Agile high resolution arbitrary waveform generator with jitterless frequency stepping

Jitterless transition of the programmable clock waveform is generated employing a set of two coupled direct digital synthesis (DDS) circuits. The first phase accumulator in the first DDS circuit runs at least one cycle of a common reference clock for the DDS circuits ahead of the second phase accumulator in the second DDS circuit. As a phase transition through the beginning of a phase cycle is detected from the first phase accumulator, a first phase offset word and a second phase offset word for the first and second phase accumulators are calculated and loaded into the first and second DDS circuits. The programmable clock waveform is employed as a clock input for the RAM address controller. A well defined jitterless transition in frequency of the arbitrary waveform is provided which coincides with the beginning of the phase cycle of the DDS output signal from the second DDS circuit.

42 ENGINEERING↗

A Novel Phase-Coherent Programmable Clock for High-Precision Arbitrary Waveform Generation Applied to Digital Ion Trap Mass Spectrometry

Digital ion trap (DIT) mass spectrometry requires the ability to precisely and accurately produce waveforms. The quality of the mass spectra produced in terms of resolution and mass accuracy depend on the resolution and precision of the applied waveforms. This publication reveals a novel method for the production of arbitrary waveforms in general and then applies the method to the production of DIT waveforms. Arbitrary waveforms can be created by varying the clock frequency input to a programmable read only memory that is then input to a digital-to-analog converter (DAC). The arbitrary waveform is composed of a defined number of points that are triggered to be written after programmed numbers of clock cycles to define the arbitrary waveform. The novelty introduced here is that the direct digital synthesis (DDS) generated clock frequency can be precisely changed as the arbitrary waveform is written because we have developed a method to rapidly switch the DDS frequency exactly at the end of the output clock cycle allowing exact timing of multiple transitions to produce precise and temporally complex waveforms. Changing the frequency only at the end of the output clock cycle is a phase coherent process that permits precise timing between each point in the arbitrary waveform. The waveform generation technique was demonstrated by creating a prototype that was used to operate a digital ion trap mass spectrometer. The jitter in the phase-coherent DDS TTL output that was used as the frequency variable clock was 20 ps. This jitter represents the realizable limit of precision for waveform generation. The rectangular waveforms used to operate the mass spectrometer were created with counters that increased the jitter to 100 ps. The mass resolution achieved was 5000 at m/z = 414. This resolution corresponds to a jitter of 275 ps assuming DC fluctuations and overshoots in the waveform are insignificant. Resolution should improve with increasing mass because the waveforms have longer periods while the jitter should remain constant. Given the current limit of the variable clock resolution, much better mass resolution should be achievable with future generations of the waveform production system. The agility of the DDS function generators permits the phase-coherent variable clock to be switched at a rate up to 250 MHz. This permits arbitrary waveforms to be produced with much more temporal complexity than previously possible.

47 OTHER INSTRUMENTATION↗

The Effect of Endcap Electrode Holes on the Resonant Ejection from an Ion Trap

The effect of endcap holes on resonance ejection of trapped ions has never been fully examined in the literature. The presence of holes in the electrodes adds higher order negative components to the field inside the trap. The absolute magnitudes of these components that define the field along the central axis of the trap were defined by numerically simulating the fields inside the trap and then using least squares to fit a polynomial expansion of the potential. The absolute value of the field components were found to increase with increasing hole size. The fitted potential was then used to reexamine the amplitude response function. The addition of negative higher order field components produces up to four inflection points in the amplitude response function. The new inflection points may produce multiple jump phenomena in forward scans as well as a jump condition in the reverse scan mode that has not previously been considered. The shape of the amplitude response function is dependent on the hole size and the amplitude of the dipole excitation waveform at constant buffer gas pressure. The shape of the function has interesting implications for the resonance ejection process. This work provides new insights into the resonance excitation process in nonlinear ion traps.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Derivation of Mathematical Expressions to Define Resonant Ejection from Square and Sinusoidal Wave Ion Traps

The use of resonant ejection for mass analysis with ion traps is increasing primarily because it markedly improves the mass range and resolution of ion traps. Unfortunately, an easy-to-use analytical expression that defines the ejection mass as a function of the trapping and excitation frequencies is missing in the literature because the secular frequency of the ions in sinusoidal ion traps is not easily determined for all stable values of qz from the Mathieu equation. However, the ion secular frequency for all stable values of qz in digital ion traps can be readily determined from Hill s equation. We have taken this expression and solved it for qz to produce an analytical expression for the ejection mass as a function of trapping and excitation frequency. We also recognized that the expression for the ion mass during resonant ejection for a square wave driven trap can be converted to an expression for a sinusoidal wave trap merely by multiplication by a factor of 4/ . These new expressions open up the possibility of rapid mass calibration for any method of resonant ejection from square or sinusoidal wave driven ion traps.

97 MATHEMATICS AND COMPUTING↗

Trapping of Intact, Singly-Charged, Bovine Serum Albumin Ions Injected from the Atmosphere with a 10-cm Diameter, Frequency-Adjusted Linear Quadrupole Ion Trap

High-resolution real-time particle mass measurements have not been achievable because the enormous amount of kinetic energy imparted to the particles upon expansion into vacuum competes with and overwhelms the forces applied to the charged particles within the mass spectrometer. It is possible to reduce the kinetic energy of a collimated particulate ion beam through collisions with a buffer gas while radially constraining their motion using a quadrupole guide or trap over a limited mass range. Controlling the pressure drop of the final expansion into a quadrupole trap permits a much broader mass range at the cost of sacrificing collimation. To achieve high-resolution mass analysis of massive particulate ions, an efficient trap with a large tolerance for radial divergence of the injected ions was developed that permits trapping a large range of ions for on-demand injection into an awaiting mass analyzer. The design specifications required that frequency of the trapping potential be adjustable to cover a large mass range and the trap radius be increased to increase the tolerance to divergent ion injection. The large-radius linear quadrupole ion trap was demonstrated by trapping singly-charged bovine serum albumin ions for on-demand injection into a mass analyzer. Additionally, this work demonstrates the ability to measure an electrophoretic mobility cross section (or ion mobility) of singly-charged intact proteins in the low-pressure regime. This work represents a large step toward the goal of high-resolution analysis of intact proteins, RNA, DNA, and viruses.

59 BASIC BIOLOGICAL SCIENCES↗