previous ASIC-level and sensor-level tests. However, the lessons learned included two phenomena important for the future phases of the project. First was the need to store and test the modules in a dry environment due to humidity sensitivity of the sensors. The second was an observation of high noise regions for 2 modules. The high noise regions were tested further in several ways, including monitoring the performance as a function of time and bias voltage. Additionally, direct sensor-level tests were performed on the affected channels. The inter-strip resistance and bias resistance tests showed low values, indicating a temporary loss of the inter-strip isolation. A subsequent recovery of the noise performance was observed. Here we present the test details, an analysis of how the inter-strip isolation affects the module noise, and the relationship with sensor-level quality control tests.

47 OTHER INSTRUMENTATION↗

Humidity sensitivity of large area silicon sensors: Study and implications

The production of large area sensors is one of the main challenges that the ATLAS collaboration faces for the new Inner-Tracker full-silicon detector. During the prototype fabrication phase for the High Luminosity Large Hadron Collider upgrade, several ATLAS institutes observed indications of humidity sensitivity of large area sensors, even at relative humidities well below the dew point. Specifically, prototype Barrel and End-Cap silicon strip sensors fabricated in 6-inch wafers manifest a prompt decrease of the breakdown voltage when operating under high relative humidity, adversely affecting the performance of the sensors. In addition to the investigation of these prototype sensors, a specific fabrication batch with special passivation is also studied, allowing for a deeper understanding of the responsible mechanisms. Here we present an extensive study of this behaviour on large area sensors. The locations of the hotspots at the breakdown voltage at high humidity are revealed using different infrared thermography techniques. Several palliative treatments are attempted, proving the influence of sensor cleaning methods, as well as baking, on the device performance, but no improvement on the humidity sensitivity was achieved. Furthermore, a study of the incidence of the sensitivity in different batches is also presented, introducing a hypothesis of the origins of the humidity sensitivity associated to the sensor edge design, together with passivation thickness and conformity. Several actions to be taken during sensor production and assembly are extracted from this study, in order to minimize the impact of humidity sensitivity on the performance of large area silicon sensors for High Energy Physics experiments.

47 OTHER INSTRUMENTATION↗

Measurement of the scintillation and ionization response of liquid xenon at MeV energies in the EXO-200 experiment

In this work, liquid xenon (LXe) is employed in a number of current and future detectors for rare event searches. We use the EXO-200 experimental data to measure the absolute scintillation and ionization yields generated by γ interactions from 228 Th (2615 keV), 226 Ra (1764 keV), and 60 Co (1332 keV and 1173 keV) calibration sources, over a range of electric fields. The W value that defines the recombination-independent energy scale is measured to be 11.5±0.5 (syst.) ±0.1 (stat.) eV. These data are also used to measure the recombination fluctuations in the number of electrons and photons produced by the calibration sources at the MeV scale, which deviate from extrapolations of lower-energy data. Additionally, a semiempirical model for the energy resolution of the detector is developed, which is used to constrain the recombination efficiency, i.e., the fraction of recombined electrons that result in the emission of a detectable photon. Detailed measurements of the absolute charge and light yields for MeV-scale electron recoils are important for predicting the performance of future neutrinoless double β -decay detectors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the Spectral Shape of the $β$-Decay of 137 Xe to the Ground State of 137 Cs in EXO-200 and Comparison with Theory

Herein we report on a comparison between the theoretically predicted and experimentally measured spectra of the first-forbidden nonunique $β$-decay transition 137 Xe ( 7/2 - ) → 137 Cs ( 7/2 + ) . The experimental data were acquired by the EXO-200 experiment during a deployment of an AmBe neutron source. The ultralow background environment of EXO-200, together with dedicated source deployment and analysis procedures, allowed for collection of a pure sample of the decays, with an estimated signal to background ratio of more than 99 to 1 in the energy range from 1075 to 4175 keV. In addition to providing a rare and accurate measurement of the first-forbidden nonunique $β$-decay shape, this work constitutes a novel test of the calculated electron spectral shapes in the context of the reactor antineutrino anomaly and spectral bump.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗