Search NASA⌕ Search

Engineering topics

Koglin, J.

Publications and source records attributed to Koglin, J..

Anomalous two-photon Compton scattering

Abstract X-ray free-electron lasers can generate radiation pulses with extreme peak intensities at short wavelengths. This enables the investigation of laser–matter interactions in a regime of high fields, yet at a non-relativistic ponderomotive potential, where ordinary rules of light–matter interaction may no longer apply and nonlinear processes are starting to become observable. Despite small cross-sections, first nonlinear effects in the hard x-ray regime have recently been observed in solid targets, including x-ray-optical sum-frequency generation (XSFG), x-ray second harmonic generation (XSHG) and two-photon Compton scattering (2PCS). Nonlinear interactions of bound electrons in the x-ray range are fundamentally different from those dominating at optical frequencies. Whereas in the optical regime nonlinearities are predominantly caused by anharmonicities of the atomic potential in the chemical bonds, x-ray nonlinearities far above atomic resonances are expected to be due to nonlinear oscillations of quasi-free electrons, including inner-shell atomic electrons. While the quasi-free-electron model agrees reasonably well with the experimental data for XSFG and XSHG, 2PCS measurements have led to unexpected results: the energy of the nonlinearly scattered photons from non-relativistic electrons shows a substantial unexpected red shift in addition to the Compton shift that is well beyond that predicted by a nonlinear quantum electrodynamics model for free electrons. A potential explanation for the spectral broadening is based on a previously unexplored scattering process that involves the whole atom rather than just quasi-free electrons. A first simulation that includes the atomic binding potential was successful in describing a broadening of the spectrum of the nonlinearly scattered photons to longer wavelengths for soft x-rays. However, the same model does not show any broadening at hard x-ray wavelengths, which is in agreement with other simulation approaches. To this point no calculation has been able to reproduce the experimentally observed broadening. Here we present further experimental data of 2PCS for an extended parameter range using additional diagnostics. In particular, we present measurements of the electron momentum distribution during the interaction that strongly suggest that the spectral broadening is not caused by an increased plasma temperature. We extend our measurement of the magnitude of the red shift in beryllium to > 1.9 k e V in addition to the Compton shift expected for free electrons and expand the measurement of the angular distribution to include forward scattering angles. We also present first measurements of 2PCS from diamond.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Performance of ePix10K, a high dynamic range, gain auto-ranging pixel detector for FELs

ePix10K is a hybrid pixel detector developed at SLAC for demanding free-electron laser (FEL) applications, providing an ultrahigh dynamic range (245 eV to 88 MeV) through gain auto-ranging. It has three gain modes (high, medium and low) and two auto-ranging modes (high-to-low and medium-to-low). The first ePix10K cameras are built around modules consisting of a sensor flip-chip bonded to 4 ASICs, resulting in 352 × 384 pixels of 100 µm x 100 µm each. We present results from extensive testing of three ePix10K cameras with FEL beams at LCLS, resulting in a measured noise floor of 245 eV rms, or 67 e - equivalent noise charge (ENC), and a range of 11 000 photons at 8 keV. We demonstrate the linearity of the response in various gain combinations: fixed high, fixed medium, fixed low, auto-ranging high to low, and auto-ranging medium-to-low, while maintaining a low noise (well within the counting statistics), a very low cross-talk, perfect saturation response at fluxes up to 900 times the maximum range, and acquisition rates of up to 480 Hz. Finally, we present examples of high dynamic range x-ray imaging spanning more than 4 orders of magnitude dynamic range (from a single photon to 11 000 photons/pixel/pulse at 8 keV). Achieving this high performance with only one auto-ranging switch leads to relatively simple calibration and reconstruction procedures. The low noise levels allow usage with long integration times at non-FEL sources. ePix10K cameras leverage the advantages of hybrid pixel detectors with high production yield and good availability, minimize development complexity through sharing the hardware, software and DAQ development with all other versions of ePix cameras, while providing an upgrade path to 5 kHz, 25 kHz and 100 kHz in three steps over the next few years, matching the LCLS-II requirements.

47 OTHER INSTRUMENTATION↗

Delayed Onset of Nonthermal Melting in Single-Crystal Silicon Pumped with Hard X Rays

Here, we monitor the onset of nonthermal melting in single-crystal silicon by implementing an x-ray pump–x-ray probe scheme. Using the ultrashort pulses provided by the Linac Coherent Light Source (SLAC) and a custom-built split-and-delay line for hard x rays, we achieve the temporal resolution needed to detect the onset of the transition. Our data show no loss of long-range order up to 150 ± 40 fs from photoabsorption, which we interpret as the time needed for the electronic system to equilibrate at or above the critical nonthermal melting temperature. Once such equilibration is reached, the loss of long-range atomic order proceeds inertially and is completed within 315 ± 40 fs from photoabsorption.

47 OTHER INSTRUMENTATION↗

Optimal Pulse Processing, Pile-Up Decomposition, and Applications of Silicon Drift Detectors at LCLS

Silicon drift detectors (SDDs) revolutionized spectroscopy in fields as diverse as geology and dentistry. For a subset of experiments at ultrafast, X-ray free-electron lasers (FELs), SDDs can make substantial contributions. Often the unknown spectrum is interesting, carrying science data, or the background measurement is useful to identify unexpected signals. Many measurements involve only several discrete photon energies known a priori, allowing single-event decomposition of pile-up and spectroscopic photon counting. We designed a pulse function and demonstrated that the signal amplitude (i.e., proportional to the detected energy and obtained from fitting with the pulse function), rise time, and pulse height are interrelated, and at short peaking times, the pulse height and pulse area are not optimal estimators for detected energy; instead, the signal amplitude and rise time are obtained for each pulse by fitting, thus removing the need for pulse shaping. By avoiding pulse shaping, rise times of tens of nanoseconds resulted in reduced pulse pile-up and allowed decomposition of remaining pulse pile-up at photon separation times down to hundreds of nanoseconds while yielding time-of-arrival information with the precision of 10 ns. Waveform fitting yields simultaneously high energy resolution and high counting rates (two orders of magnitude higher than current digital pulse processors). At pulsed sources or high photon rates, photon pile-up still occurs. We showed that pile-up spectrum fitting is relatively simple and preferable to pile-up spectrum deconvolution. We then developed a photon pile-up statistical model for constant intensity sources, extended it to variable intensity sources (typical for FELs), and used it to fit a complex pileup spectrum. We subsequently developed a Bayesian pile-up decomposition method that allows decomposing pile-up of single events with up to six photons from six monochromatic lines with 99% accuracy. The usefulness of SDDs will continue into the X-ray FEL era of science. Their successors, the ePixS hybrid pixel detectors, already offer hundreds of pixels, each with a similar performance to an SDD, in a compact, robust and affordable package.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The hyperion particle-γ detector array

Hyperion is a new high-efficiency charged-particle γ-ray detector array which consists of a segmented silicon telescope for charged-particle detection and up to fourteen high-purity germanium clover detectors for the detection of coincident γ rays. The array will be used in nuclear physics measurements and Stockpile Stewardship studies and replaces the STARLiTeR array. In conclusion, this article discusses the features of the array and presents data collected with the array in the commissioning experiment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Investigation of discrete states and quasidiscrete structures observed in 150 Sm and 152 Sm using the (p, tγ) reaction

New levels and γ-ray transitions were identified in 150,152 Sm utilizing the (p,t) reaction and particle-γ coincidence data. A large, peak-like structure observed between 2.3–3.0 MeV in excitation energy in the triton energy spectra was also investigated. The orbital angular-momentum transfer was probed by comparing the experimental angular distributions of the outgoing tritons to calculated distorted wave Born approximation curves. The angular distributions of the outgoing tritons populating the peak-like structure are remarkably similar in the two reactions and are significantly different from the angular distributions associated with the nearby continuum region. Relative partial cross sections for the observed levels, angle averaged between 34 and 58 degrees, were measured. In 150 Sm, 39(4)% of the strength of the peak-like structure could be accounted for by the observed discrete states. This compares with a value of 93(15)% for 152 Sm

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The NuSTAR extragalactic surveys: the number counts of active galactic nuclei and the resolved fraction of the cosmic X-ray background

We present the 3–8 keV and 8–24 keV number counts of active galactic nuclei (AGNs) identified in the Nuclear Spectroscopic Telescope Array (NuSTAR) extragalactic surveys. NuSTAR has now resolved 33%–39% of the X-ray background in the 8–24 keV band, directly identifying AGNs with obscuring columns up to ∼10{sup 25} cm{sup −2}. In the softer 3–8 keV band the number counts are in general agreement with those measured by XMM-Newton and Chandra over the flux range 5×10{sup −15} ≲ S(3–8 keV)/erg s{sup −1} cm{sup −2} ≲ 10{sup −12} probed by NuSTAR. In the hard 8–24 keV band NuSTAR probes fluxes over the range 2×10{sup −14} ≲ S(8–24 keV)/erg s{sup −1} cm{sup −2} ≲ 10{sup −12}, a factor ∼100 fainter than previous measurements. The 8–24 keV number counts match predictions from AGN population synthesis models, directly confirming the existence of a population of obscured and/or hard X-ray sources inferred from the shape of the integrated cosmic X-ray background. The measured NuSTAR counts lie significantly above simple extrapolation with a Euclidian slope to low flux of the Swift/BAT 15–55 keV number counts measured at higher fluxes (S(15–55 keV) ≳ 10{sup −11} erg s{sup −1} cm{sup −2}), reflecting the evolution of the AGN population between the Swift/BAT local (z<0.1) sample and NuSTAR’s z∼1 sample. CXB synthesis models, which account for AGN evolution, lie above the Swift/BAT measurements, suggesting that they do not fully capture the evolution of obscured AGNs at low redshifts.

79 ASTRONOMY AND ASTROPHYSICS↗

The NuSTAR Extragalactic Surveys: The Number Counts Of Active Galactic Nuclei And The Resolved Fraction Of The Cosmic X-ray Background

We present the 3-8 kiloelectronvolts and 8-24 kiloelectronvolts number counts of active galactic nuclei (AGNs) identified in the Nuclear Spectroscopic Telescope Array (NuSTAR) extragalactic surveys. NuSTAR has now resolved 33 percent -39 percent of the X-ray background in the 8-24 kiloelectronvolts band, directly identifying AGNs with obscuring columns up to approximately 10 (exp 25) per square centimeter. In the softer 3-8 kiloelectronvolts band the number counts are in general agreement with those measured by XMM-Newton and Chandra over the flux range 5 times 10 (exp -15) less than or approximately equal to S (3-8 kiloelectronvolts) divided by ergs per second per square centimeter less than or approximately equal to 10 (exp -12) probed by NuSTAR. In the hard 8-24 kiloelectronvolts band NuSTAR probes fluxes over the range 2 times 10 (exp -14) less than or approximately equal to S (8-24 kiloelectronvolts) divided by ergs per second per square centimeter less than or approximately equal to 10 (exp -12), a factor approximately 100 times fainter than previous measurements. The 8-24 kiloelectronvolts number counts match predictions from AGN population synthesis models, directly confirming the existence of a population of obscured and/or hard X-ray sources inferred from the shape of the integrated cosmic X-ray background. The measured NuSTAR counts lie significantly above simple extrapolation with a Euclidian slope to low flux of the Swift/BAT15-55 kiloelectronvolts number counts measured at higher fluxes (S (15-55 kiloelectronvolts) less than or approximately equal to 10 (exp -11) ergs per second per square centimeter), reflecting the evolution of the AGN population between the Swift/BAT local (redshift is less than 0.1) sample and NuSTAR's redshift approximately equal to 1 sample. CXB (Cosmic X-ray Background) synthesis models, which account for AGN evolution, lie above the Swift/BAT measurements, suggesting that they do not fully capture the evolution of obscured AGNs at low redshifts

nucle↗

First observation of low-energy γ-ray enhancement in the rare-earth region

Here, the γ-ray strength function and level density in the quasi-continuum of 151,153 Sm have been measured using bismuth germanate shielded Ge clover detectors of the STARLiTeR system. The Compton shields allow an extraction of the γ strength down to unprecedentedly low γ energies of ≈ 500 keV. For the first time an enhanced low-energy γ-ray strength has been observed in the rare-earth region. In addition, for the first time both the upbend and the well-known scissors resonance have been observed simultaneously for the same nucleus. Hauser-Feshbach calculations show that this strength enhancement at low γ energies could have an impact of 2 3 orders of magnitude on the (n, γ) reaction rates for r-process nucleosynthesis.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Improved measurement of the half-life of the J π = 8 - nuclear isomer 152m 2 Eu

The standard γ-ray energy calibration source 152 Eu is well known based on the 13.5 y decay of its ground state. Nevertheless, in addition to this decay 152 Eu also has two relatively long-lived isomeric states: a 9 h J π =0 - state at E * =46 keV and a 96 min J π =8 - state at E * =148 keV. In this work, we report a new measurement of the half-lives of both of these isomeric states. Excited states in 152 Eu were populated following the 154 Sm (p,3n) reaction using a 25 MeV proton beam from the K-150 cyclotron at the Cyclotron Institute of Texas A&M University. Post irradiation, γ rays from the de-excitation of the long lived isomeric states were measured using the six BGO shielded high-purity germanium (HPGe) clover detectors that are part of the STARLiTeR array. The half-life of the J π =8 - isomer 152m 2 Eu was obtained by measuring the decrease in intensity of the 90 keV γ ray from the cascade to the ground state. The half-life of this state was measured to be 95.8(4) min which is in agreement with and significantly more precise than the previously measured value of 96(1) min. In a manner similar to the ground state the second long-lived isomer 151m 1 Eu, the J π =0 - state at 46 keV, β decays to excited states in 152 Gd and 152 Sm. Also, the half-life of this state was measured to be 9.39(7) h using five γ-ray transitions.

36 MATERIALS SCIENCE↗

Report on 240 Am(n,x) surrogate cross section test measurement

The main goal of the test measurement was to determine the feasibility of the 243 Am(p,t) reaction as a surrogate for 240 Am(n,f). No data cross section data exists for neutron induced reactions on 240 Am; the half-life of this isotope is only 2.1 days making direct measurements difficult, if not impossible. The 48-hour experiment was conducted using the STARS/LIBERACE experimental facility located at the 88 Inch Cyclotron at Lawrence Berkeley National Laboratory in August 2011. A description of the experiment and results is given. The beam energy was initially chosen to be 39 MeV in order to measure an equivalent neutron energy range from 0 to 20 MeV. However, the proton beam was not stopped in the farady cup and the beam was deposited in the surrounding shielding material. The shielding material was not conductive, and a beam current, needed for proper tuning of the beam as well as experimental monitoring, could not be read. If the 240 Am(n,f) surrogate experiment is to be run at LBNL, simple modifications to the beam collection site will need to be made. The beam energy was reduced to 29 MeV, which was within an energy regime of prior experiments and tuning conditions at STARS/LIBERACE. At this energy, the beam current was successfully tuned and measured. At 29 MeV, data was collected with both the 243 Am and 238 U targets. An example particle identification plot is shown in Fig. 1. The triton-fission coincidence rate for the 243 Am target and 238 U target were measured. Coincidence rates of 0.0233(1) cps and 0.150(6) cps were observed for the 243 Am and 238 U targets, respectively. The difference in count rate is largely attributed to the available target material - the 238 U target contains approximately 7 times more atoms than the 243 Am. A proton beam current of ~0.7 nA was used for measurements on both targets. Assuming a full experimental run under similar conditions, an estimate for the run time needed was made. Figure 2 shows the number of days needed as a function of acceptable uncertainty for a measurement of 1-20 MeV equivalent neutron energy, binned into 200 keV increments. A 5% measurement will take 3 days for U, but 20 days for Am. It may be difficult to be the sole user of the LBNL cyclotron, or another facility, for such an extended period. However, a 10% measurement will take 19 hours for U, and 5 days for Am. Such a run period is more reasonable and will allow for the first ever measurement of the 240 Am(n,f) cross section. We also anticipate 40% more beam time being available at Texas A&M Cyclotron Institute compared to LBNL in FY2012. The increased amount of beam time will allow us to accumulate better statistics then what would have been available at LBNL.

43 PARTICLE ACCELERATORS↗