Search NASASearch

Engineering topics

Koncsek, J. L.

Publications and source records attributed to Koncsek, J. L..

Supersonic Test of the 10-Inch Bifurcated Two-Stage Supersonic Inlet (BTSSI)

Experimental results from testing of a novel supersonic inlet model in NASA Glenn Research Center's 10- by 10-foot supersonic wind tunnel are presented. The patented inlet concept, called Two-Stage Supersonic Inlet (TSSI), incorporates a large cavity, or throat slot, in the supersonic diffuser intended to enhance the stability of the normal shock. The present embodiment of the concept is a bifurcated twin-duct) design. During the course of testing an unusual 'semi-started' mode of operation was encountered. The inlet was able to spill up to 30 percent of the captured airstream without fully expelling the normal shock. In this mode, the total pressure recovery dropped approximately 6 percent without increasing steady-state distortion. Dynamic instrumentation at the cowl lip station indicates the semi-start mode may be a series of unstart/restart cycles with frequency ranging from 0.2 to 20 Hz. Engine face total pressure measurements indicate a modest impact due to this event. However, since the current test article does not have a representative subsonic diffuser (and is in fact separated), it is unclear how this mode of operation would effect an engine. Further investigation of this phenomenon is required before it is fully understood. Prior testing of the TSSI concept allowed extension of fully started inlet operation to regions of significantly reduced supply flow without reducing recovery. The test article was a smaller scale than the present test and was a single duct design. In the present test, the expanded range of stable operation with high recovery was not realized.

Carlin, C. M.

VSTOL tilt nacelle aerodynamics and its relation to fan blade stresses

A scale model of a VSTOL tilt nacelle with a 0.508 m single stage fan was tested in a low speed wind tunnel to ascertain inlet aerodynamic and fan aeromechanical performance over the low speed flight envelope. Fan blade stress maxima occurred at discrete rotational speeds corresponding to integral engine order vibrations of the first flatwise bending mode. Increased fan blade stress levels coincided with internal boundary layer separation but became severe only when the separation location had progressed to the entry lip region of the inlet.

Shaw, R. J.

VSTOL tilt nacelle aerodynamics and its relation to fan blade stresses

A scale model of a VSTOL tilt nacelle with a 0.508 m single stage fan was tested in the NASA Lewis 9x15 Low Speed Wind Tunnel to ascertain inlet aerodynamic and fan aeromechanical performance over the low speed flight envelope. Fan blade stress maxima occurred at discrete rotational speeds corresponding to integral engine order vibrations of the first flatwise bending mode. Increased fan blade stress levels coincided with internal boundary layer separation occurring but became severe only when the separation location had progressed to the entry lip region of the inlet. The inlet/fan system could operate within the low speed flight envelope without incurring fan blade stress limits although boundary layer separation did occur for certain operating conditions.

Shaw, R. J.

Operating characteristics of an inlet model tested with a 0.5m powered fan at high angles of attack

An inlet model designed for high angle of attack capability, coupled to a .508 m tip diameter turbofan simulator, was tested in the NASA-Lewis Research Center's 9-by 15-ft low speed wind tunnel. The test variables were: tunnel velocity, 0 to 75 m/s; inlet angle of attack, 0 to 120 deg; and fan face corrected airflow per unit area, 75 to 200 kg/s sqm. The inlet flow separation boundaries, the fan face total pressure recovery and distortion characteristics, and the fan blade vibratory stresses were determined. The recovery, distortion, and stress levels showed no abrupt changes at the onset of separation, but became gradually more unfavorable as the size and intensity of the separation increased as induced by increasingly severe operating conditions. Performance characteristics for a large scale model of the inlet were estimated from these test results.

Koncsek, J. L.

Fan inlet for a V/STOL airplane

An inlet was designed for a tilt nacelle lift/cruise fan. A complete set of low speed data was obtained with a 38-cm diameter cold-flow model, and a partial set of data was obtained with a 140-cm-diameter inlet coupled to a high bypass turbofan. The results indicate that a fixed-geometry inlet is a viable concept for the proposed application. Analyses of the data demonstrate that at high angles of incidence and at low airflow rates inlet-flow separation is strongly sensitive to Reynolds number and, consequently, the large-scale inlet has a significantly greater range of separation-free operation.

Koncsek, J. L.

Low speed tests of a fixed geometry inlet for a tilt nacelle V/STOL airplane

Test data were obtained with a 1/4 scale cold flow model of the inlet at freestream velocities from 0 to 77 m/s (150 knots) and angles of attack from 45 deg to 120 deg. A large scale model was tested with a high bypass ratio turbofan in the NASA/ARC wind tunnel. A fixed geometry inlet is a viable concept for a tilt nacelle V/STOL application. Comparison of data obtained with the two models indicates that flow separation at high angles of attack and low airflow rates is strongly sensitive to Reynolds number and that the large scale model has a significantly improved range of separation-free operation.

Syberg, J.

Experimental evaluation of a Mach 3.5 axisymmetric inlet

Wind tunnel test results for a large scale inlet model designed for Mach 3.5 are presented and compared with analytical predictions. The inlet is an axisymmetric mixed-compression type with a lip diameter of 49.723 cm. The inlet design was developed using analytical procedures. Data are shown for freestream Mach numbers from 0.6 to 3.5. The test results indicate that boundary layer bleed requirements can be accurately predicted. Good agreement was obtained with analytical predictions of the flowfield structure and boundary layer development in the supersonic diffuser yielding high performance at the design Mach number. The highest engine face total pressure recovery at Mach 3.5 was 85.8%; this was obtained at 0.05 Mach tolerance with only 2.8% total pressure distortion and 13.4% bleed. In the started Mach number range from 1.6 to 3.5, the total pressure recovery in the throat, downstream of the terminal normal shock, ranged between 91% and 95%. Total pressure losses in the subsonic diffuser varied from 3% to 13%. The higher losses occuring between Mach 2.5 and 3.2 were believed to be caused by the rapid rate of increase in the area of the diffuser just downstream of the throat, possibly coupled with inadequate centerbody throat bleed. In the unstarted mode at transonic speeds, the maximum inlet flow was over 99% of the theoretical maximum capture mass-flow.

Syberg, J.

Bleed system design technology for supersonic inlets.

A boundary layer bleed system design procedure for supersonic inlets, with emphasis on the selection of bleed hole geometry, is described. Available experimental bleed hole performance data, coupled with bleed drag calculations, show that holes with shallow inclination are superior to holes normal to the surface in terms of overall inlet performance. Recent test results from large-scale inlet models indicate that bleed hole size, bleed hole length, and boundary layer velocity profile upstream of the bleed region are important parameters in the design of an effective and efficient bleed system.

Syberg, J.

Transonic and supersonic test of a Mach 2.65 mixed-compression axisymmetric intake

The test results describe isolated intake performance between Mach 0.95 and the cruise Mach number of 2.65 at angles of incidence from +5 to -5 deg. Maximum total pressure recoveries of over 94 percent with 10 percent distortion were recorded at the compressor face in the Mach range from 2.65 to 2.4. Typical cruise operating recovery was 91 percent with 13 percent distortion, 7 percent bleed, 5 percent corrected flow stability margin, and 2.2 deg angle-of-incidence tolerance without need for control action. In the started range below Mach 2.4, recoveries were 2 percent to 4 percent lower than the recoveries above Mach 2.4, and the distortion increased to approximately 20 percent. At Mach 0.95 the maximum measured capture flow was 99.4 percent of the theoretical choked value. The recovery was 97.1 percent with less than 10 percent distortion.

Koncsek, J. L.