Search NASA⌕ Search

Engineering topics

Kolodziejczak, J.

Publications and source records attributed to Kolodziejczak, J..

The Imaging X-Ray Polarimetry Explorer (IXPE): Overview

Mission background: Imaging x-ray polarimetry in 2–8 kiloelectronvolt band; NASA Astrophysics Small Explorer (SMEX) selected in 2017 January. Orbit: Pegasus-XL (airborne) launch in 2021, from Kwajalein; Equatorial circular orbit at greater than or approximately equal to 540 kilometers (620 kilometers, goal) altitude. Flight system: Spacecraft, payload structure, and integration by Ball Aerospace - Deployable payload boom from Orbital-ATK, under contract to Ball; X-ray Mirror Module Assemblies by NASA/MSFC; X-ray (polarization-sensitive) Instruments by IAPS/INAF (Istituto di Astrofisica e Planetologia Spaziali / Istituto Nazionale di Astrofisica) and INFN (Istituto Nazionale di Fisica Nucleare). Ground system: ASI (Agenzia Spaziale Italiana) Malindi ground station, with Singapore backup; Mission Operations Center at LASP (Laboratory for Atmospheric and Space Physics, University of Colorado); Science Operations Center at NASA/MSFC; Data archive at HEASARC (High Energy Astrophysics Science Archive Research Center), (NASA/GSFC), mirror at ASI Data Center. Science: Active galactic nuclei; Microquasars; Radio pulsars and pulsar wind nebulae; Supernova remnants; Magnetars; Accreting x-ray pulsars.

X-ray polarimetry space missio↗

Calibration of the ART-XC/SRG X-ray Mirror Modules

Seven x-ray mirror modules are being fabricated at the Marshall Space Flight Center (MSFC) for the Astronomical Roentgen Telescope (ART) instrument to be launched on board of the Spektrum Roentgen Gamma (SRG) Mission. As they are completed, the modules are tested and calibrated at the MSFC's 104-m Stray Flight Facility. The results of these calibration measurements and comparisons with theoretical models will be presented.

Gubarev, M.↗

ART-XC/SRG: Status of the X-ray Optics Development

The Astronomical Roentgen Telescope (ART) instrument is a hard-x-ray instrument with energy response up to 30 keV that is to be launched on board of the Spectrum Roentgen Gamma (SRG) Mission. The instrument consists of seven identical mirror modules coupled with seven CdTe strip focal-plane detectors. The mirror modules are being developed at the Marshall Space Flight Center (MSFC.) Each module has approx. 65 sq. cm effective area and an on-axis angular resolution of 30 arcseconds half power diameter (HPD) at 8 keV. The current status of the mirror module development and testing will be presented.

Gubarev, M.↗

Status of ART-XC/SRG Instrument

Spectrum Roentgen Gamma (SRG) is an X-ray astrophysical observatory, developed by Russia in collaboration with Germany. The mission will be launched in March 2016 from Baikonur, by a Zenit rocket with a Fregat booster and placed in a 6-month-period halo orbit around L2. The scientific payload consists of two independent telescopes - a soft-x-ray survey instrument, eROSITA, being provided by Germany and a medium-x-ray-energy survey instrument ART-XC being developed by Russia. ART-XC will consist of seven independent, but co-aligned, telescope modules. The NASA Marshall Space Flight Center (MSFC) is fabricating the flight mirror modules for the ART-XC/SRG. Each mirror module will be aligned with a focal plane CdTe double-sided strip detectors which will operate over the energy range of 6-30 keV, with an angular resolution of less than 1′, a field of view of approximately 34′ and an expected energy resolution of about 10 percent at 14 keV.

Pavlinsky, M.↗

ART-XC/SRG: Status of the X-ray Optics Development

The Astronomical Roentgen Telescope (ART) instrument is a hard-x-ray instrument with energy response up to 30 keV that is to be launched on board of the Spectrum Roentgen Gamma (SRG) Mission. The instrument consists of seven identical mirror modules coupled with seven CdTe strip focal-plane detectors. The mirror modules are being developed at the Marshall Space Flight Center (MSFC.) Each module has approximately 65 sq. cm effective area and an on-axis angular resolution of 30 arcseconds half power diameter (HPD) at 8 keV. The current status of the mirror module development and testing will be presented.

Gubarev, M.↗

Development and Calibration of the ART-XC Mirror Modules for the Spectrum Rontgen Gamma Mission

The Spectrum-Röntgen-Gamma (SRG) mission is a Russian-lead X-ray astrophysical observatory that carries two co-aligned X-ray telescope systems. The primary instrument is the German-led extended ROentgen Survey with an Imaging Telescope Array (eROSITA), a 7-module X-ray telescope system that covers the energy range from 0.2-12 keV. The complementary instrument is the Astronomical Roentgen Telescope -- X-ray Concentrator (ART-XC or ART), a 7-module Xray telescope system that provides higher energy coverage, up to 30 keV.

Ramsey, B.↗

Results of a Deep Chandra Observation of the Crab Nebula and Pulsar

The Crab Nebula and pulsar were observed for a total of 150 ksec with the LETG/HRC-S combination aboard the Chandra X-Ray Observatory in 2000, January and February. One of the principal aims of the experiment was to study the emission from the pulsar as a function of pulse phase. Neutron stars are believed to be formed with core temperatures of 10(exp 11) K. As the pulsar is the best studied of the young known neutron stars with an age of only 940 yrs, it should be possible to observe thermal emission from the hot stellar surface which in turn constrains equations of state. The pulsar, on the other hand, is a powerful non-thermal emitter, powering an X-ray bright synchrotron nebula which, in Einstein and ROSAT observations, overshadowed the fainter thermal surface emission. Making use of the high angular resolution provided by Chandra we were able to detect X-rays from the Crab-pulsar at all pulse phases. We discuss whether this detection is indeed of thermal emission or of a faint synchrotron component of the pulsed emission from the magnetosphere. We further comment on dynamical effects observed in the pulsar-wind outflow and the analysis of the LETG spectral data, especially near the oxygen edge.

Weisskopf, M. C.↗

Results of a Deep Chandra Observation of the Crab Nebula and Pulsar

The Crab Nebula and pulsar were observed for a total of 150 ksec with the LETG/HRC-S combination aboard the Chandra X-Ray Observatory in 2000, January. One of the principal aims of the experiment was to study the emission of from the pulsar as a function of pulse phase. Neutron stars are believed to be formed with core temperatures of T(sub c) approx. 10(sup 11) K. As the pulsar is the youngest known neutron star with an age of only 940 yrs, it should be possible to observe thermal emission from the hot stellar surface which in turn constrains equations of state. The pulsar, on the other hand, is a powerful non-thermal emitter, powering an X-ray bright synchrotron nebula which, in Einstein and ROSAT observations, overshadowed the fainter thermal surface emission. Making use of the high angular resolution provided by Chandra we were able to detect X-rays from the Crab-pulsar at all pulse phases. We discuss whether this detection is indeed of thermal emission or of a faint synchrotron component of the pulsed emission from the magnetosphere. We further report on dynamical effects observed in the pulsar-wind outflow and the analysis of the LETG spectral data, especially near the oxygen edge. The results of the spectral analysis has interesting implications for the composition of the interstellar medium.(c) 2000.: American Astronomical Society. All rights reserved

Weisskopf, M. C.↗

Results of a Deep Chandra Observation of the Crab Nebula and Pulsar

The Crab Nebula and pulsar were observed for a total of 150 ksec with the LETG/HRC-S combination aboard the Chandra X-Ray Observatory in 2000, January. One of the principal aims of the experiment was to study the emission of from the pulsar as a function of pulse phase. Neutron stars are believed to be formed with core temperatures of 10(exp 11). As the pulsar is the youngest known neutron star with an age of only 940 yrs, it should be possible to observe thermal emission from the hot stellar surface which in turn constrains equations of state. The pulsar, on the other hand, is a powerful non-thermal emitter, powering an X-ray bright synchrotron nebula which, in Einstein and ROSAT observations, overshadowed the fainter thermal surface emission. Making use of the high angular resolution provided by Chandra we were able to detect X-rays from the Crab-pulsar at all pulse phases. We discuss whether this detection is indeed of thermal emission or of a faint synchrotron component of the pulsed emission from the magnetosphere. We further report on dynamical effects observed in the pulsar-wind outflow and the analysis of the LETG spectral data, especially near the oxygen edge. The results of the spectral analysis has interesting implications for the composition of the interstellar medium.

Weisskopf, M. C.↗

Polycapillary X-Ray Optics for X-Ray Astronomy

High-energy x-ray spectrometry from astronomical sources is difficult due to low flux rates and high background. Polycapillary x-ray optics can be used to increase the signal-to-noise ratio by focusing photons onto a small energy dispersive detector. Two optics, both designed for x-ray astronomy, have been built and tested as collimating optics with a microfocus x-ray source for x-ray energies up to 70 keV and as focusing optics with parallel x-rays up to 50 keV. Results from these tests show that polycapillary x-ray optics have transmission efficiencies ranging from 5% to 40% and signal gains ranging from 5 to over 100 for energies up to 50 keV. Furthermore the results show that these optics have potential for use up to 100 keV. The experimental results as well as simulations for the measured and for optimized optics will be discussed.

Russell, C. H.↗

Replicated Wolter-I X-ray Optics for Lightweight, High Angular Resolution, Large Collecting Area X-Ray Telescopes

The next generation of orbiting x-ray observatories will require high angular resolution telescopes that have an order of magnitude greater collecting area in the 0.1-10 keV spectral region than those currently under construction, but with a much lower weight and cost per unit area. Replicated Wolter-I x-ray optics have the potential to meet this requirement. The currently demonstrated capabilities of replicated Wolter-I optics will be described, and a development plan for creating lightweight, high angular resolution, large effective area x-ray telescopes will be presented.

Joy, M.↗

Absolute Calibration of the AXAF Telescope Effective Area

The prelaunch calibration of AXAF encompasses many aspects of the telescope. In principle, all that is needed is the complete point response function. This is, however, a function of energy, off-axis angle of the source, and operating mode of the facility. No single measurement would yield the entire result. Also, any calibration made prior to launch will be affected by changes in conditions after launch, such as the change from one g to zero g. The reflectivity of the mirror and perhaps even the detectors can change as well, for example by addition or removal of small amounts of material deposited on their surfaces. In this paper, we give a broad view of the issues in performing such a calibration, and discuss how they are being addressed in prelaunch preparation of AXAF. As our title indicates, we concentrate here on the total throughput of the observatory. This can be thought of as the integral of the point response function, i.e. the encircled energy, out ot the largest practical solid angle for an observation. Since there is no standard x-ray source in the sky whose flux is known to the -1% accuracy we are trying to achieve, we must do this calibration on the ground. we also must provide a means for monitoring any possible changes in this calibration from pre-launch until on-orbit operation can transfer the calibration to a celestial x-ray source whose emission is stable. In this paper, we analyze the elements of the absolute throughput calibration, which we call Effective Area. We review the requirements for calibrations of components or subsystems of the AXAF facility, including mirror, detectors, and gratings. We show how it is necessary to calibrate this ground-based detection system at standard man-made x-ray sources, such as electron storage rings. We present the status of all these calibrations, with indications of the measurements remaining to be done, even though the measurements on the AXAF flight optics and detectors will have been completed by the time this paper is presented. We evaluate progress toward the goal of making 1% measurements of the absolute x-ray flux from astrophysical sources, so that comparisons can be made with their emission at other wavelengths, in support of observations such as the Sunyaev-Zeldovitch effect, which can give absolute distance measurements independent of the traditional distance measuring techniques in astronomy.

Kellogg, E.↗