Search NASA⌕ Search

Engineering topics

Kondo, K

Publications and source records attributed to Kondo, K.

At least 19 records

X-ray spectral diagnostics of laser harmonic generation in the interaction of relativistic femtosecond laser pulses with clusters

It is shown that the production of X-ray emission spectra in the interaction of high-intensity laser radiation with cluster targets may be affected by the bichromatic oscillating electric field arising from the generation of the second harmonic of laser radiation. A technique is proposed for diagnosing harmonic generation in laser – cluster interactions using the spectral line profiles of multiply charged helium ions. The efficiency of second harmonic generation at a laser intensity of 3 × 10{sup 18} W cm{sup -2} is shown to amount to about 2%. (extreme laser radiation: physics and fundamental applications)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Extreme field limits in the interaction of laser light with ultrarelativistic electrons

The critical electric field of quantum electrodynamics is so strong that it produces electron-positron pairs from vacuum, converting the energy of light into matter. This field has become feasible through the construction of extremely high power lasers or/and with the sophisticated use of nonlinear processes in relativistic plasmas. A feasibility of the experiments on the collision of laser light and high intensity electromagnetic pulses, generated by relativistic flying mirrors, with relativistic electrons for the studying of extreme field limits in the nonlinear interaction of electromagnetic waves is discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electron energy transport in the thin foil driven by high contrast high intensity laser pulse

The fast electron spectrum was measured for the interaction between the thin foil and the relativistic optical high field. There were two components in the electron spectrum. The higher temperature component was almost explained by the ponderomotive formula T{sub e}[MeV] = 0.511({radical}(1+I{sub 18}{lambda}{sup 2}{sub {mu}m}/1.37)-1). The total electron spectrum including the lower temperature component was also explained by a simple model.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quantitative measurement of hard x-ray spectra for high intensity laser produced plasma

X-ray line spectra ranging from 17 to 77 keV were quantitatively measured with a Laue spectrometer, composed of a cylindrically curved crystal and a detector. Either a visible CCD detector coupled with a CsI phosphor screen or an imaging plate can be chosen, depending on the signal intensities and exposure times. The absolute sensitivity of the spectrometer system was calibrated using pre-characterized laser-produced x-ray sources and radioisotopes. The integrated reflectivity for the crystal is in good agreement with predictions by an open code for x-ray diffraction. The energy transfer efficiency from incident laser beams to hot electrons, as the energy transfer agency for specific x-ray line emissions, is derived as a consequence of this work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A study of H+ production using metal hydride and other compounds by means of laser ion source

A laser ion source can provide wide variety of ion beams from solid target materials, however, it has been difficult to create proton beam efficiently. We examined capability of proton production using beeswax, polyethylene, and metal hydrides (MgH2 and ZrH2) as target materials. The results showed that beeswax and polyethylene could not be used to produce protons because these targets are transparent to the laser wavelength of 1064 nm. On the other hand, the metal hydrides could supply protons. Although the obtained particle numbers of protons were less than those of the metal ions, the metal hydrides could be used as a target for proton laser ion source.

08 HYDROGEN↗

Laser ion source with solenoid for Brookhaven National Laboratory-electron beam ion source

The electron beam ion source (EBIS) preinjector at Brookhaven National Laboratory (BNL) is a new heavy ion-preinjector for relativistic heavy ion collider (RHIC) and NASA Space Radiation Laboratory (NSRL). Laser ion source (LIS) is a primary ion source provider for the BNL-EBIS. LIS with solenoid at the plasma drift section can realize the low peak current ({approx}100 {micro}A) with high charge ({approx}10 nC) which is the BNL-EBIS requirement. The gap between two solenoids does not cause serious plasma current decay, which helps us to make up the BNL-EBIS beamline.

43 PARTICLE ACCELERATORS↗

Laser ion source with a double pulse laser system

To extend an ion beam pulse of a laser ion source, multiple laser shots could be used. To check the feasibility of this idea, we tested double laser irradiations on an iron target. When the interval of the two laser shots is longer than 10 {mu}s, the obtained ion current profile was expressed as a sum of two individual expanded laser plasmas. However, if the interval is too close, a current reduction was observed. This technique can be effectively applied to low charge state ion production.

43 PARTICLE ACCELERATORS↗

Laser ion source with long pulse width for RHIC-EBIS

The Electron Beam Ion Source (EBIS) at Brookhaven National Laboratory is a new heavy ion-projector for RHIC and NASA Space Radiation Laboratory. Laser Ion Source (LIS) with solenoid can supply many kinds of ion from solid targets and is suitable for long pulse length with low current as ion provider for RHIC-EBIS. In order to understand a plasma behavior for fringe field of solenoid, we measure current, pulse width and total ion charges by a new ion probe. The experimental result indicates that the solenoid confines the laser ablation plasma transversely. Laser ion source needs long pulse length with limited current as primary ion provider for RHIC-EBIS. New ion probe can measure current distribution for the radial positions along z axis. The beam pulse length is not effected by magnetic field strength. However, the currents and charges decay with the distance from the end of solenoid. These results indicate that solenoid field has important role for plasma confinement not longitudinally but transversely and solenoid is able to have long pulse length with sufficient total ion charges. Moreover, the results are useful for a design of the extraction system for RHIC-EBIS.

43 PARTICLE ACCELERATORS↗

Linear accelerator design study with direct plasma injection scheme for warm dense matter

Warm Dense Matter (WDM) is a challenging science field, which is related to heavy ion inertial fusion and planetary science. It is difficult to expect the behavior because the state with high density and low temperature is completely different from ideal condition. The well-defined WDM generation is required to understand it. Moderate energy ion beams ({approx} MeV/u) slightly above Bragg peak is an advantageous method for WDM because of the uniform energy deposition. Direct Plasma Injection Scheme (DPIS) with a Interdigital H-mode (IH) accelerator has a potential for the beam parameter. We show feasible parameters of the IH accelerator for WDM. WDM physics is a challenging science and is strongly related to Heavy Ion Fusion science. WDM formation by Direct Plasma Injection Scheme (DPIS) with IH accelerator, which is a compact system, is proposed. Feasible parameters for IH accelerator are shown for WDM state. These represents that DPIS with IH accelerator can access a different parameter region of WDM.

43 PARTICLE ACCELERATORS↗

Experimental evidence of nonthermal acceleration of relativistic electrons by an intensive laser pulse

Nonthermal acceleration of relativistic electrons is investigated with an intensive laser pulse. An energy distribution function of energetic particles in the universe or cosmic rays is well represented by a power-law spectrum, therefore, nonthermal acceleration is essential to understand the origin of cosmic rays. A possible candidate for the origin of cosmic rays is wakefield acceleration at relativistic astrophysical perpendicular shocks. The wakefield is considered to be excited by large-amplitude precursor light waves in the upstream of the shocks. Substituting an intensive laser pulse for the large amplitude light waves, we performed a model experiment of the shock environments in a laboratory plasma. An intensive laser pulse was propagated in a plasma tube created by imploding a hollow polystyrene cylinder, as the large amplitude light waves propagated in the upstream plasma at an astrophysical shock. Nonthermal electrons were generated, and the energy distribution functions of the electrons have a power-law component with an index of {approx}2. We described the detailed procedures to obtain the nonthermal components from data obtained by an electron spectrometer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Model experiment of cosmic ray acceleration due to an incoherent wakefield induced by an intense laser pulse

The first report on a model experiment of cosmic ray acceleration by using intense laser pulses is presented. Large amplitude light waves are considered to be excited in the upstream regions of relativistic astrophysical shocks and the wakefield acceleration of cosmic rays can take place. By substituting an intense laser pulse for the large amplitude light waves, such shock environments were modeled in a laboratory plasma. A plasma tube, which is created by imploding a hollow polystyrene cylinder, was irradiated by an intense laser pulse. Nonthermal electrons were generated by the wakefield acceleration and the energy distribution functions of the electrons have a power-law component with an index of {approx}2. The maximum attainable energy of the electrons in the experiment is discussed by a simple analytic model. In the incoherent wakefield the maximum energy can be much larger than one in the coherent field due to the momentum space diffusion or the energy diffusion of electrons.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of multi-channel electron spectrometer

In order to obtain the angular dependent electron energy distributions, we developed a multichannel electron spectrometer (MCESM) with high energy and angular resolutions. The MCESM consists of seven small electron spectrometers set in every 5 deg. on the basement, each of which detection range is up to 25 MeV. In the experiment, we successfully obtained electron spectra from imploded cone-shell target as well as gold plane target irradiated by ultraintense (300 J/5 ps) laser beam.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Commissioning of the EBIS-based heavy ion preinjector at Brookhaven

The status is presented of the commissioning of a new heavy ion preinjector at Brookhaven National Laboratory. This preinjector uses an Electron Beam Ion Source (EBIS), and an RFQ and IH Linac, both operating at 100.625 MHz, to produce 2 MeV/u ions of any species for use, after further acceleration, at the Relativistic Heavy Ion Collider (RHIC) and the NASA Space Radiation Laboratory (NSRL). Among the increased capabilities provided by this preinjector are the ability to produce ions of any species, and the ability to switch between multiple species in 1 second, to simultaneously meet the needs of both science programs. For initial setup, helium beam from EBIS was injected and circulated in the Booster synchrotron. Following this, accelerated Au{sup 32+} and Fe{sup 20+} beams were transported to the Booster injection point, fulfilling DOE requirements for project completion.

43 PARTICLE ACCELERATORS↗

Beam commissioning results for the RFQ and MEBT of the EBIS based preinjector for RHIC

The EBIS based preinjector for both the Relativistic Heavy Ion Collider (RHIC) and NASA Space Radiation Laboratory (NSRL) is now being commissioned at Brookhaven National Laboratory (BNL). In 2008, the RFQ for the project was delivered and commissioned using Test EBIS, which was built to demonstrate the high current EBIS's performance. A dedicated beamline after the RFQ was assembled to confirm the RFQ's performance, and the beam energy was measured by a bending dipole magnet. In November 2009, the RFQ was moved to the final location and the vanes were realigned. The beam commissioning with the RHIC-EBIS was started again during March 2010. The RFQ accelerates ions from 17 keV/u to 300 keV/u and operates at 100.625 MHz. It is followed by a short Medium Energy Beam Transport (MEBT), which consists of four quadrupoles and one buncher cavity. Some temporary diagnostics for this commissioning include an emittance probe, TOF system, fast Faraday cup, and beam current measurement units. As of September 2010, the RFQ and the MEBT show expected performance with He{sup +}, Au{sup 32+} and Fe{sup 20+} beams. Further commissioning for higher intensity beams is in progress.

43 PARTICLE ACCELERATORS↗

Correlation between laser accelerated MeV proton and electron beams using simple fluid model for target normal sheath acceleration

High density energetic electrons that are created by intense laser plasma interactions drive MeV proton acceleration. The correlation between accelerated MeV protons and escaped electrons is experimentally investigated at laser intensities in the range of 10{sup 18}-10{sup 19} W/cm{sup 2} with S-polarization. Observed proton maximum energies are linearly proportional to escaped electron slope temperatures with a scaling coefficient of about 10. In the context of the simple analytical fluid model for transverse normal sheath acceleration, hot electron sheath density near the target rear surface can be estimated if an empirical acceleration time is assumed.

07 ISOTOPE AND RADIATION SOURCES↗

Confinement of laser plasma by solenoidal field for laser ion source

A laser ion source can provide high current, highly charged ions with a simple structure. However, it was not easy to control the ion pulse width. To provide a longer ion beam pulse, the plasma drift length, which is the distance between laser target and extraction point, has to be extended and as a result the plasma is diluted severely. Previously, we applied a solenoid field to prevent reduction of ion density at the extraction point. Although a current enhancement by a solenoid field was observed, plasma behavior after a solenoid magnet was unclear because plasma behavior can be different from usual ion beam dynamics. We measured a transverse ion distribution along the beam axis to understand plasma motion in the presence of a solenoid field.

43 PARTICLE ACCELERATORS↗

DPIS for warm dense matter

Warm Dense Matter (WDM) offers an challenging problem because WDM, which is beyond ideal plasma, is in a low temperature and high density state with partially degenerate electrons and coupled ions. WDM is a common state of matter in astrophysical objects such as cores of giant planets and white dwarfs. The WDM studies require large energy deposition into a small target volume in a shorter time than the hydrodynamical time and need uniformity across the full thickness of the target. Since moderate energy ion beams ({approx} 0.3 MeV/u) can be useful tool for WDM physics, we propose WDM generation using Direct Plasma Injection Scheme (DPIS). In the DPIS, laser ion source is connected to the Radio Frequency Quadrupole (RFQ) linear accelerator directly without the beam transport line. DPIS with a realistic final focus and a linear accelerator can produce WDM.

43 PARTICLE ACCELERATORS↗