Koppenaal, David W

Publications and source records attributed to Koppenaal, David W.

Coupling of an atmospheric pressure microplasma ionization source with an Orbitrap Fusion Lumos Tribrid 1M mass analyzer for ultra-high resolution isotopic analysis of uranium

The coupling of a combined atomic and molecular (CAM) ionization source, the liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma to an Orbitrap Fusion Lumos Tribrid 1M mass spectrometer is described as a significant step towards the elimination of isobaric interferences in elemental/isotopic mass spectrometry. The developed setup permits broadband, elemental mass spectra to be easily acquired at a mass resolution (m/Δm) of 500 000. A new ion source housing and integrated control system provide enhanced stability and sensitivity of the microplasma ion source in comparison to the previous designs. Detailed evaluation of the ion sampling parameters provided insight into differences with other Orbitrap platforms leading to a 5-fold increase in resolution in elemental/isotopic analysis. The roles of data acquisition/ion processing parameters were evaluated with regards to the precision and accuracy of 235 U/ 238 U isotope ratios. Significantly, the precision of those measurements improves as a function of pre-set mass resolution up to a value of 1 000 000, where a precision of 0.086% RSD is obtained for uranium concentrations of 100 ng mL− 1 . Analytical response curves (log–log), acquired for the two uranium isotopes at a resolution of 120 000 were linear (R 2 = 0.9969) over more than 5 orders of magnitude, with limits of detection of 1 pg mL −1 for U. Based on 60 μL injection volumes, this represents a mass of 70 fg 235 U. These figures of merit satisfy International Target Values (ITVs) for Measurement Uncertainties in Safeguarding Nuclear Materials set by the International Atomic Energy Agency (IAEA). Ultimately, and totally unique from beam-type instruments, the move to the higher-resolution Orbitrap platform provides all of the benefits of high mass resolution, with no penalties in sensitivity, precision, or dynamic range for uranium analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Combined distance-of-flight and time-of-flight mass spectrometer

A combined distance-of-flight mass spectrometry (DOFMS) and time-of-flight mass spectrometry (TOFMS) instrument includes an ion source configured to produce ions having varying mass-to-charge ratios, a first detector configured to determine when each of the ions travels a predetermined distance, a second detector configured to determine how far each of the ions travels in a predetermined time, and a detector extraction region operable to direct portions of the ions either to the first detector or to the second detector.

47 OTHER INSTRUMENTATION↗

Proteome Analyses of Strains ATCC 51142 and PCC 7822 of the Diazotrophic Cyanobacterium Cyanothece sp under Culture Conditions Resulting in Enhanced H-2 Production

Cultures of the cyanobacterial genus Cyanothece have been shown to produce high levels of biohydrogen. These strains are diazotrophic and undergo pronounced diurnal cycles when grown under N2-fixing conditions in light-dark cycles. We seek to better understand the way in which proteins respond to these diurnal changes and we performed quantitative proteome analysis of Cyanothece ATCC 51142 and PCC 7822 grown under 8 different nutritional conditions. Nitrogenase expression was limited to N2-fixing conditions, and in the absence of glycerol, nitrogenase gene expression was linked to the dark period. However, glycerol induced expression of nitrogenase during part of the light period, together with cytochrome c oxidase (Cox), glycogen phosphorylase (Glp), and glycolytic and pentose-phosphate pathway (PPP) enzymes. This indicated that nitrogenase expression in the light was facilitated via higher respiration and glycogen breakdown. Key enzymes of the Calvin cycle were inhibited in Cyanothece ATCC 51142 in the presence of glycerol under H2 producing conditions, suggesting a competition between these sources of carbon. However, in Cyanothece PCC 7822, the Calvin cycle still played a role in cofactor recycling during H2 production. Our data comprise the first comprehensive profiling of proteome changes in Cyanothece PCC 7822, and allows an in-depth comparative analysis of major physiological and biochemical processes that influence H2-production in both the strains. Our results revealed many previously uncharacterized proteins that may play a role in nitrogenase activity and in other metabolic pathways and may provide suitable targets for genetic manipulation that would lead to improvement of large scale H2 production.

Environmental Molecular Sciences Laboratory↗

Extension of the Focusable Mass Range in Distance-of-Flight Mass Spectrometry with Multiple Detectors

Since the underlying theory of Distance-of-Flight Mass Spectrometry (DOFMS) was reported in 2007,[1] laboratory results[2, 3] have proven its practical viability. However, these previous implementations of DOFMS considered ion detection only over narrow DOF-detection windows, with 25-mm being the greatest detection length explored. These small mass windows cannot be used to evaluate how DOFMS focusing performs over greater DOF detection lengths and mass ranges. In the present study, we expand on previous studies by placing two spatially selective ion detectors along the detection plane of the DOFMS instrument. Ion signals are simultaneously collected from both DOF detectors in order to simulate DOFMS performance with a longer spatially selective ion detector.

Gundlach-Graham, Alexander W↗

Distance-of-Flight Mass Spectrometry: A New Paradigm for Mass Separation and Detection

Distance-of-flight mass spectrometry (DOFMS) offers the advantages of physical separation of ions, array-detection of ions, focusing of initial ion energy, great simplicity, and truly unlimited mass range. DOFMS instrumentation is similar to that of time-of-flight mass spectrometry (TOFMS) and shares its ion source versatility, batch analysis, and rapid spectral generation rate. With constant-momentum ion acceleration and an ion mirror, there is a time at which ions of all m/z values are energy-focused at their particular distance along the flight path. A pulsed field orthogonal to the flight path drives the ions to reach the detector array at this specific time. Results from a 0.31-m proof-of-principle instrument verify the theoretically predicted energy focus and demonstrate how the range of m/z values impinging on the detector array can be readily changed. DOFMS can potentially be combined sequentially with TOFMS to enable simultaneous scanless MS/MS.

dynamic range↗

Reduction of polyatomic interferences in ICP-MS by collision/reaction cell (CRC-ICP-MS) techniques

Polyatomic and other spectral interferences in plasma source mass spectrometry (PSMS) can be dramatically reduced using collision and reaction cells (CRC). These devices have been used for decades in fundamental studies of ion-molecule chemistry, but have only recently been applied to PSMS. Benefits of this approach as applied in inductively coupled plasma MS (ICP-MS) include interference reduction, isobar separation, and thermalization/focusing of ions. Novel ion-molecule chemistry schemes are now routinely designed and empirically evaluated with relative ease. These “chemical resolution” techniques can avert interferences requiring mass spectral resolutions of >600,000 (m/m). Purely physical ion beam processes, including collisional dampening and collisional dissociation, are also employed to provide improved sensitivity, resolution, and spectral simplicity. CRC techniques are now firmly entrenched in current-day ICP-MS technology, enabling unprecedented flexibility and freedom from many spectral interferences. A significant body of applications has now been reported in the literature. CRC techniques are found to be most useful for specialized or difficult analytical needs and situations, and are employed in both single- and multi-element determination modes.

collision cell↗

Dynamic proteome analysis of Cyanothece sp. ATCC 51142 under constant light

Understanding the dynamic nature of protein abundances provides insights into protein turnover not readily apparent from conventional, static mass spectrometry measurements. This level of data is particularly informative when surveying protein abundances in biological systems subjected to large perturbations or alterations in environment such as cyanobacteria. Our current analysis expands upon conventional proteomic approaches in cyanobacteria by measuring dynamic changes of the proteome using a 13C15N-L-leucine metabolic labeling in Cyanothece ATCC51142. Metabolically labeled Cyanothece ATCC51142 cells grown under nitrogen sufficient conditions in continuous light were monitored longitudinally for isotope incorporation over a 48 h period, revealing 422 proteins with dynamic changes in abundances. In particular, proteins involved in carbon fixation, pentose phosphate pathway, cellular protection, redox regulation, protein folding, assembly and degradation showed higher levels of isotope incorporation suggesting that these biochemical pathways are important for growth under non-diazotrophic conditions. Calculation of relative isotope abundances (RIA) values allowed to measure actual active protein synthesis over time for different biochemical pathways under non-diazotrophic conditions. Overall results demonstrated the utility of 'non-steady state' pulsed metabolic labeling for systems-wide dynamic quantification of the proteome in Cyanothece ATCC51142 that can also be applied to other cyanobacteria.

59 BASIC BIOLOGICAL SCIENCES↗

Dynamic proteomic profiling of a unicellular cyanobacterium Cyanothece ATCC51142 across light-dark diurnal cycles

Unicellular cyanobacteria of the genus Cyanothece are recognized for their ability to execute nitrogen (N2)-fixation in the dark and photosynthesis in the light. Systems-wide dynamic proteomic profiling with mass spectrometry (MS) analysis reveals fundamental insights into the control and regulation of these functions. To expand upon the current knowledge of protein expression patterns in Cyanothece ATCC51142, we performed quantitative proteomic analysis using partial ("unsaturated") metabolic labeling and high mass accuracy LC-MS analysis. This dynamic proteomic profiling identified 721 actively synthesized proteins with significant temporal changes in expression throughout the light-dark cycles, of which 425 proteins matched with previously characterized cycling transcripts. The remaining 296 proteins contained a cluster of proteins uniquely involved in DNA replication and repair, protein degradation, tRNA synthesis and modification, transport and binding, and regulatory functions. Analysis of protein functions revealed that the expression of nitrogenase in the dark is mediated by higher respiration and glycogen metabolism. We have also shown that Cyanothece ATCC51142 utilizes alternative pathways for carbon (C) and nitrogen (N) acquisition, particularly, aspartic acid and glutamate as substrates of C and N, respectively. Utilization of phosphoketolase (PHK) pathway for the conversion of xylulose-5P to pyruvate and acetyl-P likely constitutes an alternative strategy to compensate higher ATP and NADPH demand. In conclusion, this study provides a deeper insight into how Cyanothece ATCC51142 modulates cellular functions to accommodate photosynthesis and N2-fixation within the single cell.

59 BASIC BIOLOGICAL SCIENCES↗

Resolution and Mass Range Performance in Distance-of-flight Mass Spectrometry with a Multichannel Focal-Plane Camera Detector.

Distance-of-flight mass spectrometry (DOFMS) is a velocity-based mass-separation technique in which ions are separated in space along the plane of a spatially selective detector. In the present work, a solid-state charge-detection array, the focal-plane camera (FPC), was incorporated into the DOFMS platform. Use of the FPC with our DOFMS instrument resulted in improvements in analytical performance, usability, and versatility over a previous generation instrument that employed a microchannel-plate/phosphor DOF detector. Notably, FPC detection provided resolution improvements of at least a factor of 2, with typical DOF linewidths of 300 μm (R((fwhm)) = 1000). The merits of solid-state detection for DOFMS are evaluated, and methods to extend the DOFMS mass range are considered.

Array Detection↗

Liquid Sampling-Atmospheric Pressure Glow Discharge Ionization Source for Elemental Mass Spectrometry

A new, low power ionization source for elemental MS analysis of aqueous solutions is described. The liquid sampling-atmospheric pressure glow discharge (LSAPGD) operates by a process wherein the surface of the liquid emanating from a 75 μm i.d. glass capillary acts as the cathode of the direct current glow discharge. Analytecontaining solutions at a flow rate of 100 μL min-1 are vaporized by the passage of current, yielding gas phase solutes that are subsequently ionized in the < 5 W (maximum of 60 mA and 500 V), ~1 mm3 volume, plasma. The LS-APGD is mounted in place of the normal electrospray ionization source of a Thermo Scientific Exactive orbitrap mass spectrometer system. Basic operating characteristics are described, including the role of discharge power on mass spectral composition, the ability to obtain ultra-high resolution elemental isotopic patterns, and preliminary limits of detection attainable based on the injection of aliquots of multielement standards. While much optimization remains, it is believed that the LS-APGD may present a practical alternative to high-powered (>1 kW) plasma sources typically employed in elemental mass spectrometry, particularly for those cases where costs, operational overhead, and simplicity considerations are important.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Diurnal Rhythms Result in Significant Changes in the Cellular Protein Complement in the Cyanobacterium Cyanothece 51142

Cyanothece sp. ATCC 51142 is a diazotrophic cyanobacterium notable for its ability to perform oxygenic photosynthesis and dinitrogen fixation in the same single cell. Previous transcriptional analysis revealed that the existence of these incompatible cellular processes largely depends on tightly synchronized expression programs involving ,30% of genes in the genome. To expand upon current knowledge, we have utilized sensitive proteomic approaches to examine the impact of diurnal rhythms on the protein complement in Cyanothece 51142. We found that 250 proteins accounting for,5% of the predicted ORFs from the Cyanothece 51142 genome and 20% of proteins detected under alternating light/dark conditions exhibited periodic oscillations in their abundances. Our results suggest that altered enzyme activities at different phases during the diurnal cycle can be attributed to changes in the abundance of related proteins and key compounds. The integration of global proteomics and transcriptomic data further revealed that post-transcriptional events are important for temporal regulation of processes such as photosynthesis in Cyanothece 51142. This analysis is the first comprehensive report on global quantitative proteomics in a unicellular diazotrophic cyanobacterium and uncovers novel findings about diurnal rhythms.

59 BASIC BIOLOGICAL SCIENCES↗

First Distance-of-Flight Instrument: Opening A New Paradigm in Mass Spectrometry

Operation of the first distance-of-flight mass spectrometry (DOFMS) instrument is demonstrated. DOFMS measures the mass-to-charge ratio of ions based upon the distance each ion travels during a fixed time period, and records a mass spectrum with a position-sensitive detector. Initial results are demonstrated with a glow discharge source for atomic ion determination.

74 ATOMIC AND MOLECULAR PHYSICS↗

Evaluation of a fourth-generation focal plane camera for use in plasma-source mass spectrometry

A fourth-generation focal plane camera containing 1696 Faraday-strip detectors was fitted to a Mattauch-Herzog mass spectrograph and characterized for its performance with inductively coupled plasma ionization. The camera provides limits of detection in the single to tens of ng L-1 range for most elements and has a linear dynamic range of at least nine orders of magnitude. Isotope-ratio precision better than 0.02% has also been achieved with this device, and this fourth-generation system features the broadest simultaneous mass range obtainable to date with this family of focal plane camera detectors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization of a third-generation Faraday-strip array detector coupled to a Mattauch-Herzog geometry mass spectrograph with a dc-glow discharge ionization source

A third-generation Faraday-strip array detector has been coupled to a Mattauch-Herzog mass spectrometer and dc glow-discharge ionization source. This combination offers simultaneous determination of multiple elements directly from solid samples and provides superior resolving power and improved limits of detection over previous generations of array detectors. With the thirdgeneration detector array, resolving power is limited only by the mass spectrometer and not by the array. Because of this enhanced resolution, limits of detection, especially for higher mass-to-charge ratios, were improved. Isotope-ratio precision was found to be 0.07% RSD on average and quantitative response was linear over 5 orders of magnitude.

47 OTHER INSTRUMENTATION↗

Evaluation of a 512-Channel Faraday-Strip Array Detector Coupled to an Inductively Coupled Plasma Mattauch-Herzog Mass Spectrograph

A 512-channel Faraday-strip array detector has been developed and fitted to a Mattauch-Herzog geometry mass spectrograph for the simultaneous acquisition of multiple mass-to-charge values. Several advantages are realized by using simultaneous detection methods, including higher duty cycles, removal of correlated noise, and multianalyte transient analyses independent of spectral skew. The new 512-channel version offers narrower, more closely spaced pixels, providing improved spectral peak sampling and resolution. In addition, the electronics in the amplification stage of the new detector array incorporate a sample-and-hold feature that enables truly simultaneous interrogation of all 512 channels. While sensitivity and linear dynamic range remain impressive for this Faraday-based detector system, limits of detection and isotope ratio data have suffered slightly from leaky p-n junctions produced during the manufacture of the semiconductor-based amplification and readout stages. This paper describes the new 512-channel detector array, the current dominant noise sources, and the figures of merit for the device as pertaining to inductively coupled plasma ionization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Use of an ambient ionization flowing atmospheric-pressure afterglow source for elemental analysis through hydride generation

An ambient mass spectrometry ionization source based on an atmospheric-pressure flowing afterglow has been coupled to a Mattauch-Herzog mass spectrograph capable of simultaneous acquisition of a range of mass-to-charge values by means of a Faraday-strip array detector. The flowing afterglow was used as the ionization pathway for species produced by hydride generation. This ionization strategy circumvents problems, such as discharge instabilities or memory effects, induced by introducing the gaseous sample into the discharge. The generated spectra show both atomic and molecular peaks; calibration curves were calculated for both peak types with limits of detection for arsenic below 10 ppb. This study demonstrates the ability to use an ambient mass spectrometry source, commonly used for molecular analyses, for the detection of gas phase elemental species with the possibilty of performing speciation by coupling with a separation technique.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Continuous Simultaneous Detection in Mass Spectrometry

In mass spectrometry, several advantages can be derived when multiple mass-to-charge values are detected simultaneously. One such advantage is an improved duty cycle, which leads to superior limits of detection, better precision, shorter analysis times, and reduced sample sizes. A second advantage is the ability to reduce correlated noise by taking the ratio of two or more simultaneously collected signals, enabling greatly enhanced isotope ratio data. A final advantage is the elimination of spectral skew, leading to more accurate transient signal analysis. Here, these advantages are demonstrated by means of a novel Faraday-strip array detector coupled to a Mattauch-Herzog mass spectrograph. The same system is used to monitor elemental fractionation phenomena in laser ablation inductively coupled plasma mass spectrometry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗