Search NASA⌕ Search

Engineering topics

Konôpková, Zuzana

Publications and source records attributed to Konôpková, Zuzana.

X-ray induced grain boundary formation and grain rotation in Bi 2 Se 3

Optimizing grain boundary characteristics in polycrystalline materials can improve their properties. Many processing methods have been developed for grain boundary manipulation, including the use of intense radiation in certain applications. Here, in this work, we used X-ray free electron laser pulses to irradiate single-crystalline bismuth selenide (Bi 2 Se 3 ) and observed grain boundary formation and subsequent grain rotation in response to the X-ray radiation. Our observations with simultaneous transmission X-ray microscopy and X-ray diffraction demonstrate how intense X-ray radiation can rapidly change size and texture of grains.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effects of mosaic crystal instrument functions on x-ray Thomson scattering diagnostics

Mosaic crystals, with their high integrated reflectivities, are widely employed in spectrometers used to diagnose high energy density systems. X-ray Thomson scattering (XRTS) has emerged as a powerful diagnostic tool of these systems, providing in principle direct access to important properties such as the temperature via detailed balance. However, the measured XRTS spectrum is broadened by the spectrometer instrument function (IF), and without careful consideration of the IF one risks misdiagnosing system conditions. Here, we consider in detail the IF of 40 and 100 μm mosaic Highly Annealed Pyrolytic Graphite crystals, and how the broadening varies across the spectrometer in an energy range of 6.7–8.6 keV. Notably, we find a strong asymmetry in the shape of the IF toward higher energies. As an example, we consider the effect of the asymmetry in the IF on the temperature inferred via XRTS for simulated 80 eV CH plasmas and find that the temperature can be overestimated if an approximate symmetric IF is used. We, therefore, expect a detailed consideration of the full IF will have an important impact on system properties inferred via XRTS in both forward modeling and model-free approaches.

47 OTHER INSTRUMENTATION↗

Diamond precipitation dynamics from hydrocarbons at icy planet interior conditions

The pressure and temperature conditions at which precipitation of diamond occurs from hydrocarbon mixtures is important for modelling the interior dynamics of icy planets. However, there is substantial disagreement from laboratory experiments, with those using dynamic compression techniques finding much more extreme conditions are required than in static compression. Here we report the time-resolved observation of diamond formation from statically compressed polystyrene, (C 8 H 8 ) n , heated using the 4.5 MHz X-ray pulse trains at the European X-ray Free Electron Laser facility. Diamond formation is observed above 2,500 K from 19 GPa to 27 GPa, conditions representative of Uranus’s and Neptune’s shallow interiors, on 30 μs to 40 μs timescales. This is much slower than may be observed during the ~10 ns duration of typical dynamic compression experiments, revealing reaction kinetics to be the reason for the discrepancy. In conclusion, reduced pressure and temperature conditions for diamond formation has implications for icy planetary interiors, where diamond subduction leads to heating and could drive convection in the conductive ice layer that has a role in their magnetic fields.

79 ASTRONOMY AND ASTROPHYSICS↗

MHz free electron laser x-ray diffraction and modeling of pulsed laser heated diamond anvil cell

A new diamond anvil cell experimental approach has been implemented at the European x-ray Free Electron Laser, combining pulsed laser heating with MHz x-ray diffraction. In this report we use this setup to determine liquidus temperatures under extreme conditions, based on the determination of time-resolved crystallization. The focus is on a Fe-Si-O ternary system, relevant for planetary cores. This time-resolved diagnostic is complemented by a finite-element model, reproducing temporal temperature profiles measured experimentally using streaked optical pyrometry. This model calculates the temperature and strain fields by including (i) pressure and temperature dependencies of material properties, and (ii) the heat-induced thermal stress, including feedback effect on material parameter variations. Making our model more realistic, these improvements are critical as they give 7000 K temperature differences compared to previous models. Laser intensities are determined by seeking minimal deviation between measured and modeled temperatures. Combining models and streak optical pyrometry data extends temperature determination below detection limit. The presented approach can be used to infer the liquidus temperature by the appearance of SiO 2 diffraction spots. In addition, temperatures obtained by the model agree with crystallization temperatures reported for Fe–Si alloys. Our model reproduces the planetary relevant experimental conditions, providing temperature, pressure, and volume conditions. Those predictions are then used to determine liquidus temperatures at experimental timescales where chemical migration is limited. This synergy of novel time-resolved experiments and finite-element modeling pushes further the interpretation capabilities in diamond anvil cell experiments.

36 MATERIALS SCIENCE↗

A MHz X-ray diffraction set-up for dynamic compression experiments in the diamond anvil cell

An experimental platform for dynamic diamond anvil cell (dDAC) research has been developed at the High Energy Density (HED) Instrument at the European X-ray Free Electron Laser (European XFEL). Advantage was taken of the high repetition rate of the European XFEL (up to 4.5 MHz) to collect pulse-resolved MHz X-ray diffraction data from samples as they are dynamically compressed at intermediate strain rates (≤10 3 s −1 ), where up to 352 diffraction images can be collected from a single pulse train. The set-up employs piezo-driven dDACs capable of compressing samples in ≥340 µs, compatible with the maximum length of the pulse train (550 µs). Results from rapid compression experiments on a wide range of sample systems with different X-ray scattering powers are presented. A maximum compression rate of 87 TPa s −1 was observed during the fast compression of Au, while a strain rate of ∼1100 s −1 was achieved during the rapid compression of N 2 at 23 TPa s −1 .

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Ethane and methane at high pressures: Structure and stability

We have performed a combined experimental and theoretical study of ethane and methane at high pressures of up to 120 GPa at 300 K using x-ray diffraction and Raman spectroscopies and the USPEX ab initio evolutionary structural search algorithm, respectively. For ethane, we have determined the crystallization point, for room temperature, at 2.7 GPa and also the low pressure crystal structure (phase A). This crystal structure is orientationally disordered (plastic phase) and deviates from the known crystal structures for ethane at low temperatures. Moreover, a pressure induced phase transition has been identified, for the first time, at 13.6 GPa to a monoclinic phase B, the structure of which is solved based on good agreement with the experimental results and theoretical predictions. For methane, our x-ray diffraction measurements are in agreement with the previously reported high-pressure structures and equation of state (EOS). Finally, we have determined the EOSs of ethane and methane, which provides a solid basis for the discussion of their relative stability at high pressures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Laser heating system at the Extreme Conditions Beamline, P02.2, $\mathrm{PETRA III}$

A laser heating system for samples confined in diamond anvil cells paired with in situ X-ray diffraction measurements at the Extreme Conditions Beamline of PETRA III is presented. The system features two independent laser configurations (on-axis and off-axis of the X-ray path) allowing for a broad range of experiments using different designs of diamond anvil cells. The power of the continuous laser source can be modulated for use in various pulsed laser heating or flash heating applications. An example of such an application is illustrated here on the melting curve of iron at megabar pressures. The optical path of the spectroradiometry measurements is simulated with ray-tracing methods in order to assess the level of present aberrations in the system and the results are compared with other systems, that are using simpler lens optics. Based on the ray-tracing the choice of the first achromatic lens and other aspects for accurate temperature measurements are evaluated.

47 OTHER INSTRUMENTATION↗

Compression-rate dependence of pressure-induced phase transitions in Bi

Abstract It is qualitatively well known that kinetics related to nucleation and growth can shift apparent phase boundaries from their equilibrium value. In this work, we have measured this effect in Bi using time-resolved X-ray diffraction with unprecedented 0.25 ms time resolution, accurately determining phase transition pressures at compression rates spanning five orders of magnitude (10 –2 –10 3 GPa/s) using the dynamic diamond anvil cell. An over-pressurization of the Bi-III/Bi-V phase boundary is observed at fast compression rates for different sample types and stress states, and the largest over-pressurization that is observed is ΔP = 2.5 GPa. The work presented here paves the way for future studies of transition kinetics at previously inaccessible compression rates.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

X-ray Free Electron Laser-Induced Synthesis of ε -Iron Nitride at High Pressures

The ultrafast synthesis of ε-Fe 3 N 1+x in a diamond-anvil cell (DAC) from Fe and N 2 under pressure was observed using serial exposures of an X-ray free electron laser (XFEL). When the sample at 5 GPa was irradiated by a pulse train separated by 443 ns, the estimated sample temperature at the delay time was above 1400 K, confirmed by in situ transformation of α- to γ-iron. Ultimately, the Fe and N 2 reacted uniformly throughout the beam path to form Fe 3 N 1.33 , as deduced from its established equation of state (EOS). We thus demonstrate that the activation energy provided by intense X-ray exposures in an XFEL can be coupled with the source time structure to enable exploration of the time-dependence of reactions under high-pressure conditions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A portable on-axis laser-heating system for near-90° X-ray spectroscopy: application to ferropericlase and iron silicide

A portable IR fiber laser-heating system, optimized for X-ray emission spectroscopy (XES) and nuclear inelastic scattering (NIS) spectroscopy with signal collection through the radial opening of diamond anvil cells near 90°with respect to the incident X-ray beam, is presented. The system offers double-sided on-axis heating by a single laser source and zero attenuation of incoming X-rays other than by the high-pressure environment. A description of the system, which has been tested for pressures above 100 GPa and temperatures up to 3000 K, is given. The XES spectra of laser-heated Mg 0.67 Fe 0.33 O demonstrate the potential to map the iron spin state in the pressure–temperature range of the Earth's lower mantle, and the NIS spectra of laser-heated FeSi give access to the sound velocity of this candidate of a phase inside the Earth's core. This portable system represents one of the few bridges across the gap between laser heating and high-resolution X-ray spectroscopies with signal collection near 90°.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗